mur DOCUMENT NO.

80A4437 REV.

I 11 NUCLEAR ENERGY SERVICES, INC.

PAGE 1

OF 17 O

PRESERVICE INSPECTION AUTOMATED EXAMINATIONS SCAN PLAN FOR REACTOR VESSEL WELDS LONG ISLAND LIGHTING COMPANY SHOREHAM NUCLEAR POWER STABON UNIT 1 CONTROLLED CD?Y VALD ON.Y F THS STAMP S rid Preie:: A:Olication Preparec By

' Date

~-

3336 OJfU.

GAc o'd 30 Ea /?fri APPROVALS

{

Ti7 t gf a g pT, l

5iGNATUPE i

DATE l

/O.

/

o n

ISI Auto. Oper. Mg-arry A

n i

,,2 Martens //y' /,/ #M)

/ 6 / 2 /Il Is1 s v. s t. De.= t. Mer.

G.

Om%~->

io /a/m m,. n.

c.M=,-

i M

ngr.

a. ciidert e

/$ dhs~4 1/e + 4' I

c.

x=_.

v. vctent LILCC d2A
e. thdls &fEblI

~

H+ 7/

la

'1 h

F O R M

  • N E S 204 2 *O

) {-

1-

' " - ~ ' - '

NUCLEAR ENERGY SERVICES. INC.

PAGE 2

CF 17

=

.f 7.7 l f

f CATE C E $ C R I P T l C ;;

ApppoyAt

(

j

') 'W p/.

{

/m 4/1*/82 Rcvised in accordance with CRA 2370.

)

/

y

' //L/ lA J' 1-l

'f y)Qg; j n.n /

/

    • *"c ' '.'e a can para =eter changes to r

43,g. yz I

l l

incorporate field changes

.'C-1 thrct:gh l

I i

I l'

l FC-7.

I I

j I

e L G _" ~~crrec'wiOn - Appe.7d I y.

A i

I I

l i

I i

6 i

i I

i

[

g i

l i

l

[

l i

l I

i l

l I

i l

I i

i i

i l

l t

i i

h I

s l

5 l

I.

<m l

l

)

I i

(,

s l

l I

I I

l i

i I

i l

e i

i l

i W

l i

l i

1 e

t i

i t

6 I

I i

i l

i i

t i

i i

l I

i i

I k

s k

s

,x i

i f

a 1

l

80A4437 DOCUMENT NO.

m 11 3

U PAGE OF NUCLEAR ENERGY SERVICES. INC.

'O v'

TABLE OF CONTENTS Page 1.

SCOPE 4

2.

REFERENCES 4

3.

EQUIPMENT 5

4.

SCANNING SEQUENCE

SUMMARY

5 5.

GENERAL PROCEDURE FOR SETTING OF POSITIONAL REFERENCE 12 (Sled Location)

LIST OF FIGURES AND TABLES Table 1 A Area of Examination - Vertical Welds 6

Table IB Area of Examination - Circumferential Welds 7

Figure 1 Extent of Coverage in the X Direction for Vertical Welds 8

(1-308A through H and J)

Figure 2 Extent of Coverage in the X Direction for Vertical Welds 9

p)

(1-307A, B, C) n Figure 3 Extent of Coverage in the Y Direction for Circumferential Welds 10 (4-30SA and B)

Figure 4 Extent of Coverage in the Y Direction for Circumferential Welds 11 (1-313)

Figure 5 Sled Postions and Distances from Track Q with 40" Arm 13 (Vessel Scanner - Upright Position)

Figure 6 Sled Positions and Distances f rom Track Q with 26-1/2" Arm 14 (Vessel Scanner - Upright Position)

Figure 7 Permanent Track Azimuths and Sled Elevations (Vessel El.)

15 (Vessel Scanner - Upright Position)

Figure S Permanent Track Azimuth of Sled Elevations (Vessel El.)

16 (Vessel Scanner -Inverted Position)

Figure 9 Shoreham Unit 1 Roll Out View 17 APPENDICES m( )

A Scan Sequence Sheets x_

B Weld Scan Check-Off Sheets FC=iA = NES 2C5 2lSO

80A4437 DOCUMENT NO.

mer 11 PAGE OF 17 4

NUCLEAR ENERGY SERVICES, INC.

m.l PRESERVICE INSPECTION AUTOMATED EXAMINATIONS SCAN PLAN

1. SCOPE 1.1 The automated examinations scan plan herein is the scanning sequence for the Reactor Pressure Vessel (RPV) Shell Welds, excluding the lower head meridional welds. The scan plan specifies the welds to be examined, area of examination for each weld, the scanning sequence to be followed for this examination and other pertinent data. The scanning sequence allows for as complete coverage as possible of each weld from one or more permanent tracks.

1.2 The plan will be modified as required when as-built conditions dictate the need for such modifications and will be presented as a final report after the examinations are finished.

The report will serve as the basis for ISI considerations.

2. REFERENCES o

The following documents form a part of this scan plan.

L) 1.

ASME Boiler and Pressure Vessel Code,Section XI, 1971 Edition and Summer of 1972 Addenda 2.

ASME Boiler and Pressure Vessel Code, Section 111, 1971 Edition and Summer of 1972 Addenda 3.

NES Document 80A0482, Preservice Inspection Program Plan, Unit 1 (Latest Revision) 4.

NES Document 80A0480 Automated Ultrasonic Examination Procedures for Reactor Vessel Welds 5.

NES Document 80A443S, Report on the Shoreham Vessel Scanner On-Site Fit-up Procedure (Latest' Revision) 6.

NES Drawing SOE3710 RPV Rollout Shoreham 1 (Latest Revision) 7.

NES Drawing 80E3696 Scanner Track System Locations Shoreham I (I.atest Revision)

S.

NES Drawing SOE3719 Vessel Scanner Outline Drawing Shoreham (Latest Revision) 9.

NES Drawing 80D3700 Scan Path Layout RPV Sled Attitude Horizontal f-(3)

Shoreham 1 (Latest Revision) 10.

NES Drawing SOD 3704 Scan Path Layout RPV Sled Attitude Vertical Shoreham 1 (Latest Revision).

l ROC'i:NES 2:5 2 'SO

80A4437 DOCUf. INT NO.

au 11 5

PAGE OF 17 NUCLEAR ENERGY SERVICES. INC.

mO

3. EQUIPMENT 3.1 This examination is to be performed from the OD of the RPV.

3.2 The vessel scanner travels in the vertical plane on permanent tracks attached to the RPV biological shield wall. This motion is denoted Y, with the 0" RPV elevation as its starting point, Y increasing with elevation above this point.

3.3 The sled / transducer assembly is mounted on the movable arm of the vessel scanner, allowing travel in the horizontal plane. This second motion is denoted X, with the 0 azimuth of the RPV as its starting point, X increasing with clock-wise rotation around the RPV.

3.4 A third motion is denoted Z, which is movement of the arm and attached sled in the radial (in and out) direction. This movement is to insure sufficient contact between the sled and the OD surface of the RPV.

4. SCANNING SEQUENCE

SUMMARY

4.1 The examination scanning sequence has been developed to fulfill several n

! )

objectives: to keep ultrasonic calibrations to a minimum, to have as few equipment changes as possible, and to lessen movement around the RPV.

4.2 Based on these criteria, the examination should be performed on a track-by-track basis around the RPV, first from the top of the vessel with calibration block SNPS-6.

Next, calibration block SNPS-7K is utilized to complete the examination from the top of the RPV. The equipment is moved to the bottom of the RPV and the examination is finished with calibration block SNPS-7K.

Calibration is then performed with SNPS-6 and the examination completed from the bottom of the vessel.

4.3 The Scan Sequence Sheets list the scans required from each track, depending on the calibration block used. The page number of the sheet will prefix the scan number to form a unique number for that scan. Each scan has calculated values already entered. Below these entries are spaces for recording the actual values used, if they differ.

4.4 Following the Scan Sequence Sheets are the Weld Scan Check-off Sheets. Tht.se sheets form a part of the data review process, and list the scans needed to complete cach weld, based on the calibration block required and the direction of the scan. By recording the actual values for each scan on the appropriate sheet (s), a record of the completion of each weld is obtained.

(o3 F C C '.' : NES 205 2 60

DOCUMENT NO.

80A4437 mur 11 NUCLEAR ENERGY SERVICES. INC.

(<

TABLElA AREA OF EXAMINATION - VERTICAL WELDS 5-7/8" SHELL COURSE (See Figure 1)

Weld No.

[

Exam Coverage Y" 1 Scan Path XO Scan Path XO

=

From To From To From To l-308A 300 553 613 24.75 35.25 28 32 1-308B 1500 553 618 144.75 155.25 148 152 1-30SC 2700 553 613 264.75 275.25 268 272 1-30SD 00 403 553 354.75 5.25 35S 2

1-308E 1200 403 553 114.75 125.25 IIS 122 1-308F 2400 403 553 234.75 245.25 238 242 p

1-308G 300 253 403 24.75 35.25 28 32 l-30SH 1500 253 403 144.75 155.25 148 152 1-308]

2700 253 403 264.75 275.25 26S 272 6-7/8" SHELL COURSE (See Figure 2)

Weld No.

[

  • E" 1

^" ^

^*

From To From To From To 104 140 l-307A+

1So 11.75 24.25 15.5 20.5 227 253 1-307B 13S0 104 253 131.75 144.25 135.5 140.5 1-307C 25S0 104 253 251.75 264.25 255.5 260.5 D0 The other areas of the weld were examined manua'ly.

F CC'.* : '.E 5 2 ~ 5 50

DOCUMENT NO.

80A4437 11 av PAGE 7

OF 17 NUCLEAR ENERGY SERVICES. INC.

l p

d TABLEIB AREA OF EXAMINATION - CIRCUMFERENTIAL WELDS 5-7/8" SHELL COURSE (See Figure 3)

Weld No.

Q Exam Coverage XO 1 Scan Coverage Y"

= Scan Coverage Y" From To From To From To 4-308 A

  • 553" 340.03 26.65 542.5 563.5 548.75 557.25 4-30S A
  • 553" 106.41 115.37 542.5 563.5 548.75 557.25 4-30SA*

553" 245.40 278.02 542.5 563.5 548.75 557.25 4-30S B

  • 403" 359.95 35.52 392.5 413.5 398.75 407.25 4-30SB
  • 403" 106.41 124.24 392.5 413.5 393.75 407.25 4-30SB
  • 403" 147.81 165.64 392.5 413.5 398.75 407.25 4-30SB+

403" 236.53 254.36 392.5 413.5 398.75 407.25 4-308 B

  • 403" 266.10 283.93 392.5 413.5 398.75 407.25 nL]

5-7/8" 7/8" SHELL COURSE (See Figure 4)

Weld No.

[

Exam Coverage XO 1 Scan Coverage Y"

= Scan Coverage Y" From To From To From To 5-7/8" Shell Course 5-7/8" Shell Course 1-313+

253" 17.700 35.520 251.75 263.5 253 257.25 1-313*

253" 127.110 165.640 6-7/S" Shell Course 6-7/8" Shell Course 1-313+

253" 245.400 283.930 241 254.25 24S 253 q

The other areas of the weld were examined manually.

+

(/

FCCM :NES 205 2/80

DOCUMENT NO.

80A4437 Auer 8

O F_17 PAGE NUCLEAR ENERGY SERVICES, INC.

O 5.25 5.25 2*

2*

/

.l /l

/,

1

//

45 L, yyy g,Y 4M g

yyy 0**

45 45* =

0*

=

5 7/8"

/)

/

/

LEGEND 5/16" Cladding i

Perpendicular to Weld Parallel to Weld

=

O' Base Material h'RV Weld and Required Volume Note:

1 = 2.0289" O

FIGURE 1.

EXTENT OF COVERAGE IN THE X DIRECTION FOR VERTICAL WELDS l-308A THRU H AND J (TYP.)

FCOY :NES 205 2/80

DOCUMENT NO.

80A4437 9

17 PAGE OF NUCLEAR ENERGY SERVICES, INC.

O fr 6.25*

6.25 2.5 2.5*

i

\\

\\

N V,

/

/

1

~

T 45*{_

0 WRV O WRV 0**

45* =

l 5

0*

6 7/8"

=

O

//

/l 1

1 7

LEGEND 5/16" Cladding

__l Perpendicular to Weld Parallel to Weld

=

O Base Material

/

WRV Weld and Required Volume

]

Note:

1* = 2.0289" O

FIGURE 2.

EXTENT OF COVERAGE IN THE X DIRECTION FOR VERTICAL WELDS 1-307A, B, AND C (TYP.)

FCW = NES 205 2/80

DOCUMENT NO.

80A4437 PAGE 10 OF 17 NUCLEAR ENERGY SERVICES, INC.

O 5 7/8"

, _ 5/16" Cladding h

t' l

?

0**

b 45 _L 0 WRV 10.5"

/

45" =

l 4.25" r/

/

/

WELD n

/

/

4.25"

/

O WW

./

10.5" 45

=

45*_L O**

1.

Perpendicular to Weld Parallel to Weld e

f

\\1 0* Base Material

-[

WRV Weld and Required Volume O

FIGURE 3.

EXTEtJT OF COVERAGE 111 THE Y DIRECTIOt3 FOR CIRCL"EERE';TIAL WELDS 4-308A A!:D B (TYP.)

FCt'.1:NES 205 2/80

DOCUMENT NO.

80A4437 mmr PAGE 11 OF 17 NUCLEAR ENERGY SERVICES. INC.

O 5 7/8" 5/16" Cladding 0*

g 45*1 0* WRV 11.75"

/

45

=

4.25"

/

// / / / /

s"_

s" r/uff s

1 2s"

/

13.25" 5.0" O

/

O' WRV r

45* =

4 5

  • _1_

s oo.

LEGEND 1

Perpendicular to tveld Parallel to Weld

/

/

=

\\/

0* Base Material WRV Weld and Required Volume O

FIGURE 4.

EXTENT OF COVFRAGE IN TifE Y DIRECTIOS FOR CIRCUMFERE!:TIAL WELD l-313 FOA'.1:NES 2C5 2/80

DOCUMENT NO.

80A4437 nw 11 1

17 PAGE OC NUCLEAR ENERGY SERVICES, INC.

OO

5. GENERAL PROCEDURE FOR SETTING OF POSITIONAL REFERENCE (SLED LOCATION) 3.1 Determine requirements for scanner and sled from Scan Sequence Sheet.

5.2 Adjust scanner for correct mode (upright or inverted) and direction of rack teeth (see Figures 7 and 8).

5.3 Install required arm on scanner.

5.4 Install sled in the required position and orientation (see Figures 5 and 6).

5.5 Install scanner from the top or bottom of track.

5.6 Install temporary top stop (80D3711) as required (see Figures 7 and 8).

3.7 Run scanner to primary positional reference for Y (top or bottom stop) with Z motion retracted and set encoder to given value (see Figures 7 and 8).

5.8 Run arm / sled to primary positional reference for X (extended or retracted) and set encoder to given value (see Figures 5 and 6).

()

5.9 Secondary positional references may be used as needed.

o LJ CC=.V = NES 2 ^ 5 2:E3

DOCUMENT NO.

80A4437 DAGE 13 op 17 NUCLEAR ENERGY SERVICES. INC.

h :-

Max. Ext. +15.76*

Max. Ext. -15.76*

Retracted +1.50' Retracted -1.50*

Max. Ext. +14.92*

Max. Ext. -14.92*

Retracted +.66*

Retracted

.66*

Pos 6 Max. Ex.t. +10.05 i

1 -4.21* Retracted Pos 7 I

. Max. Ext. -10.05* -

+4.21 Retracted Max. Ext. i7.13

% p. Both

+

Sides of Track

[I

~

i t

]

a--

- l

- l

_l i

g C C C

V)

] }

Y

.d_

(

_C_

I Posn Posn Posn Posn Posn Posn Posn brJ I.,

1 2

6 3

7 4

5 r

i

/

View Looking into Vessel-(typ.)

~

FIGURE 5.

SLED POSITIONS AND DISTANCES FROM TRACK WITH 40" ARM.

VESSEL SCANNER - UPRIGHT POSITION FCOM:NES 205 2,63

DOCUMENT NO.

80A4437 m

PAGE 14 OF 17 NUCLEAR ENERGY SERVICES, INC.

GV (4

Track Max. Ext.

+9.29*

Max. Ext. -9.29*

Retracted +1.50*

Retracted -1.50*

Max. Ext.

+3.90*

Typ. Both Sides of Track l

W b

t i

i I

I A

}

~

i i(

b, U

+

7 l

l d,_ ]

l Posn Posn Posn 1

2 3

i View Looking into Vessel (typ.)

O ig FIGURE 6.

SLED POSITIONS AND DISTANCES FROM TRACK /

WITH 26 1/2" ARM VESSEL SCANNER - UPRIGHT POSITION FCO'/. :NES 205 2/80

DOCUMENT NO.

80A4437 11 NUCLEAR ENERGY SERVICES, INC.

O LJ Track Direction of Scanner at Scanner at Type of Azimuth Rack Teeth **

Top Shop Bottom Stop Bottom Stop A

0 M

622.05 384.93 Round N

220 f

146.68 49.06 Flat A

24o M

  • 622.19 230.93 Round 598.10 384.93 Round 113o 135 279.68 49.15 Flat

/

157o M

  • 622.19 252.93 Round

/1 24'o M

598.10 384.93 Round p)

N A.

255a f

279.68 49.15 Flat 598.19 537.11 Flat 270a 274*

437.20 252.91 Round N

347 P

622.19 537.15 Flat

  • Elevations shown with temporary stop 80D3711 Installed (Z motion retracted)

Indicate direction rack teeth on track are facing, view looking towards vessel

(.s FIGURE 7.

PERMANENT TRACK AZIMUTHS AND SLED ELEVATIONS (VESSEL EL. )

VESSEL SCANNER - UPRIGHT POSITION

)

FORM : NES 205 2/80

DOCUMENT NO.

80A4437 NUCLEAR ENERGY SERVICES. INC.

O Track Direction of Scanner at Scanner at Type of Azimuth Rack Teeth **

Top Shop Bottom Stop Bottom Stop A

0*

597.80 358.31 Round N

22*

F 120.06 24.81 Flat 24 597.94 204.31 Round 113*

573.85 358.31 Round N

135*

F 253.06 24.90 Flat 157 597.94 226.31 Round 247 573.85 358.31 Round N

255 7

253.06 24.90 Flat L'

N 270 V

573.94 512.36 Flat N

274*

F 412.95 226.27 Round 347*

597.94 512.90 Flat Elevations shown with temporary stop 80D3711 Installed (Z motion retracted)

    • Indicate direction rack tech on track are facing, view looking tcward vessel N

1 O

FIGURE G.

PERMAIJEt!T TRACK AZIMUTH Al3D or SI.r 0 ELEVATI !;3 (VESSEL EL. )

I VESSEL SCA!;!iER - ItNERTED FOSIT70N I

FCW = NES 205 2/SO

i T

.-s

-. =.,,

j

!Z-l

  • g es ;

= =j.

f 6

s a

qc n

is e

e 2

s aWag3 1)

.>v i

i

%- --_]3 l

t 4MEI*

9 J

Q9~

j y -s5.{

J i

'es '-

%'.'9 j

i

!E$ggi$

>=

r-C sn s

e=usg y O

Lu.. 1

~

+

v.X -- "sC93v g ',, s. f g g j

! ='

-=

T N

+

    • ge

'.g 7,

i...j a

10;;i5s q

O

'ce _

__.5 I

H 4. !.

t' i

v p

so,gi{

=y 3'

A.'.---J.j "A

w: i-m.

J,f Iz

$ uJ O

2 rv:,.s ; 7 3 j

4

-f *

'4

= O-5 2

p.,C C C

~

4 4

a 3 c z

.s T C.i 4

~

z

~- -,

uJ a

'a i,.,

f g

a O"

t 9j a

2 I9 M!

~

a:

v3 -

ol E!

oto w

y;

^ **

~}-5 5s3 qm [2 lg 6

g LO o

'I 4

i, r.,

m --

g o.

o E

x z or,-

=

jOf i

.E T 2

" ' 3%'

f* M3'

' 'd

~= w h i

f

.a.

==

~

e O

. y.M E --- -

"C

~

~~

d r 9:Cs w,3, f.

~

o t%

"}

.Cr ' s s

h,,

  • q Q

a

,g m w mw !

we g

m !Ct

, N,* P_

l--__

~

a mv a

(, % D t

P' g

j I

c d

'T E

2 O

4

' E D

[.

}

o y

s_

-~

.a e.

7 3

5

%e o '*

!E rk.

g,

i. o j.

n y

s a

u 3

N 2

2 I)T g

0 9

.a u.

r l*

N 3

3 O

C +

N Q

b h

= 9 a)

T

'b Q

-m.

O' Z

0 2

w e

e

~

m a

O m,

s

- 4_

d z

s y

g

,3

.s J y" O g g. E==

g t

v,

.N s/.

2 N

/

12 ;

=

i

1.,

u, -.g a r g a..

"a

-O

-T 3 tg a'"d.

O 2

irs

-E

}

j=0a V,

y 0

3.u*3

.- u N

- 2 N

,E

'C

~

Eh b f$ b $ ht; " In-ig s T I

s N7 i W g DN mv r

=*

e

!F a*

'Ibb s4

.017-3

  1. lIb$

U h N,, SW R,===

7'; &

OE 1 JL.N 4 ON G134 0

aO.;{=g;.E.<:.h EI a f z S, gg

~

N 3

385 A

-=

c o-

- y A

['

TC 4 N' F 3 "i

( ; "' ? C N y y,'

N I

E p

g

/

r <- c d) -

j D

rU l$ # lE Y 9*

A b

49 a r 7

I.

9.

's

)-.O sd -

2 c 21 z of

  • l0 e

~

2 i

w n

  • o I

e y*

-2 i = 4 !=

4 E

$5 -

$ 5 Z l$

E, "i

sa i

s e - N !

N

's g

u a

j.)

c a

I C,

= 4.; < : :. -

23 i;

5 1 t, o;

o

- 2 !9 z 3 E! E L

o 1 l

u, m :,.;

wv y

eJ i

?

~)

h-m u@ v C')

Ch W

Gw C a

g*

u~ *

~

_e-

}9 i

i

<-]

I C

z w

w w

..n w

1 o

o

- o a.A

~

z t

r Yj 0

. # n N O sT

'- N $

y I

..,m e-am.a f

-s m.

/_,:

l N

f

(

V.

I i\\,,

- s s

. h. I J

\\

~

DOCUMENT NO.

80A4437 mer 11 NUCLEAR ENERGY SERVICES, INC.

O APPENDIX A SCAN SEQUENCE SHEETS O

i l

FC:y = NES 205 2/80

DOCUM ENT.NO.

80A4437 N

NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 147*

Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

A Proc. No. 80A0480 Rev. 2 Comp /Syst.

Automated From Top of vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary Seccndary Seconcery Scanner Sled Pos. Ref Y" Pos. Ref X Pos. Ref Y" Pos. Ref X*

Mode Arm Posn Top Stop Arm Retracted Bottom Arm Extended Stop Inv.

40" 6

597.94 336.95 I

512.90 351.21 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

1-347-1 Vert.

340.03 l 351.21 542.5 563.5 X

.36' 4-308A

.1_

1-347-2 Hor.

340.03 351.21 542.5 563.5 Y

.75" 4-308A

=

4 L

/1\\

/1\\

l l

l l

Operator Date l

FOW.1 = NES 205 2/80

I i

my DOCUMENT NO.

80A4437 l

39 NUCLEAR ENERGY SERVICES. INC.

PAGE OF l

SCAN SEQUENCE SHEET O

Track (

Plant / Unit LILCO 347*

Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

W Proc. No. 80A0480 Rev. 2 Comp /Syst.

Automated From Too of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary Secondary Seconuary Scanner Sled Pos. Re f Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode Arm Posn Stop Arm Retracted Arm Extended Stop 40" 4

597.94 347.66 512.90 361.92 Inv l

Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

To X/Y l

No.

ATT From To Frcm AMT Weld Dir.

1-147-1 Hor 351.21 354.75 542.5 563.5 Y

.75" 4-308A

=

l 1-347-4 Vert 351.21 358.0 542.5l563.5 x

.36 4-308A 3

I t

Operator Date FORM 2 NES 2C5 2/80

DOCUMENT NO.

80A4437 39 PAGE 3

op NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track (

274*

Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev. 2 Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y" Pos. Ref X*

Pos. Ref Y" Pos. Ref X Top Stop Arm Retracted Bottom Arm Extended Mode Arm Posn Stop Inv.

40" 7

412.95 269.79 l

226.27 284.05 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks Froml No.

AM From To To X/Y AMT Weld Dir.

2-274-1 Vert. 269.79 283.93 251.75 263.5 X

.36*

1-313 I 1

, _ vp r 2-274-2 Vert. 269.79 - 283.93 392.5 413.5 X

.36*

4-308B

_L l-308J

=

l l

I2-274-3 Hor.

269.79 283.93 253.0 257.25 Y

.75" 1-313 l-308J

_L 2-274-4 Hor.

269.79 283.93 398.75 407.25 Y

.75" 4-308B

=

1-308J

_L l

l Operator Date FCR*.i:NES 205 2/50

DOCUMENT NO.

80A4437 4

PAGS' Cc 39 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 274 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Ton of Vessel Cal. Block No.

SNPS g RPV 00 Exam Positional Reference Primary Primary Secondary Seconaary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode l' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop TNV 40" 6

412,os 7n a,os

??6.27

??R.21 Scan Sled Scan X*

Scan Y" Index Coverage For Pemarks Froml To X/Y AMT Weld Dir.

No.

ATT From To 3-274-5 7ert.

263.95 269.79 251.75' 263.5 X

.36*

1-313

_L

[1\\

, - 30 8J 1

=

i 1-274-6 Vert.

269.0 272.0 263.5 192.5 X

.36 1-308J

=

s 3-274-7 Vert.

266.10 269.79 392.5 413.3 X

.36 4-308El

_1_

[}\\

1-30 8J

=

3-274-8 Hor.

263.95 269.79 253.0 l257.25 Y

.75" l-313 1-308J

_l-l 3-274-9 Hor.

264.75 275.25 257.25 798.75 Y

.7E" 1-3083

_1_

3-274-10 H7r.

264.75 269.79 398.75 403.0 Y

75" 1-308J

_L l

[1k 4 't9PP 3-274-11 Hor.

266.10 269.79 403.0 407.25 Y

.75" 4-308B

=

l 4

i

)'

i 1

Operater Date_.

j FORM = NES 205 2/50

DOCUMENT NO.

80A4437 m

me -

b PAGE 5

OF 39 NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track (

270 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

ii*

Proc.

No._ BOA 0480 Rev. 2 Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS ~ 6 RPV OD Exam Positional Reference Primary Primary Secondary beconaary Scanner Sled Pos. Ref Y" Pos. Ref X

  • Pos. Ref Y" Pos. Ref X*

l Arm Poca Top Stop Arm Retracted Bottom Arm Extended Mode Stop Inv.l 40" 7

573.95 265.79 512.86 280.05 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

lDir.

No.

AS'T From To From To X/Y AMT Weld 4-270-1 Hor.

265.79 278.62 548.75 557.2!

Y

.75" 4-308A 1-308C

~_L 4-270-2 Hor.

265.79 275.25 557.25l 573.95 Y

.75" 1-308C

_L l

h

-270-3 Vert. 265.79 278.92 542.5 563.5 X

.36 4-308A L

[lk l-308C

=

I 4-270-4 Vert. 258.0 272.0 562.81l 573.95 X

l.36*

l-308C

=

l l

Operator Date l

l FORM:NES 205 2/60

DOCUMENT NO.

80A4437 29, mm y

me,

)

I h

1 39 PAGE 6

OF NUCLEAR '-NERGY SERVICES, W;.

u __

5Al' SEQUE!J2E SMEET

,i S

Plant / Unit LILCO Tra + ff 270' Cal. Data Pkg. tJo.

~

e Shoreham Unit I Rack "?eeth Dir.

Proc. tJo. 80A0480 Rev. 2 Comp /Syst.

Automated From Top of Vestal Cal. Block tJo.

S!JPS - 6 RPV OD Exam Positional Reference J

Prim 1rf Primary Secondary Seconcary Scanner,,

Sled Pes. 1of Y" Pos. Ref X*

Pos. Ref Y" Pos. Ref xo Mod.-

Arm Posn Top Stop Arm Retracted Bottom Stop Arm Extended inv.

40" 1

573.95 254.24 l

512.86 268.50 Scan j Sled Scan.s*

Scan Y" Index Coverage For Remarks l

't o X/Y l

i;o.

l AT!

From o

From AMT Weld Dir.

3-270-5 _

Por.

254.24 265.79 548.75 557.25 Y

.75" 4-308A l-308C

_L 5-270-6 lia r.

264.75 265.79 557.25 573.95 Y

l.75" l-308C

_L

()5-270-7 Vert. 254.24

'265.79 542.5 l563.5 x

.36o

.;-30pn

_1_

[lh 1

l f

l l

l Operator Date FCRM :NES 225 2/50

r DOCUMENT NO.

80A4437 7

39 PAGE OF NUCLEAR ENEAGV SERVICES, INC.

SCAti SEQUE!;CE SHEE.'

Plant / Unit LILCO Track (

270*

Cal. Data Pkg. Fio.

Shoreham Unit I Rack Geth Dir.

Proc. No. 80A0480

,Re v.

2 Comp /Syst.

Automated From Top of Vessel Cal. Block t;o.

SNPS - 6 RPV OD Exam Positional Reference Primary Primary Secondary Seconaary Scanner Sled Pos. Ref Y" Pos. Ref X

  • Pos. Ref Y" POS-Ref X*

Mode l Arm Posn Top Stop Arm Retracted Bottom Stop Arm Extended l40" l'P 3

598.19 262.87 537.11 277.13 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

To X/Y l

Weld lDir.

tio.

AM Prom To From AMT 6-270-8 Vert. 268.0 272.0 573.95 598.19 X

l. 36

  • l-308C

=

6-270-9 llo r.

264.75 275.25 573.95 598.19 Y

.75" 1-308C

_L l

)

l l

l l

l l

7 Operator Date FCR'.i:NES 205 2/60

DOCUMENT NO.

80A4437 PAGE 8

OF 39 NUCLEAR ENERGY SERVICES, INC, SCA?; SEQUE!!CE SHEET e Plant / Unit LILCO Track (

247*

Cal. Data Pkg. 13 0.

Shoreham Unit I Rack Teeth Dir.

4 Proc. 1;o. 80A0480 Rev. 2 Comp /Syst.

Automated From Top of Vessel Cal. Block tio.

S!;PS-6 RPV OD Exam Positional Reference Primary Primary Secondary Seconadry Scanner Sled Pos. Ref Y" Pos. Ref X

  • Pos. Ref Y" Pos. Ref X*

P.cde I Arm Posn Top Stop Arm Retracted Bottom Arm Extended Stop Inv.l 40" 7

573.85 242.79 358.31 257.05 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

To X/Y l

?;o.

ATT From To From AMT Weld Dir.

7-24 7-1 Vert 242.79 254.36 392.5 413.5 X

.36' 4-308B

_L 7-247-2 Vert.

245.40 254.24 542.5 563.5 X

.36*

4-308A'

_b 7-247-3 Hor.

245.25 254.36 398.75 407.25 Y

.75" 4-308B

=

7-247-4

'Mo r.

245.40 254.24 548.75 557.25 Y

.75" 4-308A

=

l l

l Operator Date FCR'.* = NES 2C5 2:SO

DOCUMENT NO.

80A4437 k

D

" E" OF NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUEt:CE SHEET e

Track (

247*

Cal. Data Pkg. No.

Plant / Unit LILCO Shoreham Unit I Rack Teeth Dir.

4 Proc. 1;o. 80A0480 Rev.

2 Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS - 6 RPV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y" Pos. Ref X

  • Pos. Ref Y" Pos. Ref X*

Mode Arm Posn Top Stop Arm Retracted Bottom Stop Arm Extended Inv. l 40" 2

573.85 232.08 358.31 246.34 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

No.

A"'T From To From To X/Y AMT Weld Dir.

8-247-5 Vert.

236.53 242.79 392.5

'413.5 X

.36*

4-308B j_

[1\\

l-308F

=

8-247-6 Vert.

238.0 242.0 413.5 553.0 X

.36*

1-308F

=

l 8-247-7 llo r.

236.53 245.25 398.75 403.0 Y

.75" 4-308B 8-247-8 Hor.

234.75 245.25 403.0 l553.0 Y

.75" l-308F

_L 4-308B

=

l Operator Date FC;*.' : t.ES 205 2/60

DOCUMENT NO.

80A4437 g

9 NUCLEAR ENERGY SERVICES. INC.

SCA!! SEQUENCE SHEET O Plant / Unit LILCO Track (

157' Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev. 2 Comp /Syst.

At tomated From Top of Vessel Cal. Block No.

SNPS - 6 PPV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y" Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode Am Posn Top Stop Arm Retracted Bottom Arm Extended Stop Inv. l 40" 7

597.94 152.79 i

226.31 167.05 Scan Sled Scan X" Scan Y" Index Coverage For Remarks l

To X/Y l

No.

A *T'T Prom To Prom AMT Weld Dir.

9-157-1 Hor.

155.25 '165.64 253.0 257.25 Y

.75" l-313

=

9-157-2 llo r.

155.25 165.64 398.75l407.25 Y

!.75" u-308B

=

]

9-157-3 Ver.

152.79 165.64 251.75 263.5 X

.36*

l-313 1

9-157-4 Ver.

152.79 165.64 392.5 413.5 x

.36*

4-308B

._L l

Operator Date FCW.1 = NES 225 2;50

DOCUMENT NO. 80A4437 ae

, mir f

}

11 39 PAGE OF NUCLEAR ENERGY SERVICES, INC.

SCAtt SEQUEt;CE SHEET I

Track {

157 Plant / Unit LILCO Cal. Data Pkg. !;o.

Shoreham Unit I Rack Teeth Dir.

4 Proc. tio. 80A0480 Rev.2 Co.mp/Syst.

Automated From Tnn of 3sel Cal. Block No.

S!!PS - 6 RPV OD Exam Positional Reference Primary Primary Secondary Seconcarv Scanner Sled Pos. Ref Y" Pos. Ref X

  • Pos. Ref Y" Pos. Ref X*

Mode Arm Posn Top Stop Arm Retracted Bottom Arm Extended ggep Inv.

40" 1

597.94 141.24 226.31 1

155.5 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

No.

AM From To From To X/Y AMT Weld Dir.

10-157-5 Hor.

141.24 '155.24 253.0 257.25 :

Y

.75" l-313

=

1-308H J_

10-157--6 Hor.

144.75 155.25 257.25 403.0 Y

.75" l-308H

_L 4-308E

=

^

10-157-7 Hor.

147.81 155.25 403.0 407.25 Y

.i5" 4-3087/

=

l I

l10-157-8 Hor.

144.75 155.25 553.0 l 597.94 Y

.75" l-308E 1

l 10-157-9 Vert.

141.24 152.79 251.75 263.5 X

.36 1-313

_L 1-3081i

=

10-157-10 Vert.

148.0 152.0 263.5 392.5 X

.36 1-3081) =

10-157-11 Vert.

147:81 152.79 392.5 413.5 X

.36 4-308F

.L 1-3081

=

10-157-12 Vert.

148 0 152.0 553.0 597.94 X

.36 1-30es

=

Operator Date F C :',' :NES 205 2/SD

i DOCUNiENT NO.

80A4437 y

L i

OF M

NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track (

157 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

(o Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-6 PPV OD Exam Positional Reference Primary Primary Secondary Seconodry Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Top Stop Am Retracted Arm Extended Bottom Stop fiP 40" 5

622.19 141.24 252.93 155.5 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks Prom l To Prom To X/Y l

No.

ATT AMT Weld Dir.

11-157-13 Vert.

148.0 152.0 597.94 618.0 X

.36 1-308B

=

11-1E7-14 Hor.

144.75 155.25 597.94 618.0 Y

.75" 1-308B 1-l 9

I l

Operator Date FORM :NES 205 2/SO

DOCUMEh!T NO.

80^4437 NUCLEAR ENERGY SERVICES, INC.

SCAN SECUE!;CE SHEET Track (

Plant / Unit LILCO 113 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

f Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-6 RPV OD Exam

)

Positional Reference Primary Primary Secondary

.Seconaary Scanner

~

Sled Pos. Ref Y "

Pos. Ref X*

Fos. Ref Y" Pos. Ref X" Mode

' Arm Posn Top Stop Arm Retracted Bottom Stop Arm Extended I

T t:V 4n' 4

573.85 113.66 358.31 127.92 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks Froml To X/Y l

No.

ATT From To AMT Weld Dir.

I?-113-1 Hnr.

114.75 124.?4 39R.75 403.0 Y

.75" 4-308B

=

1'-11 n

Hor.

114.75 125.25 403.0 553.0 Y

.75" 1-308E

_l 4-308B

=

1?-133-3 vert.

114.75 124.24 392.5 413.5 X

.36 4-308B

_1.

l 1-309?

l l'

11'-4 Vort.

118.0 122.0 413.5 553.0 X

.36 1-308E

=

l 1

Operator _

Date FCO.M :NES 205 2/50

DOCUMENT NO.

80A4437 PAGE 14 OF 39 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 113 Cal. Data Pkg. No.

Shoreham Unit I Pack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary Secondary Seconoary Scanner Sled Pos. Re f Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode l' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop l40" T t:V 6

573.85 102.95 358.31 117.21 Scan Sled Scan X" Scan Y" Index Coverage For Remarks No.

ATT From To From l To X/Y AMT Weld Dir.

13-113-5 Hor.

106.41 114.75 398.75 407.25 Y

.75" 4-308B

=

13-11:-6 Hor.

106.41 115.37 548.75 557.25 Y

.75" 4-308A

=

h 13-113-7 v e,- t,

l o rs. 41 114.75 392.5 413.5 y

.360 4-3099 L

13-113-8 Vert. 106.41 115.37 542.5 563.5 X

.360 4-308A

_L l

l l

v l

Operator Date FC '.9 :NES 2C5 2'80

s DOCUMENT RIO. 80A4437 e e my W

' "1 PAGE 15 op 39 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track (

24 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

-Q Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Prunary Secondary

.Seconcary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Stop Arm Retracted Arm Extended Mode

' Arm Posn Top Bottom Stop Inv 40" 4

597.94 24.66 l

204.31 38.92 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y AMT Weld Dir.

14-?4-1 Vert.

24.66 35.52 251.75 263.5 x

.36 1-313

_I_

1-308G

=

14-24-2 Vert.

28.0 32.0 263.5 392.5 X

.36 1-308G

=

l 14-?4 1 U+ e 94.6A 35.53 392.5 413.5 v

.360 4-308B 1

l-308G

=

14-24-4 Vert.

28.0 32.0 553.0 597.94 X

.360 1-308A

=

l 14-24-5 Hor.

24.66 35.52 253.0 257.25 Y

.75" l-313

=

l-308G 1_

14-24-6 Hor.

24.75

' 35.25 257.25 l 398.75 Y

.75" l-308G

_l_

l 14-24-7 Hor.

24.66 35.53 398.75 407.25 Y

.75" 4-308B

=

l-308G

_.f_.

14-24-8 Hor.

24.75 35.25 553.0 597.94 Y

.75" l-308A

_j_

Operator Date FCP.1:NES 205 2/50

DOCUMENT NO.

80A4437 y

h R

UN NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 24 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. BOA 0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-6 PSV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y "

Pos. Ref X' Pos. Ref y" Pos. Ref X*

Mode l' Arm Posn Top Stop Arm Retracted Arn Extended Bottom Stop l40" 6

597.94 13.95 204.31 28.21

/lh TtN Scan Sled Scan X Scan Y" Index Coverage For Remarks Froml i

No.

ATT From To To X/Y AMT Weld Dir.

15-24-9 Vert.

17.70 24.66 251.75 263.5 x

.36 1-313 1

35-24-10 Vert.

13.95 24.66 392.5 413.5 X

.36 4-308B 1

15-24-11 Vert.

13.95 26.65 542.5 563.5 X

.36 4-308A 1

15-24-12 Hor.

17.70 24.66 253.0 l257.25 Y

.75" l-313

=

15-24-13 Hor.

13.95 24.66 398.75 407.25 Y

.75" 4-308B

=

l

.75"

't

'4-la Hor.

13.95 2 6. f' 5 548.75 557.25 Y

4-308A

=

l Operator Date FOR'. = MS 2C5 2lE0

DOCUMENT NO.

80A4437 my PAGE 17 OF 39 NUCLEAR ENERGY SERVICES. INC.

SCAM SEQUENCE SHEET Track (

Plant / Unit LILCO 24 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Prinary Secondary Seconcary Scanner Sled Pos. Re f y "

Pos. Ref X' Pos. Ref Y" Pos. Ref X' Mode l' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop UP 40" 2

622.19 24.66 230.93 38.92

[lk Scan Sled Scan X' Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

16-24-15 Hor.

21.75 15.25 597.94 618.0 Y

.75" 1-308A l_

[lk 16-24-16

' Vert.

28.0 32.0 597.94 618.0 X

.36 1-308A

=

l I

Operator Date FCW :NES 205 2/50

I DOCUMENT NO.

80A4437 1

any i

PAGE 19 OF 39 NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 0

Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Tcp of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary Secondary Seconaary Scanner Sled Pos. Ref Y" Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Top Stop ArTa Retracted Bottom Arm Extended gggp TNV l 40" 3

597.80 352.87 358.31 7.13 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y AMT Weld Dir.

[lk 18-0-3 Vert.

358.0 2.0 392.5 563.5 x

.36 1-308D

=

4-308A

_1_

[lk 4-308B 18-0-4 Hor.

354.75 5.25 392. 5 h 563.5 Y

.75" l-308D j_

/l\\

4-308A

=

4_,non I

Operator Date FORM : NES 2C5 2/80

DOCUMENT NO.

80A4437 any PAGE 1

OF 39 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 0

Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. 91ock No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary

.3econdary Seconcary SC3""*f Sled Pos. Ref Y" Pos. Ref X' Pos. Ref Y" Pos. Ref X*

Mode l' Arm Posn Top Stop Arm Retracted Bottom Am Extended Stop T 'N 40" 4

597.80 0.66 358.31 14.92 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y AMT Weld Dir.

/1\\

19-0-5 Hor.

5.25 13.95 398.75 407.25 Y

.75" 4-308B l

=

19-0-6 Hor.

5.25 13.95 549.75 557.25 Y

.75" 4-308A Mk

=

o 14-0-7 Vert.

2.0 13.95 392.5 413.5 X

.36 4-308B 1

19-0-8 vert.

2.0

'13.95 542.5 563.5 x

.36 4-308A

_L Operator Date FORM = NES 2C5 2/80

DOCUMENT NO.

80A4437 OE 39 NUCLEAR ENERGY S5 RVICES, INC.

SCAN SEQUENCE SHEET

(

)

v Track (

Plant / Unit LILCO 0

94 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst._ Automated From Too of Vessel Cal. Block No.

SNPS-7 1/4 PDV OD Exam Positional Reference Primary Primary Secondary Seconaary Scanner Sled Pos. Ref Y "

Pos. Ref X' Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Bottom Stop Arm Retracted Arm Extended Top Stop T tJV 40" 4

204.31 24.66 597.94 38.92 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

Vert.

?4.66 35.52 2Al" 254.25

X

.360 1-313

_1

/1\\

2n-24-1 l

20-24-2 Hor.

24.A6 35.52 249.0 253.0 Y

.75" 1 713

=

p G

I I

l l

Operator Date FCRM:NES 205 2/63

DOCUMENT NO.

80A4437 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track (

24 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-7 1/4 RPV OD Exam Positional Reference Primary i rimary Secondary oeco naery Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Bottom Stop Arm Retracted Arm Extended Mode

' Arm Posn Top Stop TNV 40" 6

204.31 28.21 597.94 13.95 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

To X/Y l

Weld lDir.

No.

ATT From To From AMT 21-24-3 Hor.

17.70 24.66 248.0 253.0 Y

.75" 1-313

=

1-307A 1.

21-24-4 Hor.

17.70 24.25 227.0 248.0 Y

.75" l-307A

.l_

21-24-5 Vort.

15.5

?O.5 227.0 241.0

.36 1-3n7A U

=

21-24-6 Vert.

17.70 24.66 241.0 254.25 X

.36 1-313

_I_

l-307A

=

21-24-7 Vert 15.5 17.70 241.0 253.0 X

.36 1-307A

=

l Operator Date FORT.1: NES 205 2 ISO

DOCUMENT NO.

80A4437 0"

OF M

NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track (

24 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-7 1/4 RPV OD Exam Positional Reference Primary Primary Secondary Seconodry 3 ca m,.

Sled Pos. Re f Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X' Bottom Stop Arm Retracted Arm Extended Mode

' Arm Posn Top Stop 7"u an" 2

204.31 23.34 597.94 9.08 Scan Sled Scan X Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

22-24-A Hor.

11.75 17.70 227.0 253.0 Y

.75" l-307A

_L

,=a 1

1 1

1 Operator Date FORM :NES 2^5 2 50

DOCUMENT R!O.

80A4437 OF M NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track (

157 Cal. Data Pkg. No.

,Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Co:r, byst.

Automated From Top of Vessel Cal. Block No.

SNPS-7 1/4 RPV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Bottom Stop Arm Retracted Arm Extended Top Stop m'

4n" 7

7?A.33 1 ; -),7o e,o7,oa 3 g 7, nq Scan Sled Scan X" Scan Y" Index Coverage For Remarks l

To X/Y l

AMT Weld Dir.

No.

/TT From To From 23-157-1 Vert.

152.79 165.64 241.0 254.25 X

.36 1-313 1

23-157-2 Hor.

152.79 165.64 248.0 253.0 Y

.75" 1-313

=

e Operatol Date FCW :NES 205 2/SO

1 DOCUMEMT NO. _80A4437 OF M

NUCLEAR ENERGY SERVICES, INC.

l

~SCAfl SE,nUEi;CE SHEET Plant / Unit LILCO Track (,

157 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

4 Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-7 1/4 PPV OD Exam Positional Reference Primary Primary Secondary 6econcary Scanner Sled Pos. Re f Y "

Pos. Ref X' Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Bottom Stop Arm Retracted Arm Extended top Stop Ier an" l

??6.11 155.5 597.94 141.24 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

To X/Y l

No.

ATT From To From AMT Weld Dir.

24-157-3 Vert.

141.24 152.74 241.0

'54.25 X

.36 1-313 1

24-157-4 llo r.

141.24 152.79 248.0 l253.0 Y

.75" l-313

=

1-307B 1

9 Operator Date FCRM = NES 205 2/30

DOCUMENT NO.

80A4437 m

aw PAGE 25 OF 29 NUCLEAR ENERGY SERVICES. INC.

SCA: SEQUE!;CE SHEET Plant / Unit LILCO Track (

274 Cal. Data Pkg. 1;o.

0 Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Top of Vessel Cal. Block No.

SNPS-7 1/4 PSV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y" Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

l' Arm Posn Bottom Stop Arm Retracted Top Stop Arm Extended Mode TW 40" 7

226.27 269.79 I

412.95 284.00 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y l

AMT Weld Dir.

25-274-1 Vert.

269.79 283.93 241.0 254.25 X

.36 1-313 1

?5-27'-2 Hor.

269.79 283.93 248.0 253.0 Y

.75" 3-313

=

l l

l Operator Data FCRM :NES 205 2/80

DOCUMENT NO.

80A4437 my my F

PAGE 26 op 39

~

NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 274 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Corrp/Sys t.

Automated From Top of Vessel Cal. Block No.

SNPS-7 1/4 FPV OD Exam Positional Reference Primary Primary Secondary Seconoary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode l' Arm Posn Bottom Stop Arm Retracted Arn Extended Top Stop TW 40"

?

??A.?7 771.na 412. M 250.n9 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks Weld lDir.

No.

ATT From To From To X/Y AMT 26-274-3 Vert.

259.08 '269.79 241.0 254.25 x

.360 1-313 1

1-307C

=

26-274-4 Hor.

259.08 269.79 248.0 253.0 Y

.75" l-313

=

1-307C L

I I

1 Operator Date FORM = NES 205 2:20

DOCUMENT NO.

8CA4437 1 " "' ","' NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUE!;CE SHEET O

Plant / Unit LILCO Track (

22 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.-

Comp /Syst.

Automated From Botto.,

of Vessel Cal. Block No.

SNPS-7 1/4 RPV OD Exam Positional Reference Primary Pra. mary Secondary Seconcary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode l' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop TrP 40" 7

146.68 26.21 49.06 11.95 Scan Sled Scan X' Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y AMT

'deld Dir.

27-22-1 Hor.

ll. 'i 5 24.25 104.0 l 140.0 Y

.75" 1-307A L.

~~

27-23-2

/ert.

15.5 20.5 104.0

'140.0 X

.36 1-307A

=

l Operator _

Date FCRt.t :.NES 225 2/20

DOCUMENT NO. 80A4437 a

w mer Li 91 PAGE

?P OF 39

" ~

NUCLEAR ENERGY SERVICES, INC.

I SCAN SEQUENCE SHEET v

Track (

Plant / Unit LILCO 0

135 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS-7 1/4 RPV OD Exam Positional Reference Primary Primary Secondary Seconaary gcanner Sled Pos. Ref Y"

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop UP 26b 1

274.6A 136.5 1

49.15 144.29 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

To X/Y l

No.

ATT From To From AMT Weld Dir.

-!15-1 7ert.

136.5 140.5 104.0 241,n X

.36 1-107B

=

28-135-2 Vert.

136.5 141.24 241.0 254.25 X

.36 1-313 1

1-307B

=

28-135-3 Hor.

136.5 144.25 104.0 248.0 Y

.75" l-307B 1

28-135-4 Hor.

136.5 141.24 248.0 253.0 Y

.75" l-313

=

1-1079 1

s Operator Date FOR'.1:NES 205 2/80

DOCUMENT NO.

80A4437 NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET Trackf Plant / Unit LILCO 135 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

k Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS 7 1n RPV OD Exam Positional Reference Primary Prira r'v Secondary deconcary Scanner Sled Pos. Ref Y "

Pos. Ref X' Pos. Ref Y" Pos. Ref X' Mode l' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop UP 26 2

279.68 131.1 49.15 lin.9 Scan Sled Scan X" Scan Y" Index Coverage For Remarks l

l To X/Y l AMT Weld Dir.

No.

ATT From To From 29-135-5 Vert.

135.5 136.5 104.0 241.0 X

.36 1-307B

=

29-135--6 Vert.

131.1 136.5 241.0 254.25 X

.36 1-313

_1_

l-307B

=

l l

I 29-135-7 Hor.

131.75 136.5 104.0 248.0 Y

.75" l-307B 1

l253.0 29-135-R Hor.

131.1 136.5 248.n Y

.75" l-313

=

l-307B

_1_

l Operator Date FORM : NES 205 2/SO

DOCUMENT NO.

80A4437 p

mer 6

PAGE 10 OF 39 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUE?CE SHEET Track ( __ 135 Cal. Data Pkg. No.

Plant / Unit LILCO Shoreham Unit :

Rack Teeth Dir.

N Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS 7 1/4 RPV OD Exam Positional Reference Primary Primary Secondary Seconoary Scanner Sled Pos. Re f Y "

Pos. Ref X' Pos. Ref Y" Pos. Ref X' Mode

' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop UP 2 6 *a 3

279.68 133.5 49.15 125.71 Scan Sled Scan X' Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y l

AMT Weld Dir.30-135 0 Hor.

127.11

]31.1

?48.0

?53.0 y

75" 1-313

.=

.36c l-313

._1_

30-135-10 Vert.

127.11 131.1 241.0 254.25 I

I l

k Operator.

Date FORM :NES 2C5 2/30

DOCUMENT NO.

80A4437 PAGE 31 OF 39 NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUEN2E SHEET Plant / Unit LILCO Track (

255 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

P-Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS-7 1/4 RPV OD Eyam Posit.ional Reference Primary Primary Secondary Seconaary Scanner Sled Pos. Re f Y" Pos. Ref X*

Pos. Ref Y" Pos Ref X*

Mode l' Arm Posn To.o Stop Arm Retracted Arm Extended Bottom Stop UP l 26 1

279.68 256.5 49.15 264.29 Scan Sled Scan X' Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

31-255-1 Hor.

256.5 264.25 104.0 248.0 Y

.75" 1-307C 1

31-255-2 Hor.

256.5 259.08 248.0 253.0 Y

.75" 1-313

=

1-307C 1

1 31-255-3 Vert.

256.5 260.5 104.0 241.0 X

.36 1-307C 0

=

31-255-4 vert.

256.5 259.08 241.0 254.25 X

.36 1-313 1

1-307C

=

3 Operator Date FCRM:NES 2C5 220

DOCUMENT' NO.

80A4437

{

"' --~~

NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 255 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS-7 1/4 PSV OD Fxam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y "

Pos. Ref X' Pos. Ref Y" Pos. Ref X' Mode l Arm Posn Top Stop Arm Retracted Bottc.m Stop Arm Extended DP

?6L 2

274 6A

?;1.1 44.14 25R.o Scan Sled Scan X' Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

32-255-5 Hor.

251.75 256.5 104.0 248.0 Y

.75" 1-307C

_j_

32-255-6 Hor.

251.1 256.5 248.0 253.0 Y

.75" 1-313

=

l-307C 1

l

~

32-255-7

'/e rt.

255.5 256.5 104.0 241.0 X

.36 1-30 7ef 0

=

~

32-255-8 Jert.

251.1 256.5 241.0 254.25_

X 3 e-O 7-313

' _.1._

1-307C

=

i s

Operator Dace-FCP.M :NES 205 2/80

DOCUMENT NO.

80A4437 sur PAGE 33 op 39 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 255 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS 7 1/4 RPV OD Exam Positional Reference Primary Primary Secondary 6econcary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X, Top Stop Am Retracted Arm Extended A, ode

. Am Posn Bottom Stoo-UP 26 3

279.68 253.5 49.15 245.71 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

33-255-9 Vert.

245.71 251.!

241.0 254.25 X

.36 1-313 1

33-255-10 Hor.

245.71 251.1 248.0 253.0 Y

.75" 1-313

=

l Operator Date FORM :NES 205 2/S0

s DOCUMENT NO.

80A4437 my aar iJ

~

PAGE la OF 19 NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Plant / Unit LILCO Track-d _ 255 Cal. Data Pkg. No.

Shoreham Unit I Rack Tieth Dir.

k Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Prom Bcttom of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Pr rary Secondary beconcary Scanner Slad Pos. Re f y "

Pos. Ref X' Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Top Stop Arm Retracted Bottom Stop Arm Extended 26 1

279.68 256.5 49.15 264.29 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks l

No.

ATT From To From To X/Y AMT Weld Dir.

l

.36 1-313 1

34-255 1 Vert.

256.5 263.95 251.75 263.5 X

34-255-2 Hor.

256.5 263.95 253.0

257.25 Y

.75" 1-313

=

G I

l l

1 l

I Operater Date FORM :NES 2C5 2MO

DOCUMENT NO.

80A4437 my PAGE 35 OF 39 f UCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SHEET Track (

Plant / Unit LILCO 255 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS-6

,RPV OD Exam Positional Reference Primary Pr1I arY Secondary

.Seconoary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X' Mode

'A m Posn Top Stop Am Retracted Arm Extended Bottom Stop Up

?6b 2

279.68 251.1 49.15 258.9 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks f

To X/Y l

No.

ATT From To From AMT Weld Dir.

35-255-3 Hor.

251.1 256.5 253.0 257.25 Y

.75" 1-313

=

l 35-255-4 Vert.

251.1

'256.5 251.75'263.5 X

.36' l-313 1

I l

e Operatcr Date FORM : NES 2R2/SO

DOCUMENTWO.

80A4437 l

I.

PAGE 16 OF 39 NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET l

IPlant / Unit LILCO Track (

255 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From p c + c-of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X" Mode l' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop "D

2AL 3

?70,AA

?;?.;

4o,15 745.71 Scan Sled Scan X*

Scan Y" Index Coverage For Remarks Froml To X/Y AMT Weld lDir.

No.

ATT From To 36-255-5

'/e r t.

245.71 251.1 251.75 l 263.5 X

.36 1-313

_j_

36-255-6 Hor.

245.71 251.1 253.0 257.25 Y

.75" l-312

=

l I

I Operator Date FCRM :NES 2C5 2/80

DOCUMENT NO. 80A4437 p

ammr Z

~

PAGE 37 op 39 NUCLEAR ENERGY SERVICES. INC.

SCAN SEQUENCE SHEET G

l Track (

Plant / Unit LILCO 135 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

k Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference mU rimaU Secondag Secoman Scanne*.

Sled Po s. Re f y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode

' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop I

?AL 1

?74.AP 176.5 40.15 144.29 "P

Scan Sled Scan X*

Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y AMT.

Weld Dir.

37-135-1 Vert.

136.5 141.24 251.75 263.5 X

.36 1-313 1

37-135-2 Hor.

136.5 141.24 253.0 257.25 Y

.75" 1-313

=

I I

Operator Date FCR'.i:NES 205 2/50

DOCUMENT NO. 80A4437

~

NUCLEAR ENERGY SERVICES, INC.

SCAN SEQUENCE SIIEET O

Track (

Plant / Unit LILCO 135 Cal. Data Pkg. No.

Shoreham Unit I Rack Teeth Dir.

P Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SNPS-6 RPV OD Exam Positional Reference Primary Primary Secondary Seconaary Scanner Sled Pos. Re f y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

.l Mode

' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop nn

?ra

?

? 70, r,s 111,1 ao,1s 1an,o Scan Sled Scan X*

Scan Y" Index Coverage For Remarks Froml To From To X/Y l

AMT Weld Dir.

No.

ATT 38-135-3 lior.

131.1 136.5 253.0 357.25 Y

.75" l-313

=

38-135-4 Vert.

131.1 136.5 251.75 263.5 X

.36" 1-313

,j_

8 l

Operator Date FORM:NES 205 2 30

DOCUMENT NO. 80A4437 PAGE 39 op 39 NUCLEAR ENERGY SERVICES, INC.

l SCAN SEQUENCE SHEET Track (

135 Cal. Data Pkg. No.

Plant / Unit LILCO Shoreham Unit I Rack Teeth Dir.

Proc. No. 80A0480 Rev.

Comp /Syst.

Automated From Bottom of Vessel Cal. Block No.

SN1,S-6 PPV OD Exam Positional Reference Primary Primary Secondary Seconcary Scanner Sled Pos. Ref Y "

Pos. Ref X*

Pos. Ref Y" Pos. Ref X*

Mode l' Arm Posn Top Stop Arm Retracted Arm Extended Bottom Stop em

, c t.

97o.co io, _n ao.ic l o t i, Scan Sled Scan X*

Scan Y" Index Coverage For Remarks No.

ATT From To From To X/Y l

AMT Weld Dir.

39-135-5 Vert.

127.11 131.1 251.75 263.5 X

.36 1-313

_l_

.75" 1-313 34-135-6 Hnr.

127.11 131.1 253.0 257.75 Y

=

~

l Operator Date

(

FORM ~ NES 205 2/50

DOCUMENT NO.

80A4437

)

11 av NUCLEAR ENERGY SERVICES, INC.

=

b:

APPENDIX B WELD SCAN CHECK-OFF SHEETS f.

1 l C t

i

\\

cC=u = ss 2:s 2:50

DOCUMENT NO.

80A4437 Aw c9 Jew 7

L k

PAGE 1

OF 27 NUCLEAR ENERGY SERVICES, INC.

~

WELD SCAN CHECK-OFF SHEET t' ~ ',

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0420 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 1 (

___30 RPV OD Exam Weld No.

1-308/

Exam Coverage l_ Scan Coverage Required Scans From To From To 553.0" 618.0" 24.75c 35.25

/

1 14-24-8 l

16-24-15 l

l l

Remarks:

,_.x i

\\.,

Exa= Coverace

= Scan Coverage Required Scans From To From To 553.0" l

618.0" 28' 32

!4-24-4 16-24-16 Remarks:

O FC '.t :NES 2C5 2/50

DOCUMENT NO.

80A4437 y

y

, ~.

E 2

OF 27 Y

~^ -

NUCLEAR ENERGY SERVICES, INC.

hTLD SCAN CHECK-OFF SHEET

,_s

(

~~'

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Autor.ated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

1-308B 150 Exam Coverage

_l_

Scan Coverage Required Scans From From To 553.0" 618.0" 144.75' 155.25*[1 10-157-8 21_1c7-14

)

Remarks:

Exam Coverace C Scan Coverage Required Scans From To From To h

553.0" 618.0" 148 152 10-157-12 11-157-13 Re: arks :

e FCPY :NES 205 2/60

DOCUMENT NO.

80A4437 d5 Aq

. _ Just r'j 1

~

PAGE 3

OF 27

~~'~

[

NUCLEAR ENERGY SERVICES. INC.

WELD SCAN CHECK-OFF SHEET

,s

/

h s

/

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

1-308C 270 Exam Coverage

_!_ Scan Coverage Required Scans Fm Fm To 553.0" 618.0" 264.75 275.25 /l\\

4-270-1 1

4-270-2 c_

7e_c 5-270-6 6-270-9 Remarks:

't.

Exam Coverace

= Scan Coverace Required Scans From To From To

,!lk 553.0" 618.0" 2f1 272 4-270-4 6-270-8 4-270-3 Remarks:

0 t

FC='.? = NES 205 2130

DOCUMENT NO.

80A4437 A 7..

mar k

NUCLEAR ENERGY SERVICES, INC.

PAGE 4

OF 27 WELD SCAN CHECK-OFF SHEET

,m

(

'~'

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 (O

RPV OD Exam Weld No.

1-308D Exam Coverage

} Scan Coverage Required Scans From To From To h

403" 553" 354.75*

5.25 h\\

18-0-4 Remarks:

O Exan Covera ce r Scan Coverage Required Scans From To From To

[lk 403" 553" 358 2

18-0-3

[lh Remarks:

e FORM : NES 205 2/20

DOCUMENT NO.

80A4437 y

^

R

[ E' PAGg' 5

OF 27 NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CHECK-OFF SHEET fm i

v Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

1-308E 120 Exam Coverage

_I Scan Coverage Required Scans Fm To Fm To 403.0" 553.0" 114.75' 125.25* 1 1,_,1,_9 Remarks:

Exam Coverace C Scan Coverage Required Scans From To From To 403.0" i

553.0" 118' 122 1

1?-113-3 12-113-4 Remarks:

e FCW :NES 205 2/60

DOCUMENT NO.

80A4437 a m,an a

mer c

e i.,

PAGE 6

op 27

" ' ' ~

NUCLEAR ENERGY SERVICES. INC.

ex WELD SCAN CIECK-OFF SHEET f

Plant / Unit LILco Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst. Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

1-308F 240 Exam Coverage l_ Scan Coverage Required Scans From To From To

[1\\

403.0" 553.0" 234.75*

245.25 8-247-8 l

1 i

Remarks:

G Exam Coverace

= Scan Coverage Required Scans From To From To

[1\\

403.0" 553.0" 238*

242' R-?47-6 8-247-5 L(1h Rema rks :

e FORY:NES 2 5 2/80

DOCUMENT NO.

80A4437 J,

my mer

_1,_-

t e

n PAGE 7

OF 27 l

NUCLEAR ENERGY SEPVICES, INC.

x WELD SCAN CHECK-OFF SHEET

/\\sj Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV CD Exam Weld No.

1-308G 30 Exam Coverage L Scan Coverage Reouired Scans From To From To 253.0" 403.0" 24.75*

35.25'/h 14-24-5 14-24-6 14-24-7 Remarks:

.f s

_/

Exam Coverace C Scan Coverage Required Scans From To From To

[1\\

253.0" 403.0" 28 32 14-24-1 14-24-2 14-24-3 Remarks:

FOR'.i:NES 205 2/80

DOCUMENT NO. 80A4437 i:

7.1 ssi L'

W PAGE 8

OF 27

" " ' - ~ -

NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CHECK-OFF SHEET

'w -

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block Nc,.

SNPS-6 RPV OD Exam Weld No.

1-308H 150 Exam Coverage

.l Scan Coverage Required Scans Fm From To 155.25* b 253.0" 4n1.n" 144.75*

10-157-5 10-157-6 9

emarks:

R Exam Coverage 2 Scan Coverage Required Scans From To From To 253.0" 403.0" 148 152

'1\\

l 10-157-9 10-157-10 10-157-11 Remarks:

e FORM :: NES 205 2/50

DOCUMENT NO.

80A4437 J q JE 9 AREF 5

PAGE 9

OF 27 NUCLEAR ENERGY SERVICES. INC.

WELD SCAN CHECK-OFF SHEET

,_s

('"

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

1-308J 270 Exam Coverage

_I_

Scan Coverage Reg. ired Scans From To From To 275. 25 /_l_

253.0" 403.0" 264.75 2-274-3 2-274-4 3-274-8 1-274-9 3-274-10 Remarks:

Exam Coverace z Scan Coverace Required Scans From To From To 253.0" 403.0" 268 272 h

?-774 1 2-274-2 3-274-6

/i\\

3-274-s b\\

3-274-7 Remarks:

e FOR'.1 NES 205 2/S0

DOCUMENT NO.

80A4437 e., ee mar a

.a

.l N hl. ~ ~

PAGE 10 OF 27 NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CHECK-OFF SHEET O

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A04SO Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 (f 553 RPV OD Exam Weld No. 4-308A Exam Coverage L Scan Coverage Required Scans l

i FI ma To 340.03*

26.65 542.5" 563.5" /l'\\

1-347-1 1-347-4 15-24-11 18-0-3 19-0-8 Remarks:

e Exam Coverage

= Scan Coverage Required Scans From To From To 340.03 26.65 548.75" 557.25"/l\\

1 747-2 1-u7 7 15-24-14 18-0-4 1

19-0-6 l

Rera rks :

l I

FC=M = NES 2C5 2iE0

l DOCUMEN T ECO.

80A4437

^

NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CEECK-OFF SHEET Plant / Unit LILCO p

Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

4-308A 553" Exam Coverage

_l Scan Coverage Required Scane F

From To ins.41o 11s.37o 5a2.5" 563.5" d\\

13-113-8 Remarks:

C Exam Coverace C Scan Coverage Required Scans From To From To 106.41 115.37 548.75" 557.25" y 13-113-6 Remarks:

8 FOR'.1:NES 205 2/83

DOCUMENT NO. 80A4437 A

m1 mar PAGE 12 OF 27 NUCLEAR ENERGY SERVICES. INC.

WELD SCAN CHECK-OFF SHEET O

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV 00 Exam Weld No. 4-308A 553" Exam Coverage L Scan Coverage Required Scans From To From To 245.40 278.02*

542.5" 563.5" /l\\

4-270-3 c 97n-7 7-247-2 Remarks:

Exam Coverace C Scan Coverage Required Scans From To From To 245.40 278.02 548.75" 557.25"[1\\

4-?70-1 5-270-5 7 9z7-z Rc vks:

0 FORM :NES 205 2:50

DOCUMENT NO.

80A4437 A p an aw j

5 i

PAGE 13 op 27 NUCLEAR ENERGY SERVICES, INC.

WELD SCTN CHECK-OFF SHEET e

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst. Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

4-308B 403" Exam Coverage

_l_ Scan Coverage Required Scans From To From To 359.95 35.53 392.5" 413.5"[lh 14-24-3 l

15-24-10 19-0-7 18-0-3 Remarks:

0 Exam Coverace 2 Scan Coverace Required Scans From To From To 407.25"h 359.95 35.52 398.75" 14-24-7 15-24-13 29-0-4 19-0-5 Remarks:

I FCOM NES 2C5 2/30

DOCUMEMT NO' 80A4437

^? "

O NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CHECK-OFF SHEET O

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No. 4-3083 403" Required Scans Exam Coverage L Scan Coverage From To From To 106.41 124.24 392.5" 413.5"/1\\

1?-117-7 13-113-7 Remarks:

O Exam Coverace

= Scan Coverage Required Scans From To From To 106.41 124.24 398.75" 407.25" /l\\

19-117-1 12-113-2 13-113-5 I

Remarks:

G FCRM:NES 2C5 2;50

DOCUMENT NO. 80A4437 JT m1 mar i

r 27 PAGE 15 OF

~

NUCLEAR ENERGY SERVICES, INC.

(N WELD SCAN CHECK-OFF SHEET

(-

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

4-308B 403" Exam Coverage

_l_

Scan Coverage Required Scans From To From To 147.81*

165.64 392.5" 413.5" /Y\\

0-157-4 10-157-11 O

emarks:

R Exam Coverage r Scan Coverage Required Scans From To From To 147.81' 165.64 398.75" 407.25" /l\\

o,1c7_?

10-157-6 10-157-7 Remarks:

O FC:M :NES 205 2/50

DOCUMEf4T NO.

80A4437 a

ee amar

,i F

H' hl PAGE i f, OF 27 NUCLEAR ENERGY SERVICES, INC.

f'"s WELD SCAN CHECK-OFF SHEET

'._-)

Plar.t/ Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst. Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No. 4-308B 403" 4

Exam Coverage

_l Scan Coverage Required Scans Fm Fmm To 413.5" k 236.53 254.36 392.5" 7-247-1 8-247-5 Remarks:

es

(

\\_,/

Exam Coverace C Scan Coverace Required Scans From To From To 236.53 254.36*

398.75" 407.25"/1\\

n, 8-247-7 8-247-8 Remarks:

O FCR.1 = NES 205 2160

DOCUMENT NO.

80A4437 J. A9 mer h

b PAGE 17 OF 27 NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CHECK-CFF SHEET Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS r; RPV OD Exam Weld No. 4_ anan ana Exam Coverage

_L Scan Coverage Required Scans Fm h

Fm To 413.5" h 266.10 283.93*

392.5" 2-274-2 7-774-7 Remarks:

e Exam Coverace r Scan Coverage Required Scans From To From To 266.10 283.93 398.75" 407.25"/1\\

2-274-4 3-274-11

/1h 3-274-10 Remarks:

O FCOM NES 205 2/60

DOCUMENT NO.

80A4437

)

J e em e

muur l

?

I.

PAGE 18 OF 27

~~ -

NUCLEAR ENERGY SERVICES, INC.

~

g g WELD SCAN CHECK-OFF SHEET

^

' __./

\\

Plant / Unit Litco Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

1-313 253" Exam Coverage I Scan Coverage Required Scans Fm 2

Fm To 263.5"[1\\

17.70 251.75" 3 e_

e,o la_,a_1 15-24-9 Remarks:

~..

Exam Coverace 2 Scan Coverage Required Scans From To Prom To 257.25"[1h 17.7n 35.52*

253.0" 14-24-5 15-24-12 Remarks:

0 1

F C:'.i :NES 2C5 2/SO

DOCUMENT NO.

80A4437 mar O, m,

r A

J b

27 PAGE 19 OF d

o NUCLEAR ENERGY SERVICES, INC.

/~~N WELD SCAN CHECK-OFF SHEET t/

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exam Weld No.

1-313 253" Exam Coverage

_L Scan Coverage Required Scans From To From To 127.11' 165.64 251.75" 263.5" d 9-157-3 10-147-9 37-135-1 38-135-4 39-135-5 Remarks:

Exam Coverace

= Scan Coverage Required Scans From To From To 257.25"[1\\

127.11 165.64 253.0" 0-157-1 10-157-5 37-135-2 38-135-3 39-135-6 Remarks:

O FCR'.i :NES2C5 2/SO

DOCUMENT NO.

80A4437 my PAGE 20 OF 27

~ ^ ~ ' " ^ ~

NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CHECK-OFF SHEET Plant / Unit LILCO Shoreham Unit I Proc. No. 80A04SO Rev.

Camp /Syst.

Automated Cal. Block No.

SNPS-6 RPV OD Exa.m Weld No.

1-313 253" Exam Coverage l_ Scan Coverage Required Scans Fm To From To 245.40 283.93 251.75" 263.5" /l\\

?-274-1

'-?7a-5 34-255-1 35-255-4 36-255-5 Remarks:

O Exam Coverace r Scan Coverage Required Scans From To From To 257.25"[lh 245.40 283.93 253.0" 2-274-3 3-274-8 34-255-2 35-255-3 36-255-6 Remarks:

O FORM :NES 2C5 2/50

~

DOCUMENT NO.

80A4437 NUCLEAR ENERGY SERVICES. INC.

PAGE 21 OF WELD SCAN CHECK-OFF SHEET V

Plant / Unit LILCO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-RPV OD Exam Weld No.

1-307A 18*

Exam Coverage

_L Scan Coverage Required Scans From To From To 104.0" 140.0" 11.75' 24.25' 27-2?-1 l

Remarks:

l Exam Coverace C Scan Coverace Required Scans From To From To 104.0" 140.0" 15.5e 120.5 27-22-2 I

Remarks:

l I

FORM :NES 2C5 2/80

DOCUMENT WO. 80A4437 J 9 mr9 e

mEr

'a D

R PAGE 22 or 27 d

- - ' ^ -

NUCLEAR ENERGY SERVICES. INC.

WELD SCAN CHECK-OFF SHEET Plt.nt/ Unit LIICO Shoreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SNPS-7 1/4 RPV OD Exam Weld No.

1-307A 18 Exa. n Coverage

_l Scan Coverage Required Scans From To From To t

227.0" 253.0" 11.75 24.25*/lk 21-24-3 21-24-4 I

22-24-8 b\\

+-

Remarks:,

Exam Coverace

= Scan Coverage l

L Fror Required Scans To From To f

[1\\

227.0" 253.0" 15.5 20.5 21-24-5 21-24-6 21-24-7 p

1 l

Remarks:

O l

FORM :N3S 2;b 2/80

DOCUMENT NO.

80A4437 a,.<se e

mar u

c4 r'

M 6

PAGE 23 op 27

" ~ ' ' ' '

NUCLEAR ENERGY SERVICES. INC.

(' ~.

WELD SCA!; CHECK-GFF SHEET Q_J Plant / Unit LILCO Shoreham Unit I P:cc. 13o. 80A0 A.80 Rev.

Comp /Syst.

Automated Cal. Block tio.

S!3PS-7 1/4 1-307B,(138' RPV OD Exam Weld t;o.

Exam Coverage

_L Scan Coverage Required Scans From To From To 144.25*[1\\

104" 253.0" 131.75

'1-197-4 2 R-13 5-3 28-135-4 29-135-7 29-135-8 g,-

Remarks:

'v Exam Coverace

= Scan Coverage Requircd Scans From To From To 104" 253.0" 135.5*

140.5*/l\\

28-135-1 2R-135-2

?o-135-5 29-135-6 Remarks:

O FCR.t : NES 2C5 2/S0

DOCUMENT NO. 80A4437 ag mq my rg r,

GE 24 op 27 NUCLEAR ENERGY SERVICES, INC.

WELD SCAN CHECK-OFF SHEET Plant / Unit LILCO Shoreham U?.it I Proc. No. 80A0480 Rev.

Corp /Syst.

Automated Cal. Block No.

SMPS-1 1n RPV OD Exam Weld No.

1 307c 2 3o Exam Coverage

_l_

Scan Coverage Required Scan From To From To 264.25*[1\\

104" 253.0" 251.75' 26-274-4 31-255-1 31-255-2 32-255-5 32-255-6 e' Recarks:

l Exam Coverace r Scan Coverage Required Scans From To From To 104" 253.0" 255.5 260.5" /lh 26-274-3 31-254-3 31-255-4 l

32-255-7 l

32 255-8 Rcra rks :

l h

FC='A = NES 205 2:80

(

DOCUMENT NO.

80A4437 m9 mur ij PAGE 25 27

~~~ -'

NUCLEAR ENERGY SERVICES, INC.

OF l

WELD SCAN CHECK-OFF SHEET l

Plant / Unit LILCO

\\

l Choreham Unit I Proc. No. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block No.

SUPS-7 l'4 RPV OD Exam Weld No.1-313 253" Exam Coverage

_L Scan Coverage Required Scans From To From To 17.70 35.52*

241" 254.25",/l\\

?n-?a-1 21-24-6 Remarks:

Exam Coverage

= Scan Coverage Required Scans From To From To 17.70 35.52 248" 253" /1\\

,n_,a_,

21-24-3 Remarks:

O FC:f t :NES2:5 2 30

DOCUMENT NO. 80A4437 ag,

3 GE 26 or 27 NUCLEAR ENERGY SERVICES, INC.

9

_ ELD SCAN CHECK-OFF SHEET W

Plant / Unit _

LILCO S_horeham Unit I Proc. No. 80A0480 Rev.

Comp /Syst. Autcmated Cal. Block No.

SNPS-7 1/4 RPV OD Exam Weld No.

1-313 253" Exam Coverage

.1. Scan Coverage Required Scans Fmm From To 254.25"[lh 127.11*

165.64o 241" 23-157-1 9a-1c7-1 99-17;-?

29-135-6 30-135-10 Remarks:

O Exam Coverace

= Scan Coverage Required Scans From To From To

?sa.n" h 197.11 164.64o 248" o,-3ny-?

24-157-4 2 8'- 135 ~ 4 29-135-8 30-135-9 Renarks:

O FOC.M :NES 2C5 2. 30

DOCUMENT WO. 80A4437 aq mar ej NUCLEAR ENERGY SERVICES. INC.

^^ ~

PAG ti 27 OF 27 WELD SCAf CHECK-OFF SHEET 9

Plant / Unit LILCO Shoreham Unit I Proc. I o. 80A0480 Rev.

Comp /Syst.

Automated Cal. Block tio.

SNPS-7 1/4 RPV OD Exam Weld Io.

1-313 253" Exam Coverage

_l. Scan Coverage Required Scans

~

Fm Fm g

254.25"g5[

245.40' 283.93 241"

';-774-1 26-274

~3 31-2c5-4 32-255-8 33-255-9 Remarks:

Exam Coverace C Scan Coverage Required Scans From To From To 245.40*

283.93 248" 253.0"

,r_,

_a_,

'n-77a-a 31-255-2 32-255-6 33-255-10 Remarks:

O

\\

l FC=?.* = %ES 2 5 2:E3