e e

LONG ISLAND LIGHTING COM PANY AdC,Tw#Ed"O er.msner SHOREHAM NUCLEAR POWER STATION P.O. BOX 618. NORTH COUNTRY ROAD e WADING RIVER, N.Y.11792 May 19, 1982 SNRC-706 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation Light Water Reactors, Branch 4 U.

S.

Nuclear Regulatory Commission Washington, DC 20555 Shoreham Nuclear Power Station - Unit 1 Docket No. 50-322

Dear Mr. Denton:

Enclosed, please find ten (10) copies of each of the following revisions to the Preservice Inspection Program.

80A0475, Rev. 6

)

80A0472, Rev.

1, Field Change F-3 80A0482, Rev.

7, Field Change F-2 80A0481, Rev. 6, Field Change F-1 80A4437, Rev. 1 These documents are furnished to comply with LILCO's response No. 1 to NRC request 121.16.

Please acknowledge receipt of the documents by signing and returning tne enclosed document trans-mittal control forms.

Very truly yours, J.

L.

Smith

~

Manager Special Projects Shoreham Nuclear Power Station DRil:sg

/

Enc.

p y

cc:

J.

II i' ins (Site)

All parties 8206010%54 L

. ~.

May 17, 1982 Mr. Harold Denton, Director /Oll-020 Office of Nuclear Reactor Regulation Light Water Reactors, Branch 4 US Nuclear Regulatory Commission Washington, DC 20555 Preservice Inspection Program Plan Transmittal Shoreham Nuclear Power Station - Unit 1 W. O. 44430/48923 As holder of a controlled copy of the PSI Program Plan Manual, you will receive all revisions to the Manual as they are issued.

At-tached you will find instructions for inserting the enclosed docu-ments in the PSI Program Plan Manual.

The instructions vill also serve as a checklist to assure that you have received all the re-quired material.

ENCLOSURE (S):

NES Transmittal Letter 5536-333 80A0475, Rev. 6 80A0472, Rev. 1; FC-3 80A0482, Rev. 7; FC-2 80A0481, Rev. 6; FC-1 Please acknowledge receipt of these documents by signing and dating this transmittal in the space provided below.

Return the completed transmittal form to:

D. R. Haeffner, Staff Assistant Long Island Lighting Company Shoreham Nuclear Power Station P.O.

Box 618, North Country Road Wading River, New York 11792 Attachment & Enclosure cc:

Eng. File /SR2...SHI-397 Signed Date D

i s

L U L:===rnle3

' DOCUMENT TRANSMITTAL CONTROL FORM t

ralCLEAR ENERGY SERVICEJ gjS#a"y"ef,7n"ccjfcur ossio No.

769i (203) 196-5000

,k Date NES Protect No.

Task No.

Vendor / Customer Purchase order No.

<-)

4/19/82 5536 200 I

I SHEET of V

Hr. M. Milligan ASSIGNED TO

. Trn F. -.

Long-15tanu Light & Power Q.

Shoreham Nuclear Power Station ORGANIZATION g3 Wading River, New York 11792 THE ENCLOSED CONTROLLED DOCUMENTS ARE HEREWITH BEING TRANSMIT 1ED FOR YOUR USE.

DOCUMENT NO.

REV.

c$$'s COPY NO.

SUPERCEDED OCCUMENT REMARKS / USAGE 80A0475 6

25 NA 5

" Controlled Copy" 80A0472 1

  • 25 NA

,O'

" Controlled Copy"

  • Fie' d change FC-3 for this proc dure 80A0482 7
  • 25 NA g

" Controlled Copy"

  • F' cid change FC-2 for this procedure 80A0481 6
  • 25 NA ff"

" Controlled Copy"

  • F eld change FC-1 for this procedure iote:*Please place the enclosed A

field changes with your present s

3rocedure for reference purposes.

Thank you..

t l

I KINDLY RE URN A SIGNED COPY OF THIS TRANSMITTAL Daphne Beck TO NUCLEAR ENERGY SERV!CES. ATTENTION OF:

IF TRANSMITTAL FORM is NOT S!GNED AND RETURNED TO NES WITHIN 30 DAYS, YOUR CONTROLLED COPY WILL AUTOMATICALLY BECOME UNCONTROLLED.

1 I HEREBY ACKNOWL EDGE RrSE'PT OF THE ABOVE DOCU"ENTS N'C HAVE DESTROYED CR

. MARKED OBSC E F,sL'd iva REti5G46.

/s e f,,,,

j(

On

_ v w._

ht:e die o

....n m ra DOCUMt?'E HOLDER'S COPY r-

- ~ _ _ _

'J g NUCLEAR ENERGY SHRVICES,INC.

p' NES DIVISION

/i j SwE' TE A ROCK ROAO OAN5UAY. cot.N C6610

, i W (2t3) 748-3531 2-AS-M Date ISI FIELD CD.NGE AUTiiORIZATICN

,,, y../-a Document Title Liou n o />ENETRA hl r EXAM-Document No. Son 0+'7A nev. AJ

/N A T/ ON MCCGDu ME Field Change No. _,fd-3 Originator A [ENNA NEN Description of Field Change: tenomon of NOTE,:N / TEM 9.A. A 4 6 FO LLoa-s :

NOTE: AH V BL6CO cu r0 F PENETRA N I~

lyM/CH /5 A OCNO/7/ON N07~ A33CC/ATED Gi t T H A mATEk/A L Di3ccNrsNu/ Tf GAN 6E DENorED AS N O N - A fA. 6 -

VA N T*.

TH/3 /S a6aAt t Y /ND ICA T/ t/E of /mPRot'ER f'KOCESS/d&

OR PA'E5EN CC OF /NTENDED CAV/77ES OR DES /GAf COVf/&ukRT/CA),

WH/GH Fu/ic7roN AS.(WC'EP7~ A3 fdA AVE PENE7~AAN7~ A/tD AEstic76 /N 0

THEIR ft?ESENCE.

THE DETEA'M/NA 7~/CM CF 7'H6 Cdud6 CF AW /NDiCA -

1~/o N OA 7~HE EVALLLAT/CN cp YHE StGNiF/CANGE of /ND/CA?~/ON3fADM THE STAND point of a)HETHEA THEY At?E A/dN-RELEVAN 7~ /ND)CATIOMS OR CD^13EQu.EN7~/A L.13LErH /SHE6, JHAt t-13E 77/E DISCAE7~/OH OF 7*H6 TECHN /CAA), AW LIGHTBLEED curcF PENETR AtJT uMiGH Co^tTA* tNS M ARGA CFHEAVY Garco cu r wH ICH mAY /3E. /YlA5k'IAl& AN INDICATION 6HA LL BE DET6RM INED A'S REl CVMNT AN D CONC s D ERED. AEJE'GTA P;LE".

~

j Reason Ior Chang'e:

f: b R dLARu c ATroN 21 Approvals:

4h%

E.(

nA, 5%m

7,;t5 -gg NES

~

em _

LILCO J,/ - 8 2 1

Distribute to all controlled Copy holders of affected' Docu: ent.

3 Note:

A copy of this authoricction shall be attached to the affected document until a subsequent revision incorporates the field change.

4 F.r.

49 autcuatic~ mxsraits nc eco,m

.2

-; w _..

-.m__ _---

ac:

7~

4 O NUCLEAR ENERGY SERVICES, INC.

.e ~ ~ NES DIVISION

/ /!

ESTEP RDCK ROAO 4./

.Y., N35:t hAfdN AS, lScR.

Date ISI FIELD CH.sliGE AUTHORIZATIO!J A

ml

$//0Af0W NOW8&h& DNCQ Doct: ent Title uwi7- / 8E&v/CE /NJ/ECT/cN Document !Jo. [CS///c2 Rev. 7 AA06As9m 1 LAN 0

Field Change t'o.

AC.1 Originator

[$//hN 1gdg Descriotion of Field Change:

cmx$e is ap/saux D, AecGh?m Psky AND SCNEDMLQ $MYoR Pgessa er yEssEt system,.Z30 0.2-/ 2, 096Ed /S llM00GW AcR,

~

ZTEM Nutr/6ERJ 4 6, 9, /2, /4 /f c2/, o?V, AT30,33, AND 36:

c//w&c Paocroa4E NumaER FAoM 80AoWY[HEMorE aLTA4-

,r 2

ScNic Exems".grtoD PKocsbu,e6...) % EGAo#75(AAANUs9t_

1.a u L TAMoum Egm/NA r/o N lADCEDRieE... ) '

j Reascn for Change:

u.YIL,s %Ayl0N OP /*AOPE& /ROCEOMRc~ FCA2., /VANUAL ML TR430A// C. EXAM /^/'47/CN Of Mf ddO//G /YEMS.

-J J

aJ

-f Apprcvals:

/r

[/

J 3

_BE6_

4O Ecs2l T,i%,ascJ S-23 9 ~2_

A----

[ /II d b

c &b 1

aosw us 3 - 2 3 - f,2.

Distribute to all Controlled Ccpy holders of af fected Cocument.

j 110te:

A copy of this authorization shall Le attached to the affected document unti.1 a cuhnoquent revin ien incorpor.at on the fi.Id change.

k4

n. a v i vu nc e.... m.u,sc c, o.w h

,e g NUCLEAR ENERGY SERVICES,INC.

,/, r-NES DIVISION

~

. )l-SHELTER AOCK ROAD

,w DANEURY. CONN. 06810 L J pc3) 718 3581

  1. M#M Y /98c2.

Date l

ISI FIELD CHANGE AUTHORIZATION Document Title utrenSonsc Emin/ wit ridN 0/= Document No. 28/10'/S/

Rev. (o thP/A/ G - WEL D-5 Field Change No.

/:C - l Originator (kein N kcAGE'

'l Description of Field Change:

D C' " ^'G C t rE+1s ag, 3 4, 3 g op sec 7,og g.;

7o-scso :

-y *7, 37, g 7

@ ADO Yo 6.2 $ 6 fcze.o w s :

33, engiggp ysex grnND M O h'C-

/d* #SO *"

\\

3 4.

D.Asidds riost 3rnietMD A/O.

/3~~0**lD " CS 1

3S.

cati M 4 rro^J STakon2D A'C.

s20 ~0 '/'o - 0S 30*.

dftsdHAT/ CM 374AttMRD

}\\f.,Qo/ -C '/d-CJ 1

@ casace irc+, g. i.i ro sco o :

ts ne e,a,as, ion sinoMos cesuxen i" & ' 60 we")h $N * * ' ' '

h gpp

'7,"o CHHN 7* DM PAfs[ / 9 O raffh*A! // dA Of & S.*a M osse roc <

,n-ns.c w r~

sertu co a=

a sra~ w o i4 Sc

.reo 14 a,,.r. 2 r a e i.c iy -e so-cs

/5

  • pto

. Sina.2

/[

o + /. 75 W

  • f. 25

/t*cfD-C5 u

20 40

  • SYY

.2 0 W + 2* O W * /* 5 20 *&f0 'Oa SY

  • }O
  • L E$

Q4

& r 2.0 stae f. 6' J /.p+'c.c5 AD A) To 04hMT ON 066[ 2/, sen dt g J/g p.p,g g 3,.

ns,wr.ca_ sum on-r-

w ip,s.

me s e,.w nacwa

~-oso-cs

. m.

  • e,e y, r
i. s Reason Yor:'gt*;Ss#"h*5n"g*e :

a

'su ofh

.os v, r

i. e c

S

f l

?.

C

/s/CL u b f ADD /7/OA.)M C A L / 8 f /? 7 '/ da d ALOCAG 1

Approvals:

hcl

_WE5 Fo rA 97A m CEC 3/-//fa N -

m-N ] n J S, f K / / rte c.o,0 l

UEg -

/

nwo 3-9-r2 j}c (7 '

f Distribute to all entrolled Copy holders of affected' Document.

i 1

,j Note:

A copy of this authori::ation shall be attached to the affected document until a subsequent revision inccrporates the field change.

.J 13 h.

4= avtcuatio. susta.es.. e, ceu aw

-~

-