ML20053C873

From kanterella
Jump to navigation Jump to search
Provides Addl Response to NUREG-0737,Item II.K.3.3 Re Reporting of Relief & Safety Valve Failures & Challenges,Per 820303 Request
ML20053C873
Person / Time
Site: Oyster Creek
Issue date: 05/26/1982
From: Fiedler P
GENERAL PUBLIC UTILITIES CORP.
To: Crutchfield D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.K.3.03, TASK-TM NUDOCS 8206030088
Download: ML20053C873 (1)


Text

_ _ _ _ _ _ _ _ _

GPU Nuclear Q

g7 P.O. Box 388 s

Forked River, New Jersey 08731 609-693-6000 Writer's Direct Dial Number:

May 26, 1982 Mr. Dennis M. Crutchfield Operating Reactor Branch #5 Division of Licensing U.S. Nuclear Regulatory Cmmission Washington, D.C.

20555

Dear Mr. Crutchfield:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219

'IMI Action Plan Item II.K.3.3 Your letter of March 3,1982, requested further information concerning our response to NUREG 0737, Its II.K.3.3, Reporting of Relief and Safety Valve Failures and Challenges.

It is our intention to repoit the requested information as follows:

Challenges to safety or relief valves which require the subnitting of an LER as defined in the Oyster Creek Operating License and Technical Specifications, will be subnitted as such. Challenges which do not constitute an LER will be the subject of a special report subnitted to NRC, Pagion I within 60 days of the occurrence.

Should you have any further questions concerning this its, please contact Mr. Michael Laggart of my staff at (609) 693-6932.

Very truly yours, b

9 Petef B. Fiedler Vice President and Director Oyster Creek PBF:BH:1se

{

cc:

Mr. Ronald C. Haynes, Adninistrator

  • L Region I U.S. Nuclear Eegulatory Conmission
  1. 0 631 Park Avenue King of Prussia, PA 19406 NRC Resident Inspector Oyster Creek Nuclear Generating Station Erked River, MT 08731 8206030088 820526 PDR ADOCK 05000219 P

PDR GPU Nuclear is a part of the General Public Utihties System l