Text
_
jk 3 3331cnTED 031GIM L F-y I
.h[
9n
'~'
edified BT_a J L" N IFiLT::TtJCG sit:;[BR71rCLs3 (DRMM
~
3003 p.o. sox 21666 PHOENIX, ARIZONA e5036 srA.
June 4, 1982 ANPP-21131-GHD/BSK 50- 62%
U. S. Nuclear Regulatory Commission 62'l Region V 630 i
Creekside Oaks Office Park 1450 Maria Lane - Suite 210 Walnut Creek, California 94596-5368 Attention:
Mr. T. W. Bishop, Chief Reactor Construction Projects Branch
Subject:
Final Report - DER 81-10 A 50.55(e) Report Relating to Hardened Washers Not Used As Required by ASME Code File:
82-019-026 D.4.33.2
Reference:
(A) Telephone Conversation between J. Eckhardt and C. T. Lewis on May 12, 1981 (B) ANPP-18183, dated June 9,1981 (Interim Report)
(C) ANPP-19520, dated November 20, 1981 (Interim Report, Revision 1)
(D) ANPP-20228, dated Februacy 22, 1982 (Interim Report, Revision 2)
Dear Sir:
Attached, is our final written report of the deficiency referenced above, which has been determined to be Not Reportable under the requirements of 10CFR50.55(e).
Very truly ours,
- c. o cT cut run E. E. Van Brunt, Jr.
APS Vice President Nuclear Projects ANPP Project Director EEVBJr/CHD:ske Attachment cc: See Attached Page 2 8206250261 820604 "
')~
gDRADOCK 05000520 i
g_
U. S. Nuclear R gulatory Commie = ion Attention:
Mr. T. W. Bishop, Chiaf ANPP-21131-Gild /BSK June 4, 1982 Page 2 cc:
Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.
20555 J. A. Roedel D. B. Fasnacht G. C. Andognini A. C. Rogers B. S. Kaplan W. E. Ide J. Vorces J. A. Brand A. C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R. W. Welcher R. M. Grant D. R. llawkinson L. E. Vorderbrueggen G. A. Fiorelli Lynne Bernabei, Esq.
Ilarmon & Weiss 1725 "1" Street, NW Suite 506 Washington, D. C.
20006 R. L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 87503
FINAL REPORT - DER 81-10 DEFICIENCY EVALUATION 50.55(e)
ARIZONA PUBLIC SERVICE COMPANY (APS)
PVNGS UNITS 1, 2 and 3 I.
Description of Deficiency Specification 13-PM-209, Section 4.3.1.2, requires supports to be fabricated to ASME Section III, Subsection NF.
ASME Section III, Subsection NF, Paragraph 4724 requires bolts tightened by means of a calibrated torque wrench shall be installed with a hardened washer under the nut or head, whichever is the element turned in tightening.
Bechtel Supplier Quality Representative noted during surveillance inspection activities that supplier, ITT Grinnell, Warren, Ohio was installing mild carbon steel washers under the bolt heads on sizes 1, 3 and 10 mechanical shock suppressors, (Figure 306, Pivot Mount, and Figure 307, Extension Assemblies). On Sizes k and h, Figures 306 and 307, Shocks, the supplier had installed hardened brass washers.
II.
Analysis of Safety Implications This condition is evaluated as Not Reportable and no rework ire required in regard to the identified supports.
Code Interpretation NI 81-163, indicates that the use a.
of hardened brass washers is in compliance with NF-4724.
b.
Based on a successful testing program by ITT Grinnell concerning the use of mild steel washers, Code Case N-338 has been approved by the May, 1982 ASME Committee.
This Code Case is scheduled to be issued in Supplement 12 to the 1980 Code Case List.
III.
Corrective Action The Code Case number shall be indicated on the documentation for each applicabic support and this Code Case shall be included in the FSAR.
.r Ey The Amarican Society of Mcchanical Enginocro
-S-i United Engineenng Center
- 345 E 47th St., New York, N Y.10017 e 212-644 7722 e TWX-710-5815267 Attachment to DER 81-10 January 18, 1982 Bechtel Group, Inc.
P.O. Box 3965 San Francisco, CA 94119 Att:
W. H. Borter
Subject:
Section III, Division 1 NF-4724 Bolt Tension
Reference:
Your letter of Octobert 21, 1981 ASME File # NI 81-163 Gentlemen:
Our understanding of the question in your in'quiry, and our reply are as follows:
Question: Does paragraph NF-4724 of ASME Section III permit the use of a hardened brass washer under the nut or bolt head which is turned in tightening, when high strength carbon or alloy steel bolts are tightened by means of a calibrated wrench?
Reply: Yes.
Your truly, h
W John Millman Assistant Secretary (212) 644-8049 u
ASME procedures provide for reconsideration of this interpretation when or if additional information is available which the inquirer believes might affect the interpretation. Further, persons aggrieved by this interpretation may appealto the cognizant ASME committee or subcommittee. As stated in the foreword of the Code documents ASM E does not " approve "" certify "" rate," or " endorse" any item, construction, propnetary device or activity.
--e
i Cods Casa N,$.I S
T
/,
Usa of !!ild Sesol W2thcrs f r S;ction III, Divisica 1, Ccustruction
$UNhm Tor construction to ASE Section III, Division 1,pT vhat alternatives :nay be used in lieu of the hardened washers required in N7-47:47 i
SLL,,4f,,
~
It is the opini:n of the Comittee that for Section III, Division 1 se:uctics, icv carbon steel vashers may be used as an altst=ative tb, NF con-he hard-ened washers required *by NF-47 4 provided that:
1.0 it.e bolts or studs are used to cennect =aterial having a specified eini=u=
yield strength equal to or greater than 40 kai.
2.0 A test for each combination of materials, size and length of bolts or stud shall be perfor=cd to verify tha.c the vasher does not prevent the recuired A
preload frem being deQped. A / cerci::. cation c..at ene ces; nas be.en per-
- f for=ed and the results acceptable to the designer shall be attached to ene 3
gg doe =sentatica for these supports.
dad 3.0 All other applicable requirmats of Section III are met.
4.0 This Case nu=ber shall be indicated on the docu=entation for the support.
==
a l
l l
l l
t 6
l t
y-]-
'a