, Page 1 of 5 REY.

March 19,1982 EMERGENCY. PLAN IMPLEMENTING PROCEDURES

-Index-

)

Procedure #

TITLE REVISION DATE EP-AD-1 Plant Emergency Organization B

01-22-82 EP-AD-2 Emergency Class Determination A

10-21-81 EP-AD-3 Unusual Event A

12-21-81 EP-AD-4 Alert A

12-21-81 EP-AD-5 Site Emergency A

12-21-81 A

12-21-81 EP-AD-6 General Emergency 1

EP-AD-7 Notification of Unusual Event B

12-21-81 EP-AD-8 Notification of Alert B

12-21-81 EP-AD-9 Notification of Site Eme'rgency B

12-21-81

~

EP-AD-10 Notification of General Emergency B

12-21-81 4

EP-AD-11 Emergency Radiation Controls A

12-21-81 5P-AD-12 Personnel Assenbly and Accountability A

12-21,

EP-AD-13A Limited Area Evacuation 12-21-81 EP-AD-13B Emergency Assently/ Evacuation 12-21-81 EP-AD-13C Site Evacuation 12-21-81 EP-AD-14 Search and Rescue 12-21-81 EP-AD-15 Recovery Planning 10-21-81 EP-AD-16 Personnel Injury or Vehicle Accidents 12-21-81 EP-AD-17 Communications -

12-21-81 EP-AD-18 Adninistration of Iodine Blocking Agents 12-21-81 EP-ENY-1 Environmental Team Organization A

12-21-81 EP-ENY-2 Site Access Facility (SAF) Activation A

12-21-81

' saseeeeee-s2e++e C7

  • "" ;::;& 3&G CK.'

82 04 3000R

March 19,1982

, - Page 2 of 5 EMERGENCY PLAN IMPLEMENTING PROCEDURES '

i

-Index-(cont'd)

Procedure #

TITLE REVISION DATE EP-ENY-3A Environmental Protection Director Actions and Directions C

02-18-82 EP-ENY-3B Environmental Monitoring Team Actions B

02-18-82 EP-ENV-3C Primary Determination of X/Q 12-21-81 EP-ENY-3D Altern' ate Determination of X/Q 1,2-21-81 EP-ENY-3E Manual Environmental ' Dose Projection B

02-18-82 C'alculations EP-ENY-3F Protective Action Recommendations 12-21'-81 EP-ENY-4A Sample Acquisition, Portable Instrumentation Use A

12-21-81 EP-ENV-4B Sample Acquisition, Air Monitoring Devices A

12-21-81 EP-ENY-4C Sample Acquisition, 5nvironmental Sampling Techniques A

12-21-81 EP-ENV-5A LCS-1 Operation A

12-21-81 EP-ENY-5B MS-3 Operation A

12-21-81 EP-ENY-SC SN4 II Operation B

01-22-82 EP-ENY-5D PAC-4G Operation A

12-21-81 EP-ENV-5E Reuter-Stokes Operation 8-19-81 EP-ENY-6 Data Analysis, Dose Projections and Protective Action Recommendations DELETED EP-ENY-6A Relocation of Site Access Facility (Habitabili ty) 12-21-81 l

EP-ENY-6B SAF Environmental Sample Analysis Relocation 12-21-81 l

EP-ENY-7 Site Access Facility Communications 12-21-81 EP-ENY-8 Total Population Dose Estimate 12-21-81 2-b

March 19,1982

'

-Index-(cont' d)

Procedure #

TITLE REVISION.

DATE EP-EOF-1 Corporate Staff Emergency Response Organization C

02-18-82 EP-EOF-2 Emergency Operations Facility (EOF) Activation C

02-18-82 EP-EOF-3 Corporate Response to an Unusual Event C

02-18-82 EP-EOF-4 Corporate Response to an Alert C

02-18-82 EP-EOF-5 Corporate Response to a Site Emergency C

02-18-82 EP-EOF-6 Corporate Response to a General Emergency C

02-18-82 EP-EOF-7 Communications and Documentation C

02-18-82 EP-EOF-8 Relocation of E0F B

02-18-82 EP-EOF-9 Interface with Support Organi'zations B

02-18-82 EP-0P-1 Control Room Emergency Organization 12-21'-81 EP-0P-2 Emergency Activation of Control Room A

2-18-82 EP-0P-3 Control Room Communications 12-21-81 EP-OSF-1 Operational Support Facility (OSF) ONganization A

1-15-82 EP-OSF-2 OSF Activation 12-21-81 EP-0SF-3 Work Requests During an Emergency A

1-15-82 EP-OSF-4 OSF Communicat, ions 12-21-81 EP-RET-1 Radiation Emergency. Team (RET) Organization B

12-21-81 l

EP-RET-2 Inplant RET B

12-21-81.

'Na' ch 19,1982

-[Page 4 of 5 r

EMERGENCY PLAN IMPLEMENTING PROCEDURES

,_s 5 -i

-Index-(cont' d)

REVISION DATE Procedure 8 TITLE EP-RET-2A RP0/RAF Activation A

12-21-81 EP-RET-2B Gaseous Effluent Sample and Analysis B

02-18-82 EP-RET-2C Containment Air Sampling and Analysis A

12-21-81 EP-RET-2D Emergency Radiation Entry, Controls and A

12-21-31 Implementation EP-RET-2E Handli~ng of Injured Personnel 12-21-81 EP-RET-2F Personnel Decontamination A

3-19-82 EP-RET-3 Emergency Chemistry Team B

12-2,1-81 EP-RET-3A Liquid Effluent Sample a~nd Analysis A

12-21-81 EP-RET-3B Post-Accident ReactoreCoolant Interim A

1 2-21-81 Sampling Procedure t

EP-RET-4 Site RET B

12-21-81 EP-RET-4A EOF Radiological Monitoring A

10-21-81

~

EP-RET-4B Radiological Controls at Site Access Facility (SAF) 10-21-81 EP-RET-4C Site Radiological Monitoring 12-21-81

~

EP-RET-5 Plume Projections A

12-21-81 EP~-RET-5A Plume Projections (Backup Method)

A 12-21-81 EP-RET-6 Dose Projection A

17.-21-81 EP-RET-7 RAF/RP0 Communications 12-21-81 EP-RET-8 Contamination ' Control at the TWo Rivers 12-21-81 Community Hospital WWWWWWWWWWWWWWWWWW6 9

~ _ _ _ _ _ _ _ - _. _ _. _. _,..., _, _

, Page 5 of 5 March 19,1982 o

EMERGENCY. PLAN IMPLEMENT 2NG PROCEDURES

-Index-l

- (cont' d)

)

Procedure #

TITLE REVISION DATE EP-SEC-1 Security Organization 12-21-81

~

EP-SEC-2 Security Force Response to Emergencies A

12-21-81 EP-SEC-2(a)

Manual Activation of Emergency Sirens 1-29-82 EP-SEC-3 Personnel Accountability (Initial and Maintaining) A 12-21-81 EP-SEC-4 Dosimetry Issue at SAF 12-21-81 EP-TSC-1 Technical Support Center (TSC) Organi.zation 12-21-81 EP-TSC-2 TSC Activation A

02-18-82 EP-TSC-3 Plant Status Procedure A

02-18-82 EP-TSC-4 Emergency Design Change, Major Equipment Repair 12-21-81' EP-TSC-5 TSC Communications 12-21-81 e

t

j

',. WISCONSIN PUBLIC, SERVICE CORPORATION

.l NO.

EP-RET-2F REY. A I

Kewaune? Nuclear Power Plant i TITLE: Personnel Decontamination l

EMERGENCY PLAN IMPLEMENTING PROCEDURE 1

I l'

DATEMAR 191982 l PAGE 1 of 4 I

I i

,[

,[

REVIEWED BY

/M" APPROVED BY

/

l 1.0 APPLICABILITY This procedure shall be implemented by the In-Plant and Site Radiation Emergency Teams (RET) whenever contamination of hands, general body, hair, mouth, or nostrils l

is encountered as indicated by an alirm on ther personnel frisker or mouth or l

nasal swabs above background levels.

2.0 PRECAUTIONS l

2.1 The personnel frisker alarm should be set at 100 cpm above background.

2.2 Personnel decontamination, other than minor hand contamination, will be carried out oo.y under the direction of a Radiation Technologist.

2.3 In no case shall personnel with moutih or nasal contamination be permitted to eat, drink, or smoke, until approved by the Radiological Protection Diiector. The medical consultant will be contacted for all mouth or eye contamination problems.

  • e

3.0 REFERENCES

None 4.0 INSTRUCTIONS 4.1 Minor Hand Contamination l

4.1.1 Instruct the contaminated person to wash for not less than 2 minutes, l

nor more than three minutes with Decon Hand Soap in tepid water.

Give special attention to areas between the fingers and around the i

finger nails.

4.1.2 Re-s,urvey the contaminated area and repeat 4.1.1 as necessary, taking care not to break' the skin or spread contamination. Do not exceed N

three or four. times.

4.2 Heavily Contaminated Hands NOTE: This method should be used only if Step 4.1 has been unsuccessful.

4.2.1 Scrub the. hands with a soft brush using a heavy lather and tepid water.

Instruct the contaminated person to wash for not more than 2 minutes each time. Thorough rinses shall be done between scrubs.

4.2.2 Do not exceed three scrubs and take care not to abrade the skin.

Re-survey for further evaluation after each scrub. Apply lanolin or hand cream to prevent chapping.

I

~ WI5CONSIN PUBLIC SERVICE CORPORATION

' NO.

EP-RET-2F l

~

Kewaunee Nuclear Power Plant l TITLE: Personnel Decontamination EMERGENCY PLAN IMPLEMENTING PROCEDURE I

1 1.

PAGE 2 of 4 DAT[dAR 1 9 1982 i

4.3 Titanium Dioxide 4.3.1 This method shall only be used with approval of the Radiological Protection Director (RPD).

4.3.2 Apply a liberal portion of titanium dioxide, a mild abrasive, in a water paste to the hands. Work this paste over contaminated area for at least 2 minutes. Use water sparingly to keep paste moist.

Rinse with tepid water and follow by washing thoroughly with soap, brush, and water. Be sure no paste is allowed to remain around the nail s.

Re-survey and repeat as necessary.

4.4 Potassium Permanganate 4.4.1 This method shall only be used with approval of the Radiological Protection Director.

4.4.2 Mix equal volumes of a saturated solution of potassium permanganate (6.4gKMn04 to 100 ml water) and 0.2N sulfuric acid. Pour this over the wet hands rubbing the entire surface and using a soft hand brush for not more than two minutes.

(NOTE: This application will remove a layer of skin it allowed to remain in contact with the hands too long; consequently, the times stated here should not be exceeded for any single application). Rinse with tepid water.

4.4.3 Apply a fresh Si, (5gNaHS03 to 100 ml water) solution of sodium acid sulfite (NaHS0 ) in the same manner as described above, using a hand 3

brush and tepid water for not more than two minutes.

(NOTE:

This will remove the permanganate stain and skin layer if in contact with skin more than two minutes.)

Rinse thoroughly and wash with soap and water.

1 4.4.4 Th.is pr,ocedure may be repeated several times, as long as the permanganate solution is not applied for more than two minutes during one washing.

l 4.4.5 Applications to other parts of the body may be facilitated, by the use of swabs or pads dipped in the solutions.

(Use gloves when handling swabs or pads.) Lanolin or hand cream should be applied after washing. DO NOT use near face or other body openings.

4.5 General Body Contamination 4.5.1 Instruct the contaminated person to shower in the " hot sh.ower" room.

Scrub contaminated parts of body with decon soap starting at the neck and working toward the lower extremities. Local areas of contamination will be dealt with as described in Section 3.3 and 3.4 above.

4.5.2 Save all towels, wash rags, etc., so they can be checked for contamination.

O

l a

- WISCONSIll PUBLIC SERVICE CORPORATIO!!

l NO.

EP-RET-2F I

K;waunce fluclear Power Plant l TITLE: Parsonnel Decontamination I

EMERGENCY PLAN IMPLEMEllTING PROCEDURE I

I l'

DATEMAR 191982 l PAGE 3 of 4 I

I 4.6 Hair Contamination 4.6.1 Instruct the contaminated person to wash hair in a sink with shampoo.

Do not use the shower for hair decontamination, as contamination can be spread to the rest of the body.

4.6.2 Check face and neck, as well as hair, for contamination.

Repeat as required.

4.7 Mouth Contamination 4.7.1 Flush

  • the mouth with tap water. Ass'ume a-bent position to prevent swallowing the water.

Do not allow the person to " gargle" the water.

4.7.2 Check the face, nasal areas, and throat for contamination.

4.7.3 Whole body count the ' individual to insure contamination is removed and has not spread to the G-1 tract.

4.7.4. Cases of persistent contamination should be referred' to a physician trained in radiological emergencies.

4.8 Nasal Contamination 4.8.1 Instruct the person to blow his. nose repeatedly.

Save the tissues for counting.

4.8.2 Dampen swab (one for each nostril'), insert carefully as far as possible, and then withdraw swab, twirling it inside of the nostril as it is withdrawn.

Repeat until the swab shows no detectable activity.

l Run a swab on the GeLi for isotope identification.

4.8.3 Cases of persistent contamination should be referred to a physician trained in radiological emergencies.

4.9 Eye Contamination 4.9.1 Irrigate eyes with Aliclear eye lotion (sterile, isotonic solution) l only. Assume a bent position to preclude contamination spread.

4.9.2 After contamination is no longer detected on the frisker or contamination persists, perform a stationary whole body count of the head area.

4.9.3 Cases of persistent. contamination should be referred to a physician trained in radiological emergencies, j

4.10 Persistent Extremity Contamination 4.10.1 Place the bare hand or foot in a rubber or plastic glove or booty.

Tape all openings shut.

l

.-w

._y

T l

7 c

~

11SCONSIN PUBLIC SERVICE CORPORATION l NO.

EP-RET-2F Kewaunee Nuclear Power Plant l TITLE: Pcrsonnel Decontamination I

~

EMERGENCY PLAN IMPLEMENTING PROCEDURE l-l I

DAT51AR 191982 l PAGE 4 of 4 I

I 4.10.2 Place near source of heat for 10 to 15 minutes or until the extremity is sweating profusely. Gloves can be worn for a few hours to utilize body heat.

4.10.3 As soon as the extremity is swea' ting profusely, remove covering and wash with soap and water immediately.

Any delay will allow contamination to seep into the skin pores.

h I

4 4

e

.