ML20054L211

From kanterella
Jump to navigation Jump to search
Deficiency Rept Re Pullman 20-inch Q-class Pipe w/2-inch to 4-inch Visible Indications Near Weld,Initially Reported 820520.Deficiency Determined Not Reportable Per 10CFR50.55e
ML20054L211
Person / Time
Site: Palo Verde 
Issue date: 06/21/1982
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Bishop T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
10CFR-050.55E, 10CFR-50.55E, ANPP-21235-GHD, DER-82-25, NUDOCS 8207070268
Download: ML20054L211 (2)


Text

, --.

Docket Nos. 50-528/529/530 4

-p/8 50.55(e) Report REC,.EW,,ED M'M

)

WSS MMDD!0 (DDTDMIE 3003 p.o. sox 2 ses - psotnix, AR1ZON4850)p-p, STA.

June 21, 1982' ANPP-21235-Gild /BSK J

i U. S. Nuclear Regulatory Commission Region V Creekside Oaks Office Park 1450 Maria Lane - Suite 210 Walnut Creek, California 94596-5368 Attention:

Mr. T. W. Bishop, Chief Reactor Construction Projects Branch

Subject:

Deficiency Evaluation Report 82-25 A 50.55(e) Evaluation Relating to Pullman 20" Q-Class Pipe In Unit 3 Auxiliary Building lias Visible 2"-4" Indications Near Weld File: 82-019-026 D.4.33.2

Reference:

Telephone Conversation between J. Eckhardt and G. Duckworth on May 20, 1982

Dear Sir:

The NRC was notified of the subject Deficiency Evaluation in the referenced telephone conversation, with a determination of reportability to be made within thirty (30) days (June 21, 1982).

The deficiency has subsequently been determined to be Not Reportable under the requirements of 10CFR50.55(e), therefore no written report is required.

Necessary documentation of the evaluation will be maintained in APS files.

Very truly yours, RLLC (

E. E. Van Brunt, Jr.

APS Vice President Nuclear Projects ANPP Project Director EEVBJr/ Gild:db cc: See Attached Page 2 C207070268 820621 ADOCK 05000530 8'a - /77

j U. S. Nuclear Regulatory Commission Attention:

Mr. T. W. Bishop, Chief June 21, 1982 ANPP-21235-Gild /BSK Page 2 cc:

Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.

20555 J. A. Roedel D. B. Fasnacht G. C. Andognini A. C. Rogers B. S. Kaplan W. E. Ide J. Vorces J. A. Brand A. C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R. W. Welcher R. M. Grant D. R. llawkinson L. E. Vorderbrueggen G. A. Fiorelli Lynne Bernabei, Esq.

Ilarmon & Weiss 1725 "I" Street, NW Suite 506 Washington, D. C.

20006 R. L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 87503