Text

June 24, 2020 Mr. Takayuki Mori, Engineering Manager Global Nuclear Project Department Mitsubishi Heavy Industries, Ltd.

1-1, Wadasaki-Cho 1-Chome Hyogo-Ku Kobe 652-8585 Japan

SUBJECT:

FINAL SAFETY EVALUATION FOR UNITED STATES - ADVANCED PRESSURIZED WATER REACTOR ADVANCED TOPICAL REPORT SAFETY EVALUATION FOR TOPICAL REPORT MUAP-07001-NP, REVISION 7, THE ADVANCED ACCUMULATOR

Dear Mr. Mori:

In a May 2018 submittal (Agencywide Documents Access and Managemement System (ADAMS) Accession No. ML18178A258), Mitsubishi Heavy Industries, Ltd. (MHI), submitted Revision 7 to Topical Report MUAP-07001-NP, The Advanced Accumulator. By letter dated July 29, 2019 (ADAMS Accession No. ML19154A122), the U.S. Nuclear Regulatory Commission (NRC) staff sent you a safety evaluation (SE) with no open items for Topical Report MUAP-07001-NP, Revision 7. The proprietary version of this SE was sent to the Advisory Committee on Reactor Safeguards (ACRS) Subcommittee in advance of a September 19, 2019, meeting.

Following the September 19, 2019, Subcommittee meeting, the ACRS Full Committee meeting discussed the SE for this topical report in their November 6 - 8, 2019, meeting and found the NRC staffs safety findings to be acceptable. Subsequent to the ACRS Full Committee meeting, the ACRS issued a letter dated November 26, 2019 (ADAMS Accession No. ML19331A036), in which they recommended, in part, that the NRC staff issue the SE.

In accordance with the guidance provided on the NRCs TR Web site (http://www.nrc.gov/about-nrc/regulatory/licensing/topical-reports.html), the staff requests that MHI publish an accepted version of this TR within three months of receipt of this letter. The accepted version shall incorporate this letter and the enclosed SE between the title page and the abstract. It must be well indexed such that information is readily located. Also, it must contain in its appendices historical review information such as questions and accepted responses as well as original report pages that were replaced. The accepted version shall include an "-A" (designated accepted) following the report identification symbol.

If the NRCs criteria or regulations change so that its conclusion in this letter (that the TR is acceptable) is invalidated, MHI and/or the applicant referencing the TR will be expected to revise and resubmit its respective documentation or submit justification for the continued applicability of the TR without revision of the respective documentation.

Should you have any questions, please do not hesitate to call. I can be reached at 1+301-415-1494 or via electronic mail at George.Wunder@nrc.gov.

Sincerely,

/RA/

George F. Wunder, Senior Project Manager New Reactor Licenising Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation Docket No.: 52-021

Enclosure:

As stated cc w/o encl.: See next page

PKG: ML20055F683 LETTER: ML20055F976 SER: ML20055F978

  • via e-mail NRR-106 OFFICE NRR/DNRL/NRLB: PM NRR/DNRL/NRLB: LA NRR/DNRL/NRLB: BC NAME GWunder CSmith MDudek DATE 02/24/2020 02/25/2020 06/15/2020 OFFICE NRR/DNRL/NRLB: PM NAME GWunder (signed)

DATE 06/24/2020

DC Mitsubishi - US APWR Mailing List w/o Enclosure Email acpasswater@aol.com (Al Passwater)

APH@NEI.org (Adrian Heymer) atsushi_kumaki@mhi.co.jp (Atsushi Kumaki) awc@nei.org (Anne W. Cottingham) bgattoni@roe.com (William (Bill) Gattoni))

CumminWE@Westinghouse.com (Edward W. Cummins) cwaltman@roe.com (C. Waltman) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis)

DeLaBarreR@state.gov (R. DeLaBarre) donald.woodlan@luminant.com (Donald Woodlan) eliza.seedcoalition@gmail.com (Elza Brown) erg-xl@cox.net (Eddie R. Grant) erin_wisler@mnes-us.com (Erin Wisler) ewallace@nuscalepower.com (Ed Wallace) gcesare@enercon.com (Guy Cesare) hiroki_nishio@mhi.co.jp (Hiroki Nishio) james1.beard@ge.com (James Beard) jerald.head@ge.com (Jerald G. Head)

Joseph_Hegner@dom.com (Joseph Hegner) joseph_tapia@mnes-us.com (Joseph Tapia) jrappe@nuscalepower.com (Jodi Rappe) jrund@morganlewis.com (Jonathan Rund) karlg@att.net (Karl Gross) kevin_lynn@mnes-us.com (Kevin Lynn)

KSutton@morganlewis.com (Kathryn M. Sutton) kwaugh@impact-net.org (Kenneth O. Waugh) lchandler@morganlewis.com (Lawrence J. Chandler) lon.burnam@house.state.tx.us (Lon Burnam) m.goto@mnes_us.com maria.webb@pillsburylaw.com (Maria Webb) mark.a.giles@dom.com (Mark Giles) masanori_onozuka@mnes-us.com (Masanori Onozuka) masatoshi_nagai@mnes-us.com (Masatoshi Nagai) matias.travieso-diaz@pillsburylaw.com (Matias Travieso-Diaz) media@nei.org (Scott Peterson) michael_melton@mnes-us.com (Michael Melton)

MSF@nei.org (Marvin Fertel) nirsnet@nirs.org (Michael Mariotte)

Nuclaw@mindspring.com (Robert Temple) patriciaL.campbell@ge.com (Patricia L. Campbell) paul.gaukler@pillsburylaw.com (Paul Gaukler)

Paul@beyondnuclear.org (Paul Gunter)

Page 1 of 2

DC Mitsubishi - US APWR Mailing List pbessette@morganlewis.com (Paul Bessette) plarimore@talisman-intl.com (Patty Larimore) rebecca_steinman@mnes-us.com (Rebecca Steinman)

RJB@NEI.org (Russell Bell) ryan_sprengel@mnes-us.com (Ryan Sprengel) sabinski@suddenlink.net (Steve A. Bennett) sfrantz@morganlewis.com (Stephen P. Frantz) stephan.moen@ge.com (Stephan Moen) strambgb@westinghouse.com (George Stramback)

Tansel.Selekler@nuclear.energy.gov (Tansel Selekler) tgilder1@luminant.com (Tim Gilder) tmatthews@morganlewis.com (T. Matthews) tom.miller@hq.doe.gov (Tom Miller)

Tony.Robinson@areva.com (Tony Robinson) trsmith@winston.com (Tyson Smith)

Vanessa.quinn@dhs.gov (Vanessa Quinn) vijukrp@westinghouse.com (Ronald P. Vijuk)

Wanda.K.Marshall@dom.com (Wanda K. Marshall) whorin@winston.com (W. Horin) yoshiki_ogata@mhi.co.jp (Yoshiki Ogata)

Page 2 of 2