Food and Drug Administration Rockville MD 20857 JUN 21 1988 Mr. Louis L. Wheeler Project Manager Office of Nuclear Reactor Regulations U.S. Nuclear Regulatory Comission Washington DC 20555
Dear Mr. Wheeler:
'Ihe Bureau of Radiological Health staff have reviewed the Draft Environmental Statement (DES) related to the operation of Seabrook Station, Units 1 and 2, NURE-0895, dated May 1982.
In reviewing the DES, we note that (1) the application for a construction permit was received in March 1973, (2) the Final Environmental Statement -
Construction Phase was issued in December 1974, (3) the construction permit was not issued until July 1976, and (4) as of March 1982, the construction of Unit 1 was about 61 per cent complete. The Bureau of Radiological Health staff evaluated the health and safety impacts associated with the proposed operation of the plant and have the following comments to offer:
1.
The dose design objectives of 10 CFR 50, Appendix I, the Uranium Fuel Cycle standards of EPA's 40 CFR 190, and the applicant's proposed radio-active waste managen.ent system provide adequate assurance that radioactive nuterials in the effluents will be maintained as low as reasonably adilevable (ALARA).
It appears that the calculated doses to individuals and to populations are within current radiation protection standards.
2.
The environmental pathways in Section 5.9.3 and shown in Figure 5.2 cover all possible emission pathways that could impact on the population in the environs of the facility. The dose computational methodology and models (Appendix B and D) used in the estimation of radiation doses to individuals and to populations within 80 km. of the plant have provided the means to make reasonable estimates of the doses resulting from normal operations and accident situations at the facility. Results of the cal-culations are shown in Appendix D, Tables D.6, D.7, D.8, and D.9.
The results confirm that the calculated doses meet the design objectives.
3.
Discussions in Section 5.9.4 on the environmental impact of postu-lated accidents is considered to be an adequate assessment of the radi-ation exposure pathways depicted in Figurea 5.2.and 5.3 and the dose and health impacts of atmospheric releases. However, in Section 5.9.4.2(2),
two additional pathways are mentioned that could be significant for accident releases. These are (1) fallout onto open bodies of water of radioactivity initially carried in the air, and (2) the " China Syndrome" that creates the potential for release of radioactive materials into the hydrosphere through contact with ground water.
If possible, it would be helpful to expand the discussion in Sections 5.9.4.2(2) and 5.9.4.2(5) l on releases to ground water to quantify the environmental and health l
impacts f rom the latter pathway in sufficient detail to permit an under-standing of the consequences of such an event.
l 8206230113 820621 i
PDR ADOCK 05000443 D
Mr. Louis L. Wheeler - Page 2 We will forego comments on Section 5.9.4.3(3) relating to emergency preparedness since we realize the process of granting an operating license will include an adequate review of the emergency preparedness plan for the station by NRC and the Federal Emergency Management Agency (FEMA).
In this context, it is essential that the factors impacting on the capability to evacuate the beaches be fully understood and are factored into the station, state and local governments emergency response plans. The NRC's independent evacuation time estimation study should provide timely input to the respective plans. We have represen-tation on the RAC's whose evaluation relative to the emergency prepared-ness for the Seabrook Station will speak for this department.
4.
The radiological monitoring program, as presented in Section 5.9.3.4 and sunmarized in Table 5.6, appears to provide adequate sampling fre-quency in expected critical exposure pathways.
The analyses for specific radionuclides are considered sufficiently inclusive to (1) measure the extent of emissions from the plant and (2) verify that such emissions meet applicable radiation protection standards.
In view of some of the monitoring problems identified during the
%ree Mile Island, Unit 2, accident, we suggest reevaluation of the airborne radiciodine and particulates sampling and analysis program to determine if the instrumentation is adequate to measure releases under accident conditions.
In particular, address the problem of monitoring radiohalogens (especially radiciodines) in the presence of radionoble gases. % is could be accomplished by reference to FEMA-REP-2, a document on instrumentation systems prepared with considerable input from NRC.
5.
Section 5.10 and Appendix C contain descriptions of the environ-mental impact of the Uranium Fuel Cycle (UPC). We environmental effects presented are a reasonable assessment of the population dose canmitments and health effects associated with release of radon-222 from the UFC.
%ank you for the opportunity to review and comment on this Draf t Environnuntal Statement.
Sincerely yours, f
.ohn C. Villforth Q1 rector Bureau of Radiological Health
/