Responds to Item 3 of IE Bulletin 82-02, Degradation of Threaded Fasteners in RCPB of PWR Plants. Info Provided Re Valve Body to Bonnet Leakage & Corrective Actions Taken
ML20055B974
Person / Time
Site: Maine Yankee
Issue date: 07/30/1982
From: Randazza J, Randuzza J
Maine Yankee
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
REF-SSINS-6820 IEB-82-02, IEB-82-2, MN-82-150, NUDOCS 8208100005
Download: ML20055B974 (3)


Text

. _

RIAIR RHEE Aleml0POLVER00mPAlWe

,uaug,afsl,,?,lg%

k@

H (207) 623-3521 me July 30, 1982 MN-82 150 thited States t4Jclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue Kirg of Prussia, Pennsylvania 19406 Attention: Mr. Ronald C. Haynes, Regional Administrator

References:

(a) License No. OPR-36 (Docket tb. 50-309)

(b) USNRC Letter to MYAPCo, dated June 2,1982, I.E. Bulletin No. 82-02 (c) MYAPCo Letter to USNRC, dated March 24, 1982, Reportable Occurrence 82-005

Subject:

Response to I.E. Balletin No. 82-02

Dear Sir:

Action Item 3 of your letter, Reference (b), requested information for certain closures and connections in the Reactor Coolant Pressure Boundary.

The following information is provided, as directed by Action Item 5 of your letter, Reference (b).

QUESTION 3a:

Identify those bolted closures of the RCPB that have experienced leakage, particularly those locations where leakage occurred during the most recent plant operating cycle. Describe the inspections made and corrective measures taken to eliminate the problem.

If the leakage was attributed to gasket failure or its desig1, so indicate.

i 8208100005 820730

  • IMg PDR ADOCK 05000309 O

PDR

.w

M AINE YANS(EE ATOMIC POWER COMPANY united States buclear Regulatory Commission July 30, 1982 Attention:

Mr. Ronald C. Haynes, Regional Administrator Page two RESPONSE: Valve Ebdy to Bonnet Leakage 05/05/75 - LSI-12 and 32 (ANSI Class 1500 lb 10 in. Swing Check Valves *);

changed cover gaskets because of leakage.

03/10/82 - SlA-N-ll ( ASA 1500 lb 14 in. Motor Operated Gate Valve *); found evidence of leakage, tightened gasket bolting, no further leaks.

03/27/82 - LSI-22 ( ANSI Class 1500 lb 10 in. Swing meck Valve *);

tightened gasket bolting, no further leaks.

Steam Generator Manway Leakage Steam Generator No. 1:

03/07/80 - Evidence of leakage noted when shutdown; replaced gasket.

Steam Generator No. 2:

10/02/74 - Leaked during hydro (following opening); replaced gasket.

05/02/77 - Leaked during hydro (following opening); replaced gasket.

07/07/81 - Leaked during ISI Pressure Leak Test (following opening);

replaced gasket.

10/25/81 - 3/8/82 - Slight leakage noted. Leakage cu? to improper design of seal plate preventing adequate gasket compression. Seal plates modified to correct problem.

Reactor Vessel Flange March 1982 - Leakage past both 0-ring seals.

Seals failed due to fouled seating surface.

Surface cleaned and new seals installed.

QJESTION 3b:

Identify those closures and connections, if any, where fastener lubricants and injection sealant materials have been or are being used and report on plant experience with their application particularly any instances of SCC of fasteners.

Include types and composition of materials used.

RESPONSE: Fastener Lubricants and Injection Sealant Materials Maintenance practices require the use of approved lubricants when reassembling bolted closures.

As currently specified by procedure, Fels Pro N-5000 is the approved bolting lubricant (Super Moly No. 40240 was used for the Reactor Vessel Closure Studs, however, its use has been discontinued).

MAINE YANKEE ATOMIC POWER COMPANY Lhited States Wclear Regulatory Commission July 30, 1982 Attention:

Mr. Ronald C. mynes, Regional Administrator Page three RESP 0r6E TD QJESTION 3b CONT'D Furmanite Wclear F-700-N was utilized on tb. 2 Steam Generator manway. A breakdown of the constituents will be submitted within 14 days, provided that that information is not considered proprietary.

Reference (c) and subsequent correspondence provide further information on the Steam Generator Manway problem.

Further information required by Reference (b) will be provided as specified by Action Item 4.

We trust that this information is satisfactory.

If you have any further questions, please feel free to contact us.

Very truly yours, MAINE YANKEE ATOMIC POWER COMPANY John B. Randazza Vice President 33R:pjp STATE OF MAINE

)

)ss COUNTY OF KENNEBEC)

Then personally appeared before me, John B. Randazza, who, being duly sworn, did state that he is the Vice President of mine Yankee Atomic Power Company, that he is duly authorized to execute and file the foregoing request in the name and on the behalf of mine Yankee Atomic Power Company, and that the statements therein are true to the best of his knowledge and belief.

//