Forwards Final SALP Rept 50-346/93-01 for Period of 911201- 930630
ML20057D362
Person / Time
Site: Davis Besse 
Issue date: 09/24/1993
From: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Storz L
CENTERIOR ENERGY
Shared Package
ML20057D363 List:
References
NUDOCS 9310040145
Download: ML20057D362 (3)


See also: IR 05000346/1993001

Text

.

I

SEP 2 41993

.

Docket No. 50-346

Centerior Service Company

ATIN: Mr. Louis F. Storz

Vice President

Nuclear - Davis-Besse

c/o Toledo Edison Company

300 Madison Avenue

Toledo, OH 43652

Dear Mr. Storz:

This refers to the NRC's Systematic Assessment of Licensee Performance

-

(SALP) 10 Report for the Davis-Besse Nuclear Power Station, our meeting of

t

September 16, 1993, in which we discussed in detail the contents of the

report, and your letter of respon:e dated September 23, 1993, relative to the

.i

report.

l

Based on our discussions during the meeting and our review and evaluation.of

I

your letter of response, we have reached the conclusions presented in the

4

enclosed meeting summary. Several specific concerns were discussed, including

those involving personnel errors (particularly in the operations area),

control room noise levels, and contamination control problems encountered

during your most recent refueling outage. During our discussion, you and your

staff committed to certain followup actions which are also described in the

meeting summary.

If your understanding differs from that described, please

contact us immediately.

!

With the incorporation of the revised pages from Enclosure 3, the initial SALP.

.

t

report, dated August 27, 1993, should be considered the final SALP. report.

,D ,

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,

i

Title 10, Code of Federal Regulations, a copy of this letter with the

s'j

,

,

referenced enclosures, will be placed in the NRC's Public Document Room.

l

'

P

,

I

!

!

_

.

9310040145 930924

,

PDR

ADOCK 05000346

.t

G

PDR

i

-

_ _ _ - _ _ _ _ _ _ _ _ - _

_ - _ _

_ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -

SEP 2 41993 '

'

Toledo Edison Company

2

~

.

'

No reply to this letter is required, however, should you have any questions

concerning the final SALP report, we would be pleased to discuss them with

you.

Sincerely,

t

ORIGINAL SIGNED BY HIJBERT J. MILLER

.@JohnB. Martin,

"

Regional Administrator

Enclosures:

1

1.

Final SALP 10 Report

No. 50-346/93001 (Meeting Summary)

2.

Meeting Handouts

3.

Revision Sheet

'

4.

Revised Pages to SALP Report

5.

Licensee Response Letter, Dated 9/23/93

cc w/ enclosures:

J. K. Wood, Plant Manager

W. T. O'Connor, Manager

Regulatory Affairs

D. C. Shelton, Senior Vice President-

Nuclear

State Liaison Officer, State

of Ohio

Robert E. Owen, Ohio

Department of Health

A. Grandjean, State of Ohio,

.

Public Utilities Commission

l

OC/LFDCB

Resident Inspector, RIII

Licensing Project Manager, NRR

INP0

See Continued Distributita

(b

RIII

RIII

RIII

R

RIII

RIII DD

)

Gnhl2fu

fr2 & A w/ig 4M/Lgk

LaTop/c

Gr% *'n

i

,cco

Lanksbury

McCormick-Barger Hassel

reger

i

e

eent

RI

RIII

RIII,

RIII

% f RIII

'A

') '

ny

Tla tin

A

n

J

(

y

e

(gv

%4

1

_

.

.

'

-

Toledo Edison Company

3

SEP 2 41913

'

Continued Distribution

The Chairman

Commissioner Rogers

,

Commissioner Remick

Commissioner de Planque

J. H. Sniezek, DEDR

T. E. Murley, Director, NRR

Chief, RPEB, NRR (2 copies)

J. N. Hannon, NRR Director, Project Directorate III-3

J. Lieberman, Director, Office of Enforcement

C. D. Pederson, RIII

L. L. Cox, RIII (2 copies)

-

TSS, RIII

,

RIII Files

RIII PRR

'

'

'

bcc: PUBLIC

,

i

i

e

I

i