Text
- _ _ _ _ _ _
_
.
,
.
MAR 2 5 r
Docket Nos. 50-325, 50-324
Carolina Power and Light Company
ATTN: Mr. R. A. Watson
Senior Vice President
Nuclear Generation
P. O. Box 1551
Raleigh, NC 27602
Gentlemen:
SUBJECT: NOTICE OF VIOLATION
(NRC INSPECTION REPORT NOS. 50-325/93-08 AND 50-324/93-08)
This refers to the inspection conducted by G. Wiseman of this office on
February 22-26, 1993. The inspection included a review of activities autho-
rized for your Brunswick I and 2 facility. At the conclusion of the inspec-
tion, the findings were discussed with those members of your staff identified
in the enclosed report.
Areas examined during the inspection are identified in the report. Within
these areas, the inspection consisted of selective examinations of procedures
and representative records, interviews with personnel, and observation of
activities in progress.
Based on the results of this inspection, certain of your activities appeared
to be in violation of NRC requirements, as specified in the enclosed Notice of
Violation (Notice). The violation was cited because you did not
hydrostatically test fire protection piping in accordance with your design
specifications or the applicable National Fire Protection Association stan-
dards. The inspection also revealed that fire protection procedures had not
I
been updated to reflect facility and organizational changes. A Nuclear
Assessment Department audit in October 1992, identified similar problems and
the need for increased management attention in the fire protection area.
You
are requested to include in your response to the enclosed Notice, action taken
and planned to strengthen management control over the fire protection area.
You are required to respcad to this letter and should follow the instructions
specified in the enclosed Notice when preparing your response.
In your
response, you should document the specific actions taken and any additional
actions you plan to prevent recurrence. After reviewing your response to this
Notice, including your proposed corrective actions and the results of future
inspections, the NRC will determine whether further NRC enforcement action is
necessary to ensure compliance with NRC regulatory requirements.
9303300196 930325
ADOCK 05000324
G
\\
150l
_
_
. .
.__
_ _ _ _
_ _ _ _
.-
. *
Carolina Power & Light Co.
2
MAR 2 5
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of
this letter and its enclosure will be placed in the NRC Public Document Room.
Sincerely,
/
(.)
Albert F. Gibson, Director
Division of Reactor Safety
Enclosure:
1.
2.
NRC Inspection Report
cc w/encls:
R. A. Anderson
Vice President
Brunswick Nuclear Project
P. O. Box 10429
Southport, NC 28461
R. E. Morgan
Plant Manager Unit 1
Brunswick Steam Electric Plant
P. O. Box 10429
,
Southport, NC 28461
'
M. Brown
Plant Manager Unit 2
Brunswick Steam Electric Plant
P. O. Box 10429
Southport, NC 28461
Mr. Mark S. Calvert
Associate-General Counsel
Brunswick Steam Electric Plant
P. O. Box 10429
Southport, NC 28461
Kelly Holden
Board of Commissioners
P. O. Box 249
' Bolivia, NC 28422
,
(cc w/encls cont'd - See page 3)
'
---___-_
_
_-
.
. . . . . . ..
..
,.
..
.. ..
_. - - - _ - - - - - - _ . - . - - - - . .
.-
..
E A' b 5
Carolina Power & Light Co.
3
(cc w/encls cont'd)
Chrys Baggett
State Clearinghouse
Budget and Management
116 West Jones Street
Raleigh, NC 27603
Dayne H. Brown, Director
Division of Radiation Protection
N. C. Department of Environment,
Health & Natural Resources
P. O. Box 27687
Raleigh, NC 27611-7687
H. A. Cole
Special Deputy Attorney General
State of North Carolina
P. O. Box 629
Raleigh, NC 27602
i%
Robert P. Gruber
g
Executive Director
Public Staff - NCUC
P. O. Box 29520
Raleigh, NC 27626-0520
Ms. Gayle B. Nichols
-Staff Counsel
SC Public Service Commission
P. O. Box 11649
Columbia, SC' 29211
.bec w/encls:
Document Control Desk
H. Christensen, RII
S. Vias, RII
P. Milano, NRR
i
NRC Resident Inspector
i
U.S. Nuclear Regulatory Commission
I
Star Route 1, Box 208
Southport, NC 28461
FILE NAME: S:\\DRS\\EB\\BRU9308L.GW
/.
Rll:DRS
RII RS
RII:DRP
RI
5
GWi
n:pd
Mffrari h
H
ensen
CJulian
03/p/93
03/g/93
03/ 3 /93
03/ /93
f
_-_
-