'mBLE I MINDEM REACTER SAFETY SYS'ITM S3AMS Originating Made in Which Channel.

Set Point Effective SS Pulse 1.

Power level 275 kW or lower X

(2 independent channels)(1)

-.2.

Fuel Element Tenperature As specified in Section 7.4 X

(2 _i % ndent channels)-

or lower 3.

Console Scram-Manual X

X

4. (Facility Power Supply Supply Failure X

X-5.

Magnet Current Key Switch Manual X

X-6.

Watchdog Timer ( )

Software Failure X

X (1) Of the minimum required two independent channels, no nore than one channel shall utilize digital processing of power detector signals.

(2) These scrams are only applicable when ccuputers are utilized -to perfonn -

reactor control functions.

mBIE II MINL4M INIERLOCKS Mode in Which Action Prevented Effective SS Pulse

.--=

1.

Withdrawal of more than one standard rod X

2.

Withdrawal of any standard rod X

3.

Application of air to transient rod unless its movable X

cylinder is fully down M

2$$72h00bk

[