ML20055E217

From kanterella
Jump to navigation Jump to search
Forwards Requalification Exam Rept 50-454/OL-90-01 for Units 1 & 2 Administered During Wks of 900528 & 0604.Requests Response to Issue of Training & Evaluating Operators on Uncontrolled Depressurization of Steam Generators
ML20055E217
Person / Time
Site: Byron  
Issue date: 07/02/1990
From: Wright G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Reed C
COMMONWEALTH EDISON CO.
Shared Package
ML20055E218 List:
References
NUDOCS 9007110174
Download: ML20055E217 (3)


Text

- _ - _ _ -

Iy l

e

, m..;.,;..

  • ii (

f

1 N "E E Docket No. 50-454>

Docket No. 50-455.

~

Conino'nwealth. Edison Company ATTN:- Mr.:Cordell Reed

.. Senior Vice President m

.JPost Office-Box 767 c

Chicago,--IL 60690

[

Gentlemen:

SUBJECT:

REQUALIFICATION EXAMINATION REPORT During the' weeks of May 28 and June'4, 1990, the NRC' administered-.

requalification examinations to employees of your: organization who operate your. Byron Nuclear Power Station.

At the conclusion:of-the examination, any; generic' findings that evolved as a' result of the examinations were discussed

-with.those members of your staff identified in the enclosed report..

1 As a result of.this evaluation of your-requalification program it has been i

assigned ~ an overall program rating of satisfactory in accordance.with the

. criteria'of NUREG-1021, ES 601.. For those individuals with. unsatisfactory results, the facility should take corrective action as required by its approved requalification program.

We are requesting that you submit to'this office within thirty days of the date o_f this report a-response to the issue-of-how you train-and evaluate-operators on " uncontrolled depressurization of,all steam generators" so that future examinations may be graded consistent 1y'between NRC and facility

..V evaluators.

In; accordance with 10 CFR 2.790: of the Connission's :regu1'ations, a copy of -

f 1this. letter and the enclosures willibe placed in the NRC Public' Document Room.

'Should you have any questions concerning this examinations, please contact us.

3 a.w.

f*

Sincerely, ku :

g OR!GINAL SIGNED BY GEOFFREY C. MIE!!T

  1. .o -

.Og

> jo Geoffrey-C. Wright, Chief Operations Branch

. w

,z

+o 48

Enclosures:

> me 1 '.

Examination Report E

No. 50-454/0L-90-01 88 2..

Examinations and M> :

~ Answer Keys (SR0/R0)

See Attached Distribution R111-Rill RIII R 11 onogg

,a 1-------See Following Page ---------- --

/

a L amon/cg

.Burdick Farber Wright fpj>,

D

- 7/3 /90:

7/ /90-7/ /90 7/,2/90 fr.o v m

py u

,s J.(f,g/

  • Enj t

j.7-1 ll.g', Y 'Y

.s y jf ys [.

X*

W :y n

g ie, -

M L

JUL - 21333 I'-

. Docket No.-.50-454' r..f Docket No'. 50-455.

~q iCommonwealth Edison' Company

?g '

>; ATTN:L Mr. Corde11' Reed

<7

- Senior.Vice President Post'.0ffice. Box 767o f

1 Chicago,flL+60690f

Gentlemen:

k

SUBJECT:

REQUALIFICATION EXAMINATION REPORT E

.=.

l

'During' the weekscof May 28'and' June 4, ~1990, the' NRC administered.

L requalification ' examinations to employeesi of your organization who' operate '

ryour Byron' Nuclear Power Station.1 At the conclusion of the. examination, any x

generic findings.that evolved as a result of the examinations were: discussed-

-with tho'se members of:your staff identified in the enclosed report.

+...

d

'; As a result ofithis evaluation -of-your requalificatio'n program.it has-been tassigned an ov'erall-program rat.ing of satisfactory in accordance withithe criteria of NUREG-1021, ES 601, iFor. those individuals with< unsatisfactory.

f j ;results,t the facility should'take.: corrective action as required by its e4 tapproved requalification program.

tWe-are-requesting tha.t you submit toithis office.within th.irty days of the.

y

'dateLof this, report a: response'to the issue of theJdefinition of "uncontrolledi 9

idepressurizationnof_'all.steamgenerators",'asLidentified-inparagraph--2.b(3)'

d g;

-cofnenclosureile e v, m

LInLaccordance:with 10 CFR 2.790 of-the Commission's; regulations, a copy of:

tthO letter andithe enclosures will-be"placed in the:NRC Public Document Room, p

9

(

Should 'you have-any questions concerning'this examinations, please? contactius, s

c Sincerely, w

W 4

j

+

Geoffrey C. Wright, Chief 4

Operations Branch j

'1

Enclosures:

l

1. ' Examination Report

. No. 50-454/0L-90-01 e m

'2.

Examinations and..

i Answer Keys (SR0/R0).

-See Attached Distribution-1 L

iRIll R1 RI RIII

~'w~

cDamon/cg.

urdick er Wright l

7,

.97/J./90' 7/R/90 7/g/90

,7 / /90 s

w 3

N' l,

9;

l r :a

+

...g

%.~ '.-*:-

'1 Commonwealth' Edison Company 2

JUL - 2 B}3 Distribution cc w/ enclosures:

T. J.- Mainen,: Vice President, PWR Operations le

.. Kovach, Nuclear:

iT

.'; Licensing. Manager-R.-Pleniewicz[' Station' Manager DCD/DCB(RIDS i

LLicensing Fee. Management Branch Resident = Inspector,- Rlll: Byron Resident Inspector,~Rlll; Braidwood

. D. W. ; Cassel.J Jr., Esq.

Richard Hubbard-

.J. W. McCaffrey, Chief, Public Utilities Division

! Diane Chavez, DAARE/ SAFE

  • P. Shemanski,<NRR' LPM H. S.-Taylor, Quality: Assurance-

. Division-Robert Newmann', Office of-Public Counsel,-State of Illinois Center A. J. Chernick,- Plant Training Manager P.t Shemanski, Project Manager, NRR 4R.EGrue, Contract; Exam Supervisor l

t 4

5 4

i I

/