Amend 196 to License DPR-59,revising TS 4.7.A.2.f to Eliminate Requirement to Perform Type A,B or C Leak Rate Test Following Completion of Planned Repairs to Sections of Core Spray Sys Min Flow Lines
ML20057A654
Person / Time
Site: FitzPatrick 
Issue date: 08/30/1993
From: Menning J
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20057A655 List:
References
NUDOCS 9309150107
Download: ML20057A654 (4)


Text

.

f[

'o UNITED STATES g

y g

NUCLEAR REGULATORY COMMISSION 7;

p WASHINGTON D. C. 20555 1.,...../

J POWER AUTHORITY OF THE STATE OF NEW YORK DOCKET NO. 50-333 JAMES A. FITZPATRICK NUCLEAR POWER PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendmert No. 196 License No. DPR-59 1.

The Nuclear Regulatory Commission (the Commission) has found thst:

A.

The application for amendment by Power Authority of the State of New York (the licensee) dated June 28, 1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the licer.se is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-59 is hereby amended to read as follows:

9309150107 930830 PDR ADOCK 05000333 P

PDR

. (2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No.196, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

l 3.

This license amendment is effective as of the date of its issuance to be implemented within 30 days.

FOR THE NUCLEAR REGULATORY COMMISSION Y 0. f Robert A. Capra, Director Project Directorate I-l Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance: August 30, 1993 l

l s

m

ATTACHMENT TO LICENSE AMENDMENT NO. 196 FACILITY OPERATING LICENSE NO. DPR-59 DOCKET NO. 50-333 Revise Appendix A as follows:

Remove Paae Insert Pace 174 174

JAFNPP 4.7 (cont'd)

(5)

Type C test.

Type C tests shall be performed during each reactor shutdown for refueling but in no case at intervals greater than two years.

(6)

Other leak rate tests specified in Section 4.7.d shall be performed during each reactor shutdown for refueling but in no case at intervals greater than two years.

f.

Containment modification

  • l Any major modification, replacement of a component which is part of the primary reactor containment boundary, or resealing a seal-welded door, performed after the preoperational leakage rate test shall be followed by either a Type A, Type B, or Type C test, as applicable, for the area affected by the modification. The measured leakage from this test shall be included in the test report. The acceptance criteria as appropriate, shall be met. Minor modifications, replacements, or resealing of seal-welded doors, performed directly prior to the conduct of a scheduled Type A test do not require a separate test.
  • In accordance with an exemption from 10 CFR 50 Appendix J, a Type A, B. or C test is not required for the replacement of piping and welds which constitute the Core Spray System minimum flow lines (3"-

W23-152-7A, B) during the 1993 maintenance outage.

Amendment No. ed,9f,126,124,1M, J,96,196 174

.