Forwards Response to IE Bulletin 80-13 Re Insp of Core Spray Spargers.Resolution of Camera Sys Used for Visual Insp Demonstrated by Underwater Viewing of Metallurgical Sample. No Abnormalities Found
ML20054D929
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 01/04/1982
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: Orreilly J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-SSINS-6820 IEB-80-13, NUDOCS 8204230514
Download: ML20054D929 (2)


Text

  • * "

TENNESSEE VALLEY AUTHORITY USNRO R= ni3N -

,. CHATTANDDDAcTff4/4ESSEE 37401

' 400 Chestnut'Str'det 'Itser II 32 J AN 6 All: N January 4, 1982

~

S Mr. James P. O'Reilly, Director Office of Inspection and Enforcement t

APR 22198k To U.S. Nuclear Regulatory Comission p ge st uea m m e s s Region II - Suite 3100 g

    • y** #

101 Marietta Street

//

Atlanta, Georgia 30303 q,

Dear Mr. O'Reilly:

OFFICE OF INSPECTION AND EtEORCEMENT BULIEPIN 80 RII:JPO 50-259, -260,

-296 - BRG4NS FERRY NUCLEAR PLANP In response to the subject bulletin we have performed an inspection of the core spray spargers on Browns Ferry Nuclear Plant unit 3.

Enclosed are the results of the inspection.

If you have any questions, please call Jim Dmer

(

at FTS 858-2725, 1

To the best of my knowledge, I declare the statements contained herein are ccrnplete and true.

Very truly yours, TENNESSEE VALLEY AUIHORITY

(

?.

L~~M. Mills, Ma' nager Nuclear Regulation and Safety Enclosure l

cc: Office of Inspection and Enforcement (Enclosure)

Division of Reactor Operations Inspection U.S. Nuclear Regulatory Cmmission Washington, DC 20555 8204280 5\\4 T Enst g

o-,1mem.

- (

9..

DCIMURE IE Bulletin 80-13 Browns Ferry Nuclear Plant A visual inspection of the core spray sparger and piping internal to the reactor vessel was performed on Browns Ferry unit 3 during a four-hour period on December 2, 1981. Resolution of the camera system used for visual inspection was denonstrated by underwater viewing of a metallurgical sample with one-mil cracks. No abnormalities were found. Total exposure to the five individuals performing the inspectior. was 50 millirem.