i November 18, 1993 Docket No. 50-325

'l MEMORANDUM FOR:

S. Singh Bajwa Project Directorate 11-1 j

Division of Reactor Projects - I/II FROM:

Patrick D. Milano, Senior Project Manager Project Directorate II-1 Division of Reactor Projects - I/II

SUBJECT:

FORTHCOMING MEETING WITH CAROLINA POWER & LIGHT COMPANY - BRUNSWICK STEAM ELECTRIC PLANT, UNIT 1 (TAC NO. M87270)

DATE & TIME:

November 30, 1993 1:00 - 4:00 p.m.

LOCATION:

U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, Maryland Room 1/F/19 PURPOSE:

To discuss the evaluation of core shroud cracks and safety analysis for the design of repair modification.

PARTICIPANTS *:

b1G C_PIL P

J. Strosnider R. Grazio S. Bajwa G. Miller W. Koo J. Purkis J. Medoff V. Wagoner R. Frahm G. Honma P. Milano K. Harris ORIGINAL SIGNED BY B. L. SIEGEL FOR Patrick D. Milano, Sr. Project Manager Project Directorate 11-1 Division of Reactor Projects - I/II cc: See next page CONTACT:

Patrick D. Milano 504-1457

  • Meetings between NRC technical staff and applicants or licensees are open for interested members'of the public, petitioners, intervenors, or other parties to attend as observers pursuant to "Open Meeting Statement of NRC Staff Policy," 43 Federal Reaister 28058, 6/28/78.

OFC LA>PODt -

PM:PDII-1_ o D:PDII-#1/

l NAME PAnNr7on PMila[Nfg SBajwak DATE

// / II. /93

/// /b3

// / /fi93 0FFICIAL RECORD COPY l

DOCUMENT NAME: G:\\BRUNSWIC\\BR87270.MTR NBC BLE CENTS C8PY i 0 ju2%N3Mb g01

DISTRIBUTION - Routine Meetina Notice Dated November 18, 1993 WDocket? File; NRC & Local PDRs PD 11-1 R/F T. Murley/F. Miraglia L. J. Callan, Acting S. Varga G. Lainas J. Wiggins B. D. Liao S. Bajwa P. Milano P. Anderson B. Grimes A. Chaffee, OEAB OGC E. Jordan E. Rossi Receptionist (0WFN)

J. Strosnider W. Koo J. Medoff R. Frahm ACRS (10)

OPA NRR Mailroom, PMAS, 12/G/18 G. Zech, RPEB L. Plisco, ED0 E. Merschoff, RII K. Clark, RII cc:

Licensee & Service List i

l i

[pano, u

t UNITED STATES

[

j NUCLEAR REGULATORY COMMISSION

  • 1

'f WASHINGTON. D.C. 20565-0001

\\;......,f November 18, 1993 Docket No. 50-325 MEMORANDUM FOR:

S. Singh Bajwa Project Directorate 11-1 Division of Reactor Projects - I/II FROM:

Patrick D. Milano, Senior Project Manager Project Directorate 11-1 Division of Reactor Projects - I/II

SUBJECT:

FORTHCOMING MEETING WITH CAROLINA POWER & LIGHT COMPANY - BRUNSWICK STEAM ELECTRIC PLANT, UNIT 1 (TAC NO. M87270)

DATE & TIME:

November 30, 1993 1:00 - 4:00 p.m.

LZATION:

U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, Maryland 1

Room 1/F/19 PURPOSE:

To discuss the evaluation of core shroud cracks and safety analysis for the design of. repair modification.

PARTICIPANTS *:

NRC Q&L J. Strosnider R. Grazio S. Bajwa G. Miller W. Koo J. Purkis J. Medoff V. Wagoner R. Frahm G. Honma P. Milano K. Harris M

i P rick D. Mi ano, Sr. Project Manager Project Directorate 11-1 Division of Reactor Projects - I/II cc: See next page CONTACT:

Patrick D. Milano 504-1457

  • Meetings between NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other parties 1

to attend as observers pursuant to "Open Meeting Statement of NRC Staff j

Policy," 43 Federal Reaister 28058,6/28/78.

s Mr. R. A. Anderson Brunswick Steam Electric Plant Carolina Power & Light Company Units 1 and 2 cc:

Mr. Mark S. Calvert Karen E. Long Associate General Counsel Assistant Attorney General Carolina Power & Light Company State of North Carolina Post Office Box 1551 Post Office Box 629 Raleigh, North Carolina 27602 Raleigh, North Carolina 27602 Mr. Kelly Holden, Chairman Mr. Robert P. Gruber

. 1 Board of Commissioners Executive Director Post Office Box 249 Public Staff - NCUC Southport, North Carolina 28422 Post Office Box.29520 Raleigh, North Carolina 27626-0520 Resident Inspector U.S. Nuclear Regulatory Commission Mr. H. W. Habermeyer, Jr.

Star Route 1, Post Office Box 208 Vice President Southport, North Carolina 28461 Nuclear Services Department Carolina Power & Light Company Regional Administrator, Region II Post Office Box 1551 - Mail OHS 7 U.S. Nuclear Regulatory Commission Raleigh, North Carolina 27602 t

101 Marietta St., N.W., Ste. 2900 Atlanta, Georgia 30323 Mr. Dayne H. Brown, Director Division of Radiation Protection N.C. Department of Environmental, Commerce and Natural Resources Post Office Box 27687 Raleigh, North Carolina 27611-7687 r

Mr. J. M. Brown i

Plant Manager - Unit 1 Carolina Power & Light Company Brunswick Steam Electric Plant Post Office Box 10429 Southport, North Carolina 28461 Public Service Commission State of South Carolina Post Office Drawer 11649 Columbia, South Carolina 29211 Mr. C. C. Warren Plant Manager - Unit 2 Brunswick Steam Electric Plant Post Office Box 10429 Southport, North Carolina 28461 t

i j

l

,