$SMU=

SACRAMENTO MUNICIPAL UTILITY DISTRICT O 6201 S Street, Box 15830, Sacramento, California 95813; (916) 452-3211 July 2, 1982 DIRECTOR OF NUCLEAR REACTOR REGULATION ATTENTION JOHN F STOLZ CHIEF OPERATING REACTORS BRANCH 4 U S NUCLEAR REGULATORY C0t41ISSION WASHINGTON DC 20555 DOCKET 50-312 RANCHO SEC0 NUCLEAR GENERATION STATION UNIT 1 REQUEST FOR EXEMPTION, 10CFR50.44(c)(3)(iii), NUREG 0737 ITEM II.E.1 j

The Sacramento Municipal Utility District has submitted information concerning the installation of high point vents at Rancho Seco Unit 1 in letters dated December 15,1980, July 1,1981, and March 4,1982. The installation of high point vents became a requirement in the subject rule which states that high point vents shall be provided where required to maintain adequate core cooling considering the accumulation of non-condensable gasses. The position paper submitted with our July 1,1981 letter demonstrates that a reactor vessel head vent is not necessary for removal of non-condensable gasses in order to establish natural circulation for long term cooling following a small break loss of coolant accident.in a Babcock & Wilsox designed reactor coolant system. The District has committed to the installation of hot leg high point and pressurizer vents, however, hereby requests an exemption from the subject rule for the installation of a reactor vessel head vent. This request is considered to be a Class III request and a check for $4,000 is enclosed.

.tyO $

Jo in. Mattimoe

/

Astistant General Manager gi and Chief Engineer w c, 4

Enclosure q00 8207130137 820702 PDR ADOCK 05000312 P

PDR Ah ELECTRIC SYSTEM SERVING MORE THAN 600.000 N THf HfART OF CAtif09P,A

.