O May 20, 1993 0 MEMORANDUM FOR:
Commissioner Rogers FROM:
James M. Taylor Executive Director for Operations
SUBJECT:
RESPONSE TO YOUR LETTER OF MAY 5, 1993, CONCERNING CORE DEBRIS C00 LABILITY FOR ADVANCED LIGHT-WATER REACTORS We agree that the staff should analyze the depth of core melt penetration as well as gaseous reactant products for the advanced light-water reactors (ALWRs). To accomplish this, the staff has initiated contracts with the national. labs to analyze the affect of core concrete interaction on i
containment performance by using NRC computer models, such as MELCOR. The results of these analyses will be documented in the final safety evaluation j
reports for the particular designs.
Combustion Engineering and General Elec'tric have performed such analyses using the industry's computer model MAAP. We would expect these results to show that the containment can maintain'its role as a reliable, leak-tight barrier for approximately 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> following the onset of core damage.
It is the J
staff's intention to perform sensitivity studies and assess these analyses during the performance of the above mentioned contract.
.)
l Originalsigned by James H.Snlezek j
James M.-Taylor '
Executive Director for Operations cc: The Chairman Distribution Commissioner Curtiss Central files HThompson Commissioner Remick PDR JB1aha i
Commissioner de Planque SCSB R/F EBeckjord, RES SECY MSnodderly.
SCSB File (9.1)
OGC JKudrick G12 18 GT0008865 OPA RBarrett OCA AThadani WRussell TMurley JTaylor JSniezek l.
- SEE PREVIOUS CONCURRENCE
- Tech'Ed: 5/7/93 I
- SCSB
- SC:SCSB
- BC:SCSB
- D:DSSA
- ADT
- NRR Snodderly JKudrick RBarrett AThadani WRussell TMurley pylor i
5/7/93 5/7/93 5/7/93 5/7/93 5/7/93 5/13/93 j IJ/93 i
DocumentName:A:\\ Rogers.CC113QQQf Mj$"
k,b- @,. f.}u n..
l NRC FILE CMER USPV go,z Q"'
y 9308260269 930520" j$b l
C$RES E
E PDR
'(C Y
W l'itW Q,y,7.q p ;>'Q{l{
t.
t.
DUN g.
UNITED STATES (i
h !.
i [ *d "8vg NUCLEAR REGULATORY COMMISSION o,,
x 4 W ASHINGTON, D. C. 20555 c,
EDO Principal Correspondence Control E
{
c
\\, * *
- e /
EDO CONTROL: 0008865 DUE: 05/13/93 DOC DT: 05/05/93 FROM:
FINAL REPLY:
^ ^ ;, g7
/
g.gir' # "#""
t
/I" O ^ M 4 Q' I }I lL <</ 9 3 Commissioner Rogers
}' y dtm g
TO:
James M. Taylor CRC NO:
- PRI FOR SIGNATURE OF:
Executive Director ROUTING:
DESC:
Taylor ACRS REVIEW OF STAFF POSITIONS ON SECY-93-087, Sniezek AND LICENSING ISSUES Thompson
" POLICY, TECHNICAL, B1aha PERTAINING TO EVOLUTIONARY AND ADVANCED LIGHT-WATER REACTOR (ALWR) DESIGNS" Beckjord, RES DATE: 05/05/93 J
M;~
/
CONTACT:
'l#
'fr l
ASSIGNED TO:
Mur1ey NRR
&ku
/
SPECIAL INSTRUCTIONS OR REMARKS:/
6 7f
[n. kN
. Ir,.
,/.-
v REF. EDO 8828.
/
\\.
?
t/
NRR RECEIVED: MAY 5,1993 NRR ACTION:
CRUTCHNEtD2AR TEN NRR ROUTING:
FJM JP-
___~
'WR
^^
SC) l TG NRR MAIL ROOM
_..,. J RCE 7
O
)
i,
/
/
- ' - ~ -
.