Provides Suppl Response to NRC Bulletin 93-002, Debris Plugging of ECCS Suction Strainers
ML20057E600
Person / Time
Site: Catawba  
Issue date: 09/30/1993
From: Rehn D
DUKE POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IEB-93-002, IEB-93-2, NUDOCS 9310120349
Download: ML20057E600 (2)


Text

u 11 1

Duke Four Company DLRon Cutawba kdear Generanon [+;w: ment

\\he hesidert!

4% ConcordIbad (b93)DI3205 Omce york SC29743 1M3)DI3426 Fax DUKEPOWER September 30,1993 U.S. Nuclear Regulatory Commission A1TN: Document Control Desk Washington, D.C. 20555

Subject:

Catawba Nuclear Station Docket Nos. 50-413 and 50-414 NRC Bulletin 93-02, Debris Plugging of Emergency Core Cooling Suction Strainers Supplemental Response By Duke Power Company supplemental response dated September 16,1993, Catawba Nuclear Station described compensatory measures to be implemented on Unit 2 to reduce the probability for debris plugging of the ECCS Suction Strainers. The implementation of these compensatory measures were to be in effect by October 30,1993, and remain in effect until the removal of the Containment Air Charcoal Filter Units (CACFUs) from Unit 2 containment.

This supplemental response serves as notice that the CACFU pre-filters and high efficiency particulate adsorbers (HEPAs) were removed from Unit 2 containment on September 25,1993, during a Unit 2 forced outage. Accordingly, the planned compensatory measures which were to be in effect by October 30, 1993, have been canceled. Work orders to remove the Unit 1 CACFU pre-filters and HEPA filters during the next forced / refueling outage remain in place.

I declare under penalties of perjury that the statements set forth herein are true and correct to the best of my knowledge.

{i,

D.L. Rehn, Site Vice-President Catawba Nuclear Station 9310120349 930930 4$N PDR ADOCK 05000413 l

S if PDR t.

s nr..

r,

U.S.' Nuclear Regulatory Commission September 30,1993 Page 2 xe:

S.D. Ebneter Regional Administrator, Region 11 R.E. Martin, ONRR R.J. Freudenberger Senior Resident Inspector

-