Forwards Application for Amend to License NPF-69,changing Index,Table 1.2, Operational Conditions, Section 3/4.10, Special Test Exception, & Bases
ML20057C808
Person / Time
Site: Nine Mile Point 
Issue date: 09/28/1993
From: Sylvia B
NIAGARA MOHAWK POWER CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20057C809 List:
References
NMP2L-1447, NUDOCS 9309300056
Download: ML20057C808 (2)


Text

_ _ _ _ _. _ _ _ _ - - - - - - _ - _ _ _ _ _ - - - - - - _ - _ _ _ _.

RLI V N IA G A R A 61 UMOHAWK NIAGARA MOHAWK POWER CORPoRATloN'NINE MILE POINT. Po. BOX 63. LEOMING. NY 13093/ TELEPHONE (315) 349-2882 B. Ralph SyMa September 28, ]993 Ee e Vice President U. S. Nuclear Regulatory Commission Attn: Document Control Desk E

Washington, D. C. 20555 Re: Nine Mile Point Unit 2 Docket No. 50-410 NPF-69 Gentlemen:

Niagara Mohawk Power Corporation hereby transmits an Application for Amendment to Nine Mile Point Unit 2 Operating License NPF-69. Also enclosed are the proposed changes to the Technical Specifications set forth in Appendix A of the above mentioned license.

Supporting information and analyses demonstrating that the proposed changes involve no significant hazards consideration pursuant to 10 CFR 50.92 are included as Attachment B.

This letter supersedes in its entirety our previous Application for Amendment dated May 7, 1993 (NMP2L 1383).

The proposed Technical Specification changes contained herein represent changes to the Index, Table 1.2, " OPERATIONAL CONDITIONS," Section 3/4.10, "Special Test Exceptions," and the Bases. The addition of Specification 3/4.10.7, " Inservice Leak and Hydrostatic Testing," permits remaining in OPERATIONAL CONDITION 4 with reactor coolant temperatures up to 212 F to facilitate inservice leak and hydrostatic testing. The proposed changes require that secondary containment, which includes automatic isolation dampers and the Standby Gas Treatment System, be operable.

The proposed changes contained in our May 7,1993 Application were based on the

" Improved Standard Technical Specifications," NUREG-1433, dated September 28,1992, which contain no limit on reactor coolant temperatures for hydrostatic and leak testing during OPERATIONAL CONDITION 4. During review of the Application, the Staff expressed concerns about the lack of a temperature limit in NUREG-1433 and the consequences of a postulated leak or pipe break at elevated temperatures during hydrostatic or leak testing. In lieu of addressing a pipe break at elevated temperatures, we propose a temperature limit of 212 F during hydrostatic and leak testing in OPERATIONAL CONDITION 4. The flexibility provided by this proposed amendment is required to support the upcoming g

refueling outage, scheduled to start on October 1,1993. Therefore, Niagara Mohawk is CO withdrawing its request for adoption of the NUREG-1433 provision and is instead submitting C

a request for a plant specific Technical Specification change in co The Inservice Leakage or Hydrostatic Test is a critical path test in the refueling outage I

9309300056 930928

.l PDR ADOCK 05000410 (I

P PDR n

-Document Control Desk Page 2 schedule. Therefore, to minimize impact on the refueling outage schedule, Niagara Mohawk i

requests that the enclosed Application be given a priority review in order to effect the desired changes.

a Pursuant to 10 CFR 50.91(b)(1), Niagara Mohawk has provided a copy of this license amendment request and the associated analyses regarding no significant hazard considerations to the appropriate state representative.

Very truly yours,-

l Mz/

b B. Ralph Sylvia Exec. Vice President - Nuclear i

MGM/Imc f

003576LL Enclosures xc:

Mr. T. T. Martin, Regional Administrator, Region I Mr. B. S. Norris, Senior Resident Inspector Mr. R. A. Capra, Director, Project Directorate I-1, NRR Mr. J. E. Menning, Project Manager, NRR Ms. Donra Ross Division of Policy Analysis and Planning New York State Energy Office Agency Building 2 Empire State Plaza Albany, NY 12223 Records Management t