ML20054L373

From kanterella
Jump to navigation Jump to search
Interim Part 21 Rept Re Atmospheric Dump Valves Failure to Close on Loss of Air Supply.Bechtel Concluding Condition Reportable Per Part 21 Encl
ML20054L373
Person / Time
Site: San Onofre 
Issue date: 06/28/1982
From: Miller H
CONTROL COMPONENTS, INTERNATIONAL (SUBS. OF BABCOCK
To: Jay Collins
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML20054L374 List:
References
REF-PT21-82-638-000 PT21-82-638, PT21-82-638-000, NUDOCS 8207070475
Download: ML20054L373 (1)


Text

AnIMIvalveco 2567 S E. Main Str Te>ephon (714)9796600 e

, ahforn Telex 68-51 June 28, 1982 lf bl#

k!!$ f Mr. J.T. Collins OfficeRegional Administrat i

Inspectionor, Region IV 2W,.l of U.S. Nuclear Regulat and Enforcement 611 Arlington, TexasRyan Plaza Driveory Commission f

, Suite 1000 l

76012

Subject:

_J Atmospheric Dump V l Close a

on Losa of Air Supplyves Failure to

References:

Letter R.L. Patterso to Mr. J.T. Collins

, NRC, June 4,n, Bechtel Power

Dear Mr. Collins:

1982 a ion Attached Per the of a 10CFR21 reportable iattached reference you 21.21 (b) (3) VI.

were Bechtel wasadvised by Bechtel Po tem.

to We had previously re i other valves supplied and found no the problem forunable to p v ewed Sincerely, additional reportable itapplicability per ems.

/

Herbert L. Miller Vice President Control Components I nc.

dk cc:

N. Beaumont R.E. Topping N

Yp 8207070475 820628 PDR ADOCK 05000362 R

pne

. - -.., - -..,