D Southern California Edison CompiHygpg WE S AN ONOPRE NUCLE AR GENER ATING 5, AYlON

/

R.o...,,.

IQ:,

.AN e a u,Nr. eau,vo.N.A n.n H. B. R AY April 5,1982 nav'ON =aNaana Q

9 o

44 U. SI Nuclear Regulatory Commission d

p C Office of Inspection and Enforcement j/

,)

,~

,,. 3 Region V

, h 4,

L o

{-[.

'/"'

b. f 1450 Maria 1.ane, Suite 210 Walnut Creek, California 94596-5368

(

gg

/

s e !

h(pp;e Attention:

Mr. R. H. Engelken, Regional Administrator Sub.iect:

Docket No. 50-206 San Onofre - Unit 1

Dear Mr. Engelken:

This letter describes a reportable occurrence involving two integrally welded pipe supports in the feedwater system at San Onofre Unit 1.

This report is made in accordance with section 6.9.2a of Appendix A to the Provisional Operating License DPR-13.

During the performance of a scheduled Inservice Inspection, a visual examination revealed failed attachment welds on feedwater system pipe support

  1. 1-KBG-391-1 and #1-KBG-393-1.

These supports are located on the feedwater inlet lines to steam generators E1C and EIA respectively.

Our investigation of this event is still in progress. A complete report of this matter together with a Licensee Event Report will be forwarded within 14 days.

Hf#,7 @g cc:

U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement

b. S. Nuclear Regulatory Commission TNA Office of Management Information and Program Centrol

.r/

Institute of Nuclear Power and Ocarations (INPO)

//o L. F Miller - USNRC Resirient Inspector - Unit 1 8204160600 820405 PDR ADOCK 05000206 g