Forwards Updated Status of NUREG-0737 Items,Clarifying Util Responding to Generic Ltr 82-05.Items Include I.A.3.1,II.B.2,II.B.3,II.B.4,II.E.4.2,II.F.1,II.K.2.10, II.K.3.15,II.K.3.19,II.K.3.22,II.K.3.24 & II.K.3.27
ML20054G974
Person / Time
Site: Oyster Creek
Issue date: 06/15/1982
From: Fiedler P
GENERAL PUBLIC UTILITIES CORP.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-1.A.3.1, TASK-2.B.2, TASK-2.B.3, TASK-2.B.4, TASK-2.E.4.2, TASK-2.F.1, TASK-2.K.2.10, TASK-2.K.3.15, TASK-2.K.3.19, TASK-2.K.3.22, TASK-2.K.3.24, TASK-2.K.3.27, TASK-TM GL-82-05, GL-82-5, NUDOCS 8206220460
Download: ML20054G974 (4)


Text

~

C' GPU Nuclear

\\',

, ' ~

g gf P.O. Box 388 Forked River. New Jersey 08731 609-693-6000 Writer's Direct Dial Number:

June 15, 1982 Mr. Darrell G. Eisenhut, Director Division of Licensing Of fice of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 De=v Sire

Subject:

Oyster Creek Nuclear Generating Station l

Docke t No. 50-219 G,neric Letter 82-05 As a result of discussions between our licensing representative and the projec t manager, it was decided to update and clarify my April 20, 1982 re spons e t o Generic Le tter 82-05.

For the purpose of completeness, we have included our responses to all of the specific NUREG 0737 items in Enclosure 1 of this letter.

In addition to the specific schedule justifications provided in Enclosure 1, it should be noted that Oyster Creek was originally scheduled to begin the Cycle I

10 reload refueling outage in November 1981.

For a number of reasons, this outage is now scheduled for January 15, 1983. While this may appear as a significant delay, the actual time of operation of the plant has only been extended by a period of approximately 6 months. Also, the plant is presently operating at approximately 84% of power and uill coastdown until the refueling outage begins.

These f acts provide additional assurances that Oyster Creek will continue to operate safely until all the NUREG 0737 items can be completed.

Very truly yours, J i c/ v >A _ A, u

  • 1 Pe t e'r B. Fiedler Vice President and Director Oyster Creek PBF:JK: Ise

(

Enclosures I

W2gggeggg P

GPU Nucn m a omt of the General PuDhc Utihties System 1

_J

a s

ENCLOSURE 1 1.

I.A.3.1 Simulator Exams This item was implemented in accordance with the NUREC 0737 schedule and Oyster Creek Operator candidates are administered their simulator exams as part of the Operator Licensing Examination process.

2.

II.B.2 Plant Shielding This item is complete with the exception of tie-in for the Standby Gas Treatment System (SBGTS)

The SBGIS tie-in will be made during the upcoming refueling outage.

This is justified for the following reasons:

This tie-in is to an essential system which can only be e

accomplished during a refueling outage, e

There are two (2) trains of SBGT in the event one filter train became saturated the redundant train would be available, o

An additional shutdown would cause economic hardship for the GPU Corporation and its customers.

3.

II. B.3 Post Accident Sampling The final modifications for taking a Reactor Coolant Sample will be installed during the Cycle 11 refueling outage.

The justification for this schedule is provided in our December 24, 1981 submittal and Enclosure 3 thereto.

4.

II. B.4 Training for Mitigating Core Damage Completed January 1982 5.

II.E.4.2 Containment Isolation Dependability a.

Pa rt 5 Complete in accordance with NUREG 0737 schedule.

b.

Part 7 GPUN has requested deferral of this item pending NRC resolution of our position that the unique circumstance of Oyster Creek does not warrant this modification.

Justification is provided in the following letters:

August 27, 1982; December 24, 1981; Fe brua ry 10, 1981; and February 25, 1982

1

-2_

6.

II.F.1 Accident Monitoring (1) Noble Gas Monitors To be completed during the Cycle 10 refueling outage A pit at shutdown is required to accomplish this which would e

cause severe economic hardship for GPUN and its customers.

This schedule is justified by:

There are existing monitors; however, the instrument range is o

not as specified - NUREG 0737 (2) Effluent Monitoring of lodine To be completed during the Cycle 10 refueling outage A plant shutdown is required to accomplish this which would e

cause severe economic hardship for GPUN and its customers.

(3) Containment High Range Monitor To be completed during the Cycle 11 refueling outage.

This is justified because of the following:

There are numerous other methods for detecting a major e

accident within containment such as high drywell pressure, low low reactor water level, torus water level, neutron monitoring, etc.

Theret' ore, this instrument only provides an additional indication of major core degradation.

(4) Continuous indication of Containment Pressure To be completed during the Cycle 10 refueling outage A plant shutdown is required to accomplish this which would e

cause severe economic hardship for CPUN and its customers.

There are existing monitors with control room indications; e

however, the range is not that specified in NUREG 0737.

t e (5) Continuous Indication of. Containment Water Level To be completed during the Cycle 10 refueling outage A plant shutdown is required to accomplish this which would e

cause severe economic hardship for GPUN and-its customers.

e There are existing monitors with control room indications; however, the range is not that specified in NUREG 0737.

(6)

Continuous Indication of H2 in Containment To be completed during the Cycle 10 refueling outage.

A plant shutdown is required to accomplish this which would e

cause severe economic hardship for GPUN and its customers.

7.

II K.2.10 Safety Grade Training Not Applicable 8.

II.K.3.15 Isolation of HPCI and RCIC Modification Not Applicable 9.

II.K.3.19 Interlock of Recirc Pwsp Final modifications will be completed during the Cycle 11 refueling outage.

Justification for this schedule is provided in our December 24, 1981 submittal and Enclosure 3 thereto.

10.

II.K.3. 2 2 RCIC Suction Not Applicable f

11.

II.K.3.24 Space Cooling for HPCI/RCIC i

Not Applicable 12.

II.K.3.27 Common Reference Level i'

Complete as stated in the following letters to you dated:

June 23, 1980, September 26, 1980, February 10, 1981, as clarified j

in our May 7,1982 correspondence.

f