2 Dock:t Nos. 50-529/529/5 8

~ 50.55(e) Report RECEWED T

l' 7 JL"WWMA IFUMRC 9121,7YII@EW@@TERKLSTE9 3003 3y, po,,ox,3,,,

,gogy,x,,n,,ogy,3,3, I'

May 26, 1982 ANPP-21041-CHD/BSK

(

U. S. Nuclear Regulatory Commission Region V Creekside Oaks Office Park 1450 Maria Lane - Suite 210 Walnut Creek, California 94596-5368 Attention:

Mr. T. W. Bishop, Chief Reactor Construction Projects Branch

Subject:

Time Extension for Report - DER 82-4 A 50.55(e) Potentially Reportable Deficiency Relating to Design Specification Drawings for Instrument Clamps Do Not Show Locknuts As Required By ASME III Code File: 82-019-026 D.4.33.2

Reference:

(A) Telephone Conversation between J. Berdoin and J. Cook on March 3, 1982 (B) ANPP-20607, dated April 1, 1902 (Interim Report)

Dear Sir:

The NRC was notified of a potentially reportable deficiency in Reference (A) and an Interim Report was transmitted by Reference (B). At that time, it was estimated that a Final Report would be available by May 26, 1982.

Due to the extensive investigation and evaluation required, it is now expected that this information will be finalized by August 26, 1982 when a complete report will be submitted.

There is no new information or change to the Interim Report at this time.

Very truly yours M

h tLL E. E. Van Brunt, Jr.

APS Vice President Nuclear Projects ANPP Project Director EVBJr/GHD:skc I ['l' i cc: See Attached Page 2 8206150184 820526 PDR ADOCK 05000528

{j -ph

]

U PDR

I U. S..Nucisar Ragu.ory Conunission Attantion:

Mr. T. W. Bishop, Chief ANPP-21041-GHD/ESK May 26, 1982 Page 2 cc:

Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Eegulatory Commission Washington, D. C.

20555 J. A. P.oedel D. B. Fasnacht-G. C.-Andognini A. C. Rogers B. S. Kaplan W. E. Ide J. Vorees J. A. Brand A. C. Gehr

'W. J. Stubblefield W. G. Bingham R. L. Patterson-R. W. Welcher R. M. Grant D. R. Hawkinson L. E. Vorderbrueggen G. A. Fiorelli Lynne Bernabei, Esq.

Harmon & Weiss 1725 "1" Street, NW Suite 506 Washington, D. C.

20006 R. L. Greenfield Assistant Attorney General Bataan Memorial BuildirA Santa Fe, New Mexico 87503