Q-i GE NucIcar Energy October 26,1990
~
MFN No.134 90 Docket No. STN 50 605 EEN 9063 Document Control Desk i
U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention:
Charles L. Miller, Director Standardization and Non Power Reactor Project Directorate
Subject:
Submittal of Responses to Additional Information as Requested in NRC Letter from Dino C. Scaletti, Dated May 4,1990 and Related Clarifications
Reference:
1.
Submittal of Responses to Additional Information as Requested in NRC Letter from Dino Scaletti, MFN No.
075 90, dated June 29,1990 j
2.
Submittal of Amendment 6 to GE's ABWR SSAR, MFN No. 25 89, dated March 31,1989
Dear Mr. Miller:
I Enclosed are thirty four copies of revised Chapter 11 responses to Questions 430.157 and 430.165b to the subject Request for AdditionalInformation (RAl) on the Standard Safety Analysis Report (SSAR) for the Advanced Boiling Water Reactor (ABWR). The initial response to these questions was provided in Reference 1. Also included are clarifications pertaining to onsite radwaste storage and SSAR modifications explaining the offgas two-stage cochng system.
Please note that this material contains information that is designated as General Electric Company proprietary information. This material relates to the Chapter 11 proprietary information that was previously sent to the NRC via Reference 2 and its corresponding proprietary affidavit.
It is intended that GE will amend the SSAR with these responses in a future amendment.
Sincerely,
/
P.W. Marriott, Manager Regulatory and Analysis Services ec:
F.A. Ross (DOE)
D.C. Scaletti (NRC)
T. Chandrasekaran (NRC)
}
gM ge$g Y gge fp4 D.R. Wilkins (GE)
,o J.F. Quirk (GE) f4 90110 9211 901026 PDR nDOCK 05000605 g