NOV i 5 1993

Docket Nos. 50-413, 50-414

License Nos. NPF-35, NPF-52

Duke Power Company

ATTN: Mr. D. L. Rehn

Site Vice President

Catawba Site

4800 Concord Road

York, SC 29745-9635

Gentlemen:

SUBJECT:

NRC EXAMINATION REPORI N0. 50-413/93-301

This refers to the Nuclear Regulatory Commission (NRC) administered examina-

tions led by Michael E. Ernstes on October 21, 1993. The examinations were

administered to employees of your company who currently hold licenses to

operate the Catawba Nuclear Plant. These operators had failed the requalifi-

cation examination administered in May 1993. At the conclusion of the

examination, the examinations and preliminary findings were discussed with

those members of your staff identified in the NRC Examination Report,

Enclosure 1.

A copy of the written examination questions and answer key, as noted in

Enclosure 2, was provided to members of your training staff at the conclusion

of the examination.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and the enclosures will be placed in the NRC Public Document Room.

Should you have any questions concerning this examination, please contact us.

.

Sincerely,

OMGUIS!cNEin;y T. A.PEEBLES

Thomas A. Peebles, Chief

Operations Branch

Division of Reactor Safety

,

Enclosures:

1.

NRC Examination Report No. 50-321/93-301

2.

Written Examination and Answer

Key (Document Control Desk Only)

cc w/ encl 1:

(See page 2)

220046

9312010363 931115

k

PDR

ADOCK 05000413

,

j

,

-

-

,

.

.

Georgia Power Company

2

cc w/ encl 1:

R. C. Futrell, Compliance

.

Duke Power Company

,

4800 Concord Road'

York, SC 29745-9635

,

A. V. Carr, Esq.

Duke Power Company

422 South Church Street

Charlotte, NC 28242-0001

J. Michael McGarry, III, Esq.

Winston and Strawn

1400 L Street, NW

Washington, D. C.

20005

North Carolina MPA-1

Suite 600

P. O. Box 29513

Raleigh, NC 27626-0513

Max Batavia, Chief

Bureau of Radiological Health

S. C. Department of Health

and Environmental Control

2600 Bull Street

Columbia, SC 29201

Richard P. Wilson, Esq.

Assistant Attorney General

S. C. Attorney General's Office

P. O. Box 11549

Columbia, SC 29211

Michael Hirsch

-

Federal Emergency Management Agency

500 C Street, Sw, Room 840

Washington, D. C.

20472

North Carolina Electric

Membership. Corporation

P. O. Box 27306

Raleigh,~ NC 27611

,

Karen E. Long

Assistant Attorney General

N. C.-Department of Justice

P. O. Box 629

Raleigh, NC 27602

cc w/ encl I cont'd:

(See page 3)

.

-

-

=

=

,

_ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _

_ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ . ..

,

-

.

,

,

NOV l 51993

Georgia Power Company

3

cc w/ encl I cont'd:

J

Saluda River Electric

'

Cooperative, Inc.

P. O. Box 929

I

I.

Laurens, SC 29360

T. Richard Puryear

Nuclear Technical Services Manager

Carolinas District

i

Westinghouse Electric Corporation

2709 Water Ridge Parkway, Ste. 430

Charlotte, NC 28217

l

l

County Manager of York County

York County Courthouse

York, SC 29745

!

Piedmont Municipal Power Agency

l

121 Village Drive

l

Greer, SC 29651

G. A. Copp

Licensing - EC050

Duke Power Company

P. O. Box 1006

Charlotte, NC 28201-1006

J. D. Wylie

Training Manager

Catawba Nuclear Station

4850 Concord Road

York, SC 29745

bec M/ encl 1:

R. E. Hartin, NRR

R. Gallo, NRR

A. Gibson, DRS

W.-Miller, DRP

J. Jaudon, DRS

G. Hallstrom, DRS

A. R. Herdt, DRP

M. S. Lesser, DRP

L. Lawyer, DRS

R. Aiello, DRS

M. Ernstes, DRS

bcc w/ encl I cont'd:

(See page 4)

_ _ - _ _ - _ _ - _ _ _ _ _ _ _

j

. - .

-

.-

_ ..

-

. .

.

.

NOV I 51993

Georgia Power Company

4

.

bec w/ encl I cont'd:

NRC Resident Inspector

U.S.-Nuclear Regulatory Commission

Route 2, Box 179-N

York, SC 29745

bec w/encls 1 and 2:

Document Control Desk

bcc w/o encls:

IMS, Region 11

't

f

RII:D S

RII

S

RII:DRP

D,RS7

es:me/fr - Llawyer

$3ffbLesser

TPeeb es

[9'MErn

11/ff93

ll/I+/93

11//7./93

6

ll/i /93

/

Document name: g:\\l a\\ catawba \\r30lrpt.mee