ForhNRC-618 U.S. NUCLEAR REGULATORY COMMISSION t
CERTIFICATE OF COMPLlANCE 10 C R 71 For Rzd;oactivs MItykts Pickiges i
f.
1.(a) Certificate Number 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) 9151 0
USA /9151/A I
1.(e) Tot $
- o. Pages P 'es No.
iN
- 2. PRE AMBLE t
2.(a)
This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of i
Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
f 2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of I
Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or application:
Hittman Nuclear & Development Hittman Nuclear & Development Corporation, application i
Corporation dated April 5,1982, as supplemented.
0190 Red Branch Road i
Columbia, MD 21045 3.(c)
Docket No.
- 4. CONDITIONS i
This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents, Model Number, Fissile Class. Other Conditions, and
References:
(a)
Packaging 1
(1) Model No.: HN-100 Series 3 (2) Description A steel encased, lead shielded cask for low specific activity material.
The cask is a rignt circular cylinder 81-1/2 inches high by 81-3/4 inches in diameter. The cask cavity is 73-3/8 inches high by 75-1/2 inches in diameter. The cask side wall consists of a 3/8-inch thick inner steel shell, a 1-7/8-inch lead shell, and a 7/8-inch thick outer steel shell. The base is comprised of two, 2-inch thick steel plates welded together to form a 4-inch thick base which is integrally welded to the inner and outer steel shells of the side wall.
A steel flange is welded to the inner and outer steel shells of the side wall at the top. The lid is comprised of two, 2-inch thick steel plates, which are stepped and welded together to mate with the steel flange. The cask closure is sealed by a Neoprene gasket located between the lid and steel flange, positive closure of the lid is accomplished by eight (8), 1-3/4-inch rachet binders. The lid contains a centrally located shield plug comprised of two, 2-inch thick steel plates and one,1-inch thick steel plate stepped and welded. The shield plug is sealed by a Neoprene gasket, and eight, 3/4-inch studs and nuts are used to provide positive closure. The Model No. HN-100 Series 3 is constructed of A-516, Grade 70, carbon steel with a minimum yield strength of 49,000 psi.
8207080015 820622 PDR ADOCK 07109151 C
e b
Page 2 - Certificate No. 9151 - Revision No. 0 - Docket No. 71-9151 (2) Description (continued)
Tie-down is accomplished by four tie-down lugs welded to the cask body. There are four cask lifting lugs, three lid lifting lugs, and one shield plug lifting lug. The package gross weight is approximately 53,005 pounds.
(3) Drawings The packaging is fabricated in accordance with Hittman Nuclear &
Development Corp. Drawing Nos.: C001-5-9138, Rev. 6; C001-5-9139, Rev. 4; C001-5-9140, Rev. 4;.C001-5-9141, Rev. 2; C001-5-9142, Rev.1; C001-5-9143, Rev. 5; and C001-5-9144, Rev. 3.
(b)
Contents (1)
Type and form of material Greater than Type A quantities of nonfissile radioactive material as process solids, either dewatered, solid or solidified, meeting the requirements for low specific activity radioactive material (10 CFR 571.4(g)), sealed in secondary containers.
(2) Maximum quantity of material per package Not to exceed a decay heat generation of 5 watts, with the weight of the contents, secondary containers, and shoring not exceeding 19,205 pounds.
6.
Shoring must be placed between secondary containers and the cask cavity to l
prevent movement during normal conditions of transport.
7.
The lid, shield plug, and cask lifting lugs must be covered in transit to preclude their use as tie-down devices.
8.
In addition to the requirements of Subpart D of 10 CFR Part 71:
(i)
Prior to each shipment, the packaging lid seals must be inspected. The seals must be replaced with new seals if inspection shows any defects or every twelve (12) months, whichever occurs first.
(ii) Each package must meet the Acceptance Tests and Maintenance Program of Section 7.0 and Appendix E of the application.
9.
The package authorized by this certificate must be transported on a motor vehicle, railroad car, aircraft, inland watercraft, or hold deck of a seagoing vessel assigned for the sole use of the licensee.
- 10. The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
i 11.
Expiration date: June 30,1987.
I
/
l 2
Page 3 - Certificate No. 9151 - Revision No. 0 - Docket No. 71-9151 REFERENCES Hittman Nuclear & Development Corporation application dated April 5,1982.
Supplements dated: April 22 and June 17, 1982.
FOR THE U.S. NUCLEAR REGULATORY C0!EISSION ff !
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety JUN 2 21982 Date:
.