Subject:
flRC Region II Emergency Response Due to an administrative error, extraneous material from an early working draf t of Enclosure 1 to our letter dated January 29, 1982, subject as above, was inadvertently substituted for the intended final version.
Please remove Enclosure 1 from the January 29, 1982 letter and insert the corrected Enclosure 1.
Should you have any questions prior to our announced site visit, the Regional contact for this matter is Mr. J. Philip Stohr (404-221-5544).
FOR THE RE - r1AL ADt11tilSTRATOR J. Phi Stohr, Director Divisi of Emergency Preparedness and Operational Support
Enclosure:
as stated cc w/ encl:
M. D. !!cIntosh, Plant fianager J. T. Moore, Project fianager J. E. Smith, Station llanager 6205040
?
Z ESIy
ENCLOSURE 1 NRC FACILITIES /E0VIPMENT NEEDS AT TSC AND EOF GENERAL GUIDANCE (NUREG 0696)
A.
Technical Sucoort Center (TSC) 1.
In the TSC working space, space for five NRC personnel (minimum size of working space provided shall be approximately 75 sq. ft.fperson).
2.
A separate room adequate for at least three persons to be used for private NRC consultations.
3.
The TSC voice comunications equipment shall include:
hotline tele-phone (located in the NRC consultation room) on the NRC emergency notification system (ENS) to the NRC Ooerations Center; dedicated telephone (located in the NRC consultation room) on the NRC health physics network (HPN).
4.
The TSC comunication system shall also include designated telephones (in addition to the ENS and HPfl Telephones) for use by NRC personnel.
The licensee shall provide at least two dial telephone lines for such NRC use when the TSC is activated.
The licensee shall also furnish the onsite access facilities and cables to the NRC for the ENS and HPN Telephones.
5.
Facsimile transmission capability between the TSC, E0F, and the NRC Operations Center shall also be provided.
B.
Emergency Operations Facili ty (E0F) 1.
The E0F working space shall be sized for nine persons from NRC (minimum size of working space provided shall be approximately 75 sq. ft./ person).
2.
The E0F building shall provide separate office space to accomodate at least five NRC personnel during periods that the EOF is activated for emergencies.
3.
The EOF voice communications equipment shall include:
hotline tele-phone (located in the NRC office space) on the NRC emergency notifi-cation system (ENS) to the NRC Operations Center; dedicated telephone (located in the NRC office soace) on the NRC health physics network (HPN).
4.
The E0F comunication system shall also include designated telephones (in addition to the ENS and HPN telephones) for use by NRC personnel.
The licensee shall provide at least three dial telephone lines for such NRC use while the E0F is activated.
The licensee shall also furnish the access facilities and cables to the NRC for the ENS and HP.N telephones.
5.
Facsimile transmission capability between the E0F, TSC, and the f(RC Operations Center shall be provided.