e 6
a, Document Control 50-382 LPDR l
APR 141982 PDR T4 SIC TERA LB#3 Files Docket No.: 50-382 JLee
[ p i A,,
SBlack OELD
\\-
Mr. L. V. Maurin 1&E x
Vice President - Nuclear Operations ACRS (1,k
- Q y7 g
Louisiana Power and Light Company L
,U 61982 w 142 Delaronde Street
,[$$[$qu N
liew Orleans, Louisiana 70174 5
nenm 7;d
Dear Mr. Maurin:
//
through May 13,s r This letter is to confirm the dates Iby 10, 1982 4
for a visit by the HRC staff and its consultants to your control r The objective of this visit is to prepare a preliminary evaluation of the control room with regard to the following:
The adequacy of information presented to the operator to reflect 1.
plant status for normal operation, anticipated operational occurrences, and accident conditions; 2.
The groupings of displays and the layout of panels; Improvements in the safety monitoring and human factors enhancement 3.
of controls and control displays; The comunication from the control room to points outside the control 4.
room, such as the on-site Technical Support Center.
(This comunication link must also be coordinated with new requirements for transmission of plant systems data to NRC);
The use of direct rather than derived signals for the presentation 5.
of process and safety information to the operator; The operability of the plant from the control room with multiple 6.
failures of non-safety-grade and non-seismic and control room systems; The categorization of alarms, with unique definition of safety alarms.
7.
To assist the staff in its evaluation, your cooperation is requested in the following ways:
1.
Admittance of several people to the contial room as needed for the duration of the visit; 2.
Three qualified control room operators to assist the staff for the duration of the visit; Permission to use photogpaphic equipment in the control room; 3.
4.
Access to copies of syster.i operating procec ures used in control room
)
or,,a y
_g"
" Operations;" -
8204220221 B20414
+.
"' PDR ADOCK 05000382 au
" S m = -3 =
OFFICI AL RECOFiD COPY Nwc ronu atu no coinncu o24o
~m e
,,.,y p
p 7
a 3
tg
- Apg 141982
/-
5.
Availability of consultants who prepared the preliminary design assessment; 6.
An arrangement for security clearance for the team equipment: 35 m cameras and tripod
- briefcases
- light measurement equiriment
- humidity / temperature measurement equipment
- sound measurement equipment 7.
Access to a copying machine; 8.
A briefing and debriefing' with plant management capable of committing to control room changes.
A minimum of two weeks prior to our visit, we request that you send us the following:
1.
A list of abbreviations used on Panels / Systems / Subsystems; 2.
A description of the control room color code standard; and 3.
The name(s) and phone number (s) of the contact (s) at the control room.
We expect to be at the Waterford security gate at about 9:00 a.m. on Monday, May 10, 1982.
Please feel free to telephone Ms. Ann Ramey-Smith at (301) 492-8983, or
~
Mr. Ray Ramirez at (301) 492-8106, if additional infomation is needed relating to the control room' visit. Your cooperation in this important matter is appreciated.
Sincerely, original signed by gebeg_L. Tedesoe Robert L. Todesco, Assistant Director for Licensing Division of Licensing cc: See r. ext page.
.n.:no.@..ntg4.....gAot.t...
""*>.SCBlack.db..F.JMi ' gl.4.......RLIa s.co...
C*>.. 4.('/1../. 8. 2......
.... 4. M... /.8. 2......
... 4. /.. /.'3.8. 2.....
NCC FORM 318 IIO/80lNHCM 0240 OFFICIAL RECOFiD COPY
- "'**-33'*]
m
< o Mr. L. Y. Maurin WATERFORD Vice President - Nuclear Operations Louisiana Power & Light Company 142 Delaronde Street New Orleans, Louisiana 70174 W. Malcolm Stevenson, Esq.
Monroe & Lemann 1424 Whitney Building New Orleans, Louisiana 70130 Mr. E. Blake Shaw, Pittman, Potts and Trowbridge 1800 M Street, N. W.
Washington, D.C.
20036 Mr. D. L. Aswell Vice President, Power Production Louisiana Power & Light Company 142 Delaronde Street New Orleans, Louisiana 70174 Mr. F. J. Drummond Project Manager - Nuclear Louisiana Power & Light Company 142 Delaronde Street New Orleans, Louisiana 70174 Mr. D. B. Lester Production Engineer Louisiana P6wer & Light Company 142 Delaronde Street New Orleans, Louisiana 70174 Lyman L. Jones, Jr., Esq.
Gillespie & Jones P. O. Box 9216 Metairie, Louisiana 70005 Luke Fontana, Esq.
824 Esplanade Ave.
New Orleans, Louisiana 70116 Stephen M. Irving, Esq.
535 North 6th Street Baton Rouge, Louisiana 70802 Resident inspector /Waterford NPS P. O. Box 822 Killona, Louisiana 70066 Dr. D. C. Gibbs Middle South Services, Inc.
P. O. Box 61000 New.0rleans, Louisiana 70161
-m-