I S

PROPOSED TECl!NICAL SPECIFICATIONS SEQUOYAll IJUCLEAR PLANT UNIT 1 l

P P

B206070667 820527

' PDR ADOCK 05000327 P

PDR

~

s e

C. en r.il Km.ste r Huvic.ir S.if e t v keview St:aff tlanager of r wer o

i Nuc le.er S.if ety L view Res.ord J

Deputy Hepager of Power (Energy Supply)

I Director of Nuclear Power Assistant Director of 4

  • t.m t e w 6we h

i I

Plan-ager of Manager of Nuclear Technical Product inn Support Assistant HJnager of Nuclear Sector Engineer Preoperatfonal Test Staff Asa!stant Manager of Technical Support Browns Ferry

]

Nuclear Plant quality Assurance and Compliance i

Branch Sequoyah Nuclear Plant

  • Emergency Preparedness and Protection B ranc h k'.a t t s Bar Nuclear Plant Nuclear Training B rancia 8ellefnnte Nuclear Plant Nechanical Branch I

Field Services B ra nc h l

~

1

/

Reactor f

Engineering

- Branch

  • Responsible for fire prnrection.

1 Liectrtcal and SEQUOYAH UNIT 1 3^$"""'

'"d Controts Bracch 6-2 rieure 6.31 erf site orcanintinn for ractuty Maran.ement and Technical S prort m.

._.m

._-+_m__-

s__

~._.

m.

m _

Jk b

PLANT FACEJTv ORGANttATON-SEOUOY AH SLETRtdTENDENT m

.O O

C I DIECN h d

i NUCLEAR POWER l

'0U AlffY ASSUR ANCEI g AND COMPLtANCE O h

l. _ _ I""".CH, _,,;

P-4 d

4 uANAccm p

TECHN8C AL p.

_-3 W

g RT 0

3 FE1.D OUALfTY l OUAUTY

_______"5_"

' ASSunANCE STAFr i ASSURANCE ONSm t-___

e.cu e0LNr u,NA E.

SAFETY ENGeeELF.NG cROu,,

Sun RvcoR 0ffsite

__.OuAuT, ASSURANCE


l------

1 SECTON Onsite T

I QUAlfTY AS = ANCE r-c~ ear,,

w COOR,,,A,OR

. NUCLEAR,0.ER : i OUAun j

ASSURANCE e FIELD SERVICES Euc,, Ens L _ _ _M ^*C"_ _ _a i

i 1

l

--g ENGINEERING & OPERATIONS HEALTH & SAFETY SERVICES MAINTENANCE I

I I

1 i

ASStST ANT ASSISTANT ASSESTANT FiEu,.

PLANT PtmT omSO. or euNr I

I SERVICES -

SLPERr4TENDENT SLFERadTURNT 1 POWER SYSTEMS I SLPER9dTENDD(T I

L _ _OPERATONS__-___J 2

l r----0--I r-------

I l

l 1

M.'BLC SAFETY 8

{

l.

l e

l uEOCAL MEDCAL.

SECLftfTY

---4 p'

ENG#dEERNG CPERA TONS SERVCES uCCHANCAL

  1. sSTRUMENT ELEC TRC AL 3

SECTON SECTON L- _ _

- _J L _ _ _ _ _ _ _ _ _1 PSO

"^***

SECTON SECTON SECTON SUPERVGOR SUPERVtSOR gno SLPERVISOR

$UPERVGOR gypggygog r DNC OM OF----- 7 r - DECN OF----- 7 g

HEALTH POWER i,

g i OCCLP A TON AL.

RW pgyggg

--.~

STORES 9

}

CHEM

  • CAL WY I HC.ALTH & SAFETY j TEQf4 CAL DGRS TECHNCAL EN3RS TECHNCAL ENGRS L' - & SERVCES CPER T S I

SurtRvsca SECTON


_J MRWm FOREMEN FOPEWM j

SUPERVASOR gpg OWTSMEN CRAFTSMEN CRAFTSMEN I

r 7,,,;S0;7&- 7 TRA W g NUCLEAR POWER I ENGhEERe4Q R SHFT ENOtsEER O

SCRv1CES S FF TE ST UNIT SRo LABORER SERVICES n

St.;PERVISOR I

SUPERVtSOR i

LEGEND:

4 A SST. SMFT I

l p== -.= q 1

ENGNEE R REACTOn son

  • SArETv fc q stANY MANAGEMENT l

l Offsite

  • Responsible for ENCPdERr4Q UNIT I

ENG9(ERNG COMPLIANCE SERVCE S 5.

._ - 4 l

fire protection StPERvCOR SurTRVGOR 6

$UPERVISOR SUPCRvtSOR

(

Communication unit O*ERATOR

    • ISEG functions are e

R P rting perf rmed by PLANT Figure 6.2-2 COMPLIANCE STAFF 4

e 4

A ADMINISTRATIVE CONTROLS I

6.2.3 INGEPENDENT SAFETY ENGINEERING GROUP (ISEG)

FUNCTION

~ - -

6.2.3.1 The ISEG shall function to examine plant operating charac.teristics,-.

NRC issuances, industry advisories, Licensing Event Reports and other sources which may indicate areas for improving plant safety.

performed by the Plant Compliance Staff.

The ISEG functions are COMPOSITION 6.2.3.2 The ISEG shall be composed of at least five dedicated full-time engineers located onsite.

RESPONSIBILITIES 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of plant activities to provide independent verification

  • that these activities are performed currectly and that human errors are reduced as much as practical.

AUTHORITY 6.2.3.4 The ISEG shall.nake detailed recommendations for revised procedures, equipment modifications, or other means of improving plant safety to the Assistant Director for Maintenance and Engineering of-the Division of Nuclear Power.

6.2.4 SHIFT TECHNICAL ADVISOR (STA) 6.2.4.1 The STA shall serve in an advisory capacity to the shift supervisor on mattars pertaining to the engineering aspects of assuring safe operation of 1

the unit.

I

6. 3 UNIT STAFF QUALIFICATIONS 6.3.1 Each member of the unit staf f shall meet or exceed the minimum qualifi-cations of ANSI N18.1-1971 for comparable positions and the supplemental requirements specified in Section A and C of Enclosure 1 of the March 28, 1980 j

NRC letter to all licensees, except for the Health Physicist who shall meet or j

exceed the qualifications of Regulatory Guide 1.8, September 1975.

i r

i i

"Not responsible for sign-of f function.

SEQUOYAH - UNIT 1 6-7 y

...ma

=~

-.-v

.<+-y,

,--w-r-y ar-=r,

--y---

yw-

,,+,--,rw--,

-,---,-e.

r v-,

4 ADMINISTRATIVE CONTROLS 6.4 TRAINING 6.4.1 A retraining and replacement training program for the unit staff shall be maintained under the direction of the appropriate Assistant Plant Superintendent and shall meet or exceed the requirements and reccommendations of Section 5.5 of

- ANS1 N18.1-1971 and Appendix "A" of 10. CFR Part 55 and the supplemental requiremer.ts specified in Section A and C of Enclosure 1 of the March 28,1980 NRC letter to all licensees, and shall include familiarization with relevant' industry operational experience identified by the ISEC.

6.5 REVIEW AND AUDIT 6.5.0 The Manager of Power is responsible for the safe operation of all TVA power plants. The functional organization for Review and Audit is shown on Figure 6.2-1.

6.5.1 PLANT OPERATIONS REVIEW COMMITTEE (PORC)

FUNCTION 6.5.1.1 The PORC shall function to advise the Plant Superintendent on all matters related to nuclear safety.-

COMPOSITION 6.5.1.2 The PORC shall be composed of the:

Chairman:

Plant Superintendent Member:

Operations Supervisor Member:

Engineering Supervisor Member:

Instrument Maintenance Supervisor i

Member:

Electrical Maintenance Supervisor j

Member:

llealth Physics Supervisor Member:

Quality Assurance Staff Supervisor Member:

Mechanical Maintenance Supervisor i

i i-t l

SEQUOYAH - UNIT 1 6-7a

_..~._ _ _..,

PROPOSED TECHNICAL SPECIFICATIONS SEQUOYAH NUCLEAR PLANT UNIT 2 k

f:en. r.il Mai arer Nut iv t r Lef t t y Review $t.sff ttanager of Pawe r m

Nuclear biety keview P.arel Det.ut v H on.tr.cr of Power (Energy Supply)

I Directnr of Nuclear Power Asststant Dlrector of N..c t n e power i

l I

Han..ger of llanar.er of Nuclear Technical Productton Support Assistant Man.iger of Nucle.nr e.,e

,..s

'enior Eigineer Preoperational Test Staff Assistant Manager of Technical Support Browns rerry Nuclear Plant Quality Assurance and Compliance Branch Sequoyah Nuclear Plant

  • Emergency Preparedness acd Protection Branch Watts Bar Nuclear Plant Nuclear Training Branets Betlefonte Nuclear Plant Mechanical

~

Branch

~

Field Services B ra nc h

/

Reactor Engineering Branch

  • Respongible for fire protection.

Llectrical and

'"'"""'"5'"d SEQUOYAll UNIT 2 Controls Branch 6-3 ricere 6.2-t of f ii, oronint:nn for r cilte, Ma"aE'***t and Technical Support

PLANT FactJTV ORGANIZATION-StouOTAN O

C*.

SurT.RhTC%DEhf O

=<

b I~ 6iv M N Oa----]

8 NUCLEAR POWER g

lOU4UTV ASSUR4NCEl 8

ANO CCuMtANCE t _ _ e NCN. _ _;

N

. AN A c,0 p - _ _CHE.F TECHNCAL l

SUPPORT 0

pgm ouAm OUAUTY

_ _ _ _ _ _o"5f'

  • Au= ANCE ST Aw i A=WANCE Cn OuS rE L---

e uANAGER

~0ue~otNi D

SAFETY ENahELRWG cReur s'rtava m Offsite

~~--OUAlfTY ASSWANCE

"""-~g-""~""""

l SECruN Onsite

~~

ASSW ANCg DNdO'F~]

OUAUTV COORONATOR a

e ASSURANCE g

FELD SERvCE$ 8 8

EM MER$

    • --.R-' ' - * * - - '

I e

s t

ENGINEERING & OPERATIONS HEALTH & SAFETY SERVICES MAINTENANCE I

I I

I ASSAST ANT ASS &STANT ASSGTANT p-.

_q FELD PLANT PLANT EdV1 SON OF PLANT g

SERVICES SuPERNTE NDENT SLPERENNT l POWER SYSTEMS I SLPERNTENDENT 8

L _ _CPERATIONS__ ___J l

l r DWCN OF-----

r--------

r_________l l

f g

g 8 PUBLC SAFETY 3 e

g uECCAL uCDCAL SECLitrTY

---4 I

SERvCE S E NGedE ERING i

OPERArCNS 8

t l

uECHANiCAL MSTRUMENT ELEC TRC AL k - _SERvCE S L----_____:

PSO

-_____J u nurENANCE uAmrEwANcE uAnTENANCE SECT ON SECTON SECTON SECTION

' SECTION SWER vtSOR SWERvtSOR gan SUPERVISOR SUPERVISOR StpERyisoR I- - WCN OF----

7 i-OfvtSCN OF---**-7 C

f g

g HE ALTH POWER g

6 OCCLPA TCNAL RO M W pyyggg

====.

STORES 9

g CHEWCAL UNif '

I HEALTH & SAFTTY I 8

M M

CAL TECHNICAL NS L------

a L _ _a SERVICES g

C, 7 S

_______J n>REuEN rOREuEN FORE e SuPLnviSOR SE CToM SUPERvaSOR g,g 01 AFT $uCN CRAFTSuDe CRAFTSuCN

~ ~ M[~ l cryiS TRAhNG t

I NUCLEAR POWER

"" l ENGNEERNQ 4

$NFT ENCNEER

- - ~ ~ - - - -,

l JANITORIAL &

ADM GM_T_"_'_ j TEST UNIT SnO LA80RER SERVICES l

Sin Rvism LEGEND:

A Ss T. $m l

7__

y tNce.EER RtACTcR san

.SArtTv

n. A T uANAG'"*"'

!l.._, el Offsite

  • Responsible for ENGhEERNG UNIT ENGPEET34G COuPUANCE SERVCES SUPERVISOR SUPERv50R SUPER WISOR SUPERVtSOR Communication uwTOPERATOR
    • ISEG functions are Reporting performed by PLANT Figure 6.2-2 COMPLIANCE STAFF

ADMINI5TRATIVE CONTROLS 6.2.3 INDEPENDENT SAFETY ENGINEERING GROUP (ISEG)

FUNCTION

~

~~~

6.2.3.1 The ISEG shall function to examine plant operating characteristics, NRC issuances, industry advisories, Licensing Event Reports and oth'er" sources which may indicate areas for improving plant safety!

The ISEG functions are performed by the Plant Compliance Staff.

COMPOSITION 6.2.3.2 The ISEG shall be composed of at least five dedicated full-time engineers located onsite.

RESPONSIBILITIES 6.2.3.3 The ISEG shall be responsible for maintaining surveillance of plant activities to provide independent verification *.that these activities are performed correctly and that human errors are reduced as much as practical.

AUTHORITY 6.2.3.4 The ISEG shall make detailed recommendations for revised procedures, equipment modifications, or other means of improving plant safety to the Assistant Director for Maintenance and Engieering of the Division of Nuclear Power.

6.2.4 SHIFT TECHNICAL ADVISOR (STA)

6. 2. 4.1 The STA shall serve in an advisory capacity to the shift supervisor on matters pertaining to the engineering aspects of assuring safe operation of the-unit.

6.3 UNIT STAFF OUALIFICATIONS 6.3.1 Each member of the unit staff shall meet or exceed the minimum qualifications of ANSI N18.1-1971 for comparable positions and the supplem' ental requirements specified in Section A and C of Enclosure 1 of March 28, 1980 NRC letter to all licensees, except for the Health Physicist who. shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975.

^Not responsible for sign-off function.

SEQUOYAH - UNIT 2 6-9

ACMIf1ISTRATIVE C0flTROLS 6.4 TRAltilflG 6.4.1 A retraining and replacement training program for the unit staff shall be maintained under the direction of the appropriate Assistant Plant Superintendent and shall meet or exceed the requirements and reccommendations of Section 5.5 of ANSI N18.1-1971 and Appendix "A" of 10 CFR Part 55 and the supplemental requirements specified in Section A and C of Enclosure 1 of the March 28,1980 NRC letter to all licensees, and shall include familiarization with relevant' industry operational experience identified by the ISEG.

6. 5 REVIEW Af1D AUDIT

~

6.5.0 The Manager of Power is responsible for the safe operation of all TVA power plants. The functional organization for Review and Audit is shown on Figure 6.2-1.

6.5.1 PLAf1T OPERATI0t15 REVIEW COMMITTEE (PORC)

Fut4CTI0tl 6.5.1.1 The PORC shall function to advise the Plant Superintendent on all matters related to nuclear safety.

COMPOSITI0t1

6. 5.1. 2 The PORC shall be composed of the:

Chairman:

Plant Superintendent Member:

Operations Supervisor Member:

Engineering Supervisor Member:

Instrument Maintenance Supervisor Member:

Electrical Maintenance Supervisor Member:

llealth Physics Supervisor Member:

Quality Assurance Staff Supervisor Member:

Mechanical Maintenance Supervisor SEQUOYAH - UtlIT 2 6-10