October 4, 1993 Docket No. 50-395 Mr. John L. Skolds, Vice President l

Nuclear Operations South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station I

Post Office Box 88 Jenkinsville, South Carolina 29065

{

Dear Mr. Skolds:

SUBJECT:

REVISION TO TECHNICAL SPECIFICATION BASES 3/4.5.4 AND 3/4.6.2.2 REGARDING EMERGENCY CORE COOLING AND CONTAINMENT SYSTEMS -

VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 (TAC NO. M87192).

By letter dated December 22, 1992, you submitted changes to.the bases of the Technical Specifications (TS) for the Virgil C. Summer Nuclear Station, Unit No. 1.

The changes reduce the low end of the predicted pH range of the water in the reactor building sump following a loss-of-coolant accident from 7.8 to I

7.5.

Enclosed please find the revised bases pages.

Under the provisions of 10 CFR 50.59, the subject revisions did not require review and approval by the staff. The staff may, however, review the associated 10 CFR 50.59 evaluation in a future inspection. This completes the staff's effort on TAC No. M87192.

Sincerely, ORIGINAL SIGNED BY:

George F. Wunder, Project Manager Project Directorate II-1 Division of Reactor Projects - I/II l

Office of Nuclear Reactor Regulation

Enclosure:

Revised Bases Pages cc w/ enclosure:

See next page DISTRIBUTION:

7 Docket File S. Bajwa G. Hill (2)

E. Merschoff, RII NRC & Local PDRs P. Anderson C. Grimes PDII-1 R/F G. Wunder ACRS (10)

S. Varga OGC OPA G. Lainas D. Hagan OC/LFDCB LA:PAdhPE PM:PD21:DRPE D:PD21:DRPE 0FFICE NAME pan N GWd'd[r:rst SBajwa Nk h///93 (Jf/,26/93 9/d/93 DATE 0FFICIAL RECORD COPY DOCUMENT NAME: G:\\ SUMMER \\ SUM 87192.LTR hf 9310000164 931004 k

l PDR ADOCK 05000395

.\\

I P

PDR.

\\

L p[in arc o

i q

UNITED STATES -

E NUCLEAR REGULATORY COMMISSION Ia

'f WASHINGTON, D.C. 20566 4 001 o,

f October 4, 1993 Docket No. 50-395 j

Mr. John L. Skolds, Vice President

\\

Nuclear Operations.

i South Carolina Electric & Gas Company j

Virgil C. Summer Nuclear Station Post Office Box 88 Jenkinsville, South Carolina 29065

Dear Mr. Skolds:

i

SUBJECT:

REVISION TO TECHNICAL SPECIFICATION BASES 3/4.5.4 AND 3/4.6.2.2 i

REGARDING EMERGENCY CORE COOLING AND CONTAINMENT SYSTEMS -

i l

VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 (TAC NO. M87192).

i By letter dated December 22, 1992, you submitted changes to the bases of the l

Technical Specifications (TS) for the Virgil C. Summer Nuclear. Station, Unit No. 1.

The changes reduce the low end of the predicted pH range of the water in the reactor building sump following a loss-of-coolant accident from 7.8 to 7.5.

Enclosed please find the revised bases pages.

i Under the provisions of 10 CFR 50.59, the subject revisions did not require i

review and approval by the staff. The staff may, however, review the associated 10 CFR 50.59 evaluation in a future inspection.

This completes the staff's effort on TAC No. M87192.

Sincerely,

.hff Y A

1 i

George F. Wu'nder, Project Manager Project Directorate II-I Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation l

Enclosure:

l Revised Bases Pages l

cc w/ enclosure:

See next page 1

l-l l

Mr. John L. Skolds -

Virgil C. Sumer Nuclear Station South Carolina Electric & Gas Company i

cc:

Mr. R. J. White Nuclear Coordinator j

S.C. Public Service Authority c/o Virgil C. Sumer Nuclear Station Post Office Box 88, Mail Code 802 Jenkinsville, South Carolina 29065 J. B. Knotts, Jr., Esquire Winston & Strawn Law Firm 1400 L Street, N.W.

Washington, D.C.

20005-3502 Resident Inspector /Sumer NPS c/o U.S. Nuclear Regulatory Commission j

Route 1, Box 64 Jenkinsville, South Carolina 29065 l

Regional Administrator, Region II U.S. Nuclear Regulatory Comission 101 Marietta St., N.W., Ste. 2900 Atlanta, Georgia 30323 Chairman, Fairfield County Council Drawer 60 Winnsboro, South Carolina 29180 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 1

2600 Bull Street Columbia, South Carolina 29201-Mr. R. M. Fowlkes, Manager Nuclear Licensing & Operating Experience South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88 Jenkinsville, South Carolina 29065

-.. -