ML20053D706

From kanterella
Jump to navigation Jump to search
Informs of Completion of Review of All safety-related Equipment,Except Equipment Supplied by Bailey Controls,For Defective Cutler-Hammer,type M Relays W/Dc Coils.All Future Orders Will Specify Use of Unacceptable Relays
ML20053D706
Person / Time
Site: North Anna Dominion icon.png
Issue date: 05/24/1982
From: Spencer W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-SSINS-6820 299, IEB-78-06, IEB-78-6, NUDOCS 8206070233
Download: ML20053D706 (1)


Text

,

' NRC REGI'>tt

'NTA. E rn:..

VIMUINIA ELucrusc ann l'ownu COMPANY

"'"" M",'hl'y'"'t) "." 2 t'

...m. c.......

May 24, 1982 v.. r.......,

Mr. James P. O'Reilly Serial No. 299 Regional Administrator PSEAC/CGC:bw U.S. Nuclear Regulatory Comission Region II 101 Marietta Street, Suite 3100 Docket No. 50-404 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

DEFECTIVE CUTLER-HAMER, TYPE M RELAYS WITH DC COILS IE BULLETIN 78-06 M

By letter Serial No. 449, dated August 4,1978, we indicated that we had not comptsted our review of the captioned bulletin for North Anna Units 3 and 4.

During the North Anna 3 and 4 Coal Coversion Study, this bulletin was placed in our " Delay File".

We have recently mopened our review of this bulletin. We have completed our review for all safety-mlated equipment, except that supplied by Bailey Controls, and have detemined that none of it uses the subject relays.

We am pmsently consideriag upgrading and/or mplacing the Bailey equipment. Themfore, we plan to defer our review of the Bailey equipnent until a decision is made on the extent of its actual use on North Anna 3.

We will submit a final report on this matter at that time.

As we stated in our previous letter, all futum orders for North Anna 3 will specify that the use of these_ relays is unacceptable.

If further information is needed, please contact us.

Very truly yours, ll Ofotct /

W. C.

encer 7

cc: Mr. Robert L. Tedesco Division of Licensing 8206070233 820524 DR ADOCK 05000404 Ihll PT@