YANKEE ATOMIC ELECTRIC COMPANY 2.C.2.1
- y 1671 Worcester Road, Framingham, Massachusetts 01701 FYR 82-52
~~
May 28, 1982 United States Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, PA 19406 Attention:
Mr. Ronald C. Haynes, Director Region I Of fice of Inspection and Enforcement
References:
(a)
License No. DPR-3 (Docket No. 50-29)
(b)
USNFC Letter to YAEC, dated April 26, 1982
Subject:
Emergency Public Notification System
Dear Sir:
This letter is to report on the status of our augmentation of the Emergency Public Notification System within the Yankee Emergency Planning Zone.
As we have indicated verbally to your office on a periodic basis since February 1,1982, we had identified the need for certain additions to the system as a result of system testing and evaluation following our initial installation efforts. The additions we identified and their status as of this date are outlined below.
Sirens for North Adams Following the initial installation and sound-level testing of two sirens within North Adams, MA, the need for two additional sirens was identified.
Over the past three months, the sites for these additional sirens were prepared, the sirens were delivered from the manufacturer and installed; and, on May 20,1982, they were sound-level tested.
The results of the sound-level tests show the public notification system work for North Adams, MA la now complete.
Modification of Colrain Siren An existing siren in the Town of Colrain, MA was modified.
The siren was successfully sound-level tested on May 20, 1982. This completes the siren I
portion of the public notification system work for Colrain.
Additional Weather Alert Radios Following the initial distribution, two towns identified the need for additional NOAA weather alert radios. The Town of Colrain, MA requested approximately 200 additional radios and the Town of Wilmington, VT requested 8206220382 8206iO PDR ADOCK 05000029 PDR
8 D
y United, States Nuclesr R:gulatory Commission auna 1, 1982 Attention:
'Mr. Ronald C. Haynes Pzga 2 approximately 36 additional radios. Since our original supply had all been distributed, we had to place aa order with the manufacturer for an additional supply. This order was delivered to us on May 21, 1982. On May 26, 1982, we delivered the additional radios to officials of Colrain and Wilmington.
This completes our ef forts on the public notification system for these towns.
System Summary With the above-described siren installations and testing and additional weather radio distributions, the public notification system for the Yankee EPZ is now complete. The completed system consists of a combination of notification methods, as shown in the following community listing.
Community Public Notification System Method (s)
Massachusetts:
Buckland One (1) Mobile Public Address System Charlemont one (1) Siren, One (1) Mobile Public Address System and 300 Weather Radios (including six outside antennas)
Clarksburg Three (3) Sirens and 50 Weather Radios Colrain Two (2) Sirens and 392 Weather Radios Florida Three Hundred Nine (309) Weather Radios (including seven outside antennas)
Ibwley One Hundred (100) Weather Radios Heath Three Hundred Fifty-Five (355) Weather Radios Monroe Ninety (90) Weather Radios North Adams Four (4) Sirens Rowe One Hundred Seventy-Five (175) Weather Radios Savoy Sixty-Five (65) Weather Radios (including eleven outside antennas)
Ve rmont :
Readsboro Five Hundred Thirty (530) Weather Radios Stamford Two Hundred Seventy-Five (275) Weather Radios and a Direct Dial Telephone Whitingham Five Hundred Thirty-Five (535) Weather Radios Wilmington One Hundred One (101) Weather Radios We trust this information is complete and you sill find it satisfactory.
If you have any further questions, however, please do not hesitate to contact us.
Very truly yours,
,Y EE ATOMIC LECTRIC COMPANY K,.
4
.).
A. Kay Senior Engineer Licensing JAK: dad
_.