ML20052A407
| ML20052A407 | |
| Person / Time | |
|---|---|
| Site: | Robinson |
| Issue date: | 04/13/1982 |
| From: | Herdt A, Julian C NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | |
| References | |
| PNO-II-82-036A, PNO-II-82-36A, NUDOCS 8204280306 | |
| Download: ML20052A407 (1) | |
Text
__
April 13,1982 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE PN0-II-82-36A This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verifi-cation or evaluation, and is basically all that is known by IE staff on this date.
FACILITY: Carolina Power and Light Company Licensee Emergency Classification:
H. B. Robinson Unit 2 Notification of Unusual Event Docket No. 50-261 Alert Hartsville, South Carolina Site Area Emergency General Emergency gg
- f f X Not Applicable V
4 cp I
SUBJECT:
hEACTOR VESSEL IN-SERVICE TESTING INDICATIONS
. h ) _\\
/ '&,Q{ *r 9
Y
~2
[
This PN updates PNO-II-82-36, dated April 12, 1982.
Carolina Power & Light is continuing to investigate indications of two jbleN g
irregularities near or on the outside surface of the pressure vessel.
9 9 un Ultrasonic testing data is being analyzed by Westinghouse Corporation, the nuclear l
steam system supplier, which also performed the pressure vessel inspection.
In order to obtain other relevant data, the licensee is dealing with Combustion Engineering Inc., manufacturer of the vessel, and Southwest Research Institute, which perfonned the pre-operational base line inspection.
Region II, with NRR assistance, is arranging for consultants to assist in the NRC review of the data.
CP&L will make a presentation to the NRC staff in Washington once all data has been compiled. This presentation is expected to take place in the next two weeks or so. A metallurgist from the Region Il staff is continuing to monitor the licensee's actions at the site. The unit has been shut down since February 27 and is scheduled to return to service in early June.
No media interest has developed.
Neither the licensee nor the NRC plans a press release.
The State of South Carolina has been informed.
This information is current as of 11:30 a.m. on April 13.
Contact:
C. A. Julian, RII 242-5589; A. R. Herdt, RII 242-5535 DISTRIBUTION:
H. St.
FINBB Phillips/W E/W Willste Landow Chairman Palladino EDO NRR IE NMSS OIA Comm. Gilinsky AE0D RES Comm. Bradford PA Air Rights MAIL:
Comm. Ahearne itPA SP INP0 ADtt: Doc. Ngt. Br.
Comm. Roberts ELD NSAC Applicable State ACRS Applicable Resident Site // /#
SECY Regional Offices CA Applicable Utility hM
-L U-USDOT/f1TB/Df1T-122.4 (as appficable) e y
8 2 0 4 2 8 0M'~'
I61 N<f