VERMONT YAMKEE NUCLEAR POWER STATION MONTHLY STATISTICAL REPORT 82-04 FOR THE MONTH OF APRIL 1982 f
k
)
k L
82051703 S'9
OPERATING. DATA REPORT DOCKET NO.
50-271 DATE 820510 COMPLETED BY F.J. Burger TELEPHONE (802) 257-7711 ext. 137 OPERATING STATUS tes
- 1. Unit Name: Vermont Yankee
- 2. R: porting Period:
April 1982
- 3. Licensed Thermal Power (MWt):
1593
- 4. Nr.meplate Rating (Gross MWe):
540
- 5. Design Electrical Rating (Net MWe): 514(OC) 504 (CC)
- 6. Maximum Dependable Capacity (Gross MWe):
535
- 7. Maximum Dependable Capacity (Net MWe):
504
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7)Since Last Report, Give Reasons:
- 9. Power Level to Which Restricted,If Any(Net MWe):
- 10. Reasons For Restrictions, If Any:
This Month Yr-to-Date Cumulative
- 11. Hours In Reporting Period 719.00 2,879.00
- 12. Number Of Hours Reactor Was Critical 699.88 2,792.21 67,870.36
- 13. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
- 14. Hours Generator On-Line 696.70 2,744.88 65,786.07
- 15. Unit Reserve Shutdown Hours 0.00 0.00 0.00
- 16. Gross Thermal Energy Generated (MWH) 1,077,390.00 4,320,211.00 94,235,971.50
- 17. Gross Electrical Energy Generated (MWH) 363,477.00 1,466,409.00 31,338,380.00
- 18. Nat Electrical Energy Generated (MWH) 348,771.00 1,406,429.00 29,722,715.00
- 19. Unit Service Factor 96.90 96.38 78.11
- 20. Unit Availability Factor 96.90 96.38 78.11
- 21. Unit Capacity Factor (Using MDC Net) 96.25 96.93 70.02
- 22. Unit Capacity Factor (Using DER Net) 94.37 95.04 68.66
- 23. Unit Forced Outage Rate 3.10 3.62 6.67
- 24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
None
- 25. If Shut Down At End Of Report Period, Estimated Date of Startup:
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY r
COMMERCIAL OPERATION
io AVERAGE-DAILY UNIT POWER LEVEL 50-271 DOCKET NO.
Vermont Yankee UNIT 820510 DATE COMPLETED BY F. J. Burger TELEPHONE (802) 257-7711. Ext. 137 MONTH April DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)
(MWe-Net) 1.
364 17.
sig 2.
491 18.
s17 f
3.
517 19.
520 4.
516 20.
520 5.
520 21.
519
~
6.
519 22.
520 7.
513 23.
520 8.
514 24.
23 4
519 25, 328 j
9.
519 26.
467 10.
11.
27.
443 504 12.
28.
511 518 519 13.
29.
519 14.
30.
15.
31.
l 519 16.
j INSTRUCTIONS:
On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET No 50-271
~
UNIT NAME Vermont Yankee DATE R?ns10 REPORT MONTH April COMPLETED BY F.
J.
Burger TELEPHONE (802) 257-7711. Ext. 137 i
En H
c^
u Cause & Corrective
!O "c
!O License
@4 En No.
Date e
o eo Action to i
e uo o
euo eport#
'O Z
g o
0 82-07 820411 S
0 B
4 N/A RB CONROD Power reduction for a control rod pattern (Power adjustment and surveillance testing.
Reductic n) 820424 F
22.3 A
3 N/A CH INSTRU Reactor scrammed on low reactor vessel 82-08 g j
level due to a failure in thd feedwater.
control system. An investigation revealed dirt in the air circuit of the "A" feed-water regulator valve pneumatic current-to-pressure converter. This caused an in-correct valve position signal to be initiated.
The converter was replaced.
The preventive maintenance program for this equipment will be reviewed and revised as necessary to prevent recurrence.
1 F: Forced Reason:
Methcd:
Exhibit G-Instructions S: Schedule'd A-Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry Sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Regulatory Restriction 4-Other (Explain)
E-Operator Training & License Examination 5
F-Administrative Exhibit I - Same Source G-Operational Error (Explain)
H-Other (Explain)
DOCKET NO.
50-271 Vermont Yankee UNIT
~
r' 820510 DATE COMPLETED BY F. J. Burger IELEPHONE (802) 257-7711, Ext. 137 SAFETY RELATED MAINTENANCE Page 1 of 2 NATURE OF MALFUNCTION LER OR OUTAGE EQUIPMENT MAINrENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION RWCU Valve V12-16A Corrective N/A Position Indicator Faulty Position Realigned Indicator MR 82-0332 Out of Alignment Indication RWCU Pump P49-1B Corrective N/A Normal Wear Pump / Motor Realigned Coupling MR 82-0358 Coupling Misalignment Service Water Pumps Corrective N/A Normal Wear Packing Leakage Repacked Pumps P71A-D MR 82-0367 MR 82-0386 MR 82-0477 Reactor Vessel Pressure Corrective N/A Sticky Me".er Indicator Adjusted Meter indicator PI 2-3-56B MR 82-0383 Movement Sticks Movement RHR Service Water Preventive N/A N/A N/A Replaced Bushings in Pump P8-lC MR 82-0419 Response to Vendor Lettet 4ain Steam Line Corrective N/A Indicator Out of Indicator Read-Recalibrated ladiation Monitor MR 82-0450 Calibration ing Low, Set
- hannel "C" Point Unaffected
DOCKET NO.30-271 Vermont Yankee UNIT 820510 DATE COMPLETED BY F. J. Burger (802) 257-7711, Ext. 137 TELEPHONS SAFETY RELATED MAINTENANCE Page 2 of 2 NATURE OF MALFUNCTION LER OR OUTAGE EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION prywell Pressure Transmitters Preventive N/A N/A N/A Replaced with Upgraded
'T 16-19-29A & B FH1 82-0452 Instruments LPIS Power Supply Corrective LER Failed Output Replaced Power Supply MR 82-0471 82-08/3L Components Deteriorated IPS "A" Corrective N/A Loose Connection Alarm Condi-Tightened Connection MR 82-0474 tion,0pera-bility Unaffected
<0G Steam Supply Valve Corrective N/A Normal Wear Packing Leak Adjusted Packing
>G-9072 MR 82-0481
'CIS Relay 16A-K8A Preventive N/A Worn Relay Noisy Replaced Components MR 82-0496 Components
& Odoriferous as Necessary
~
DOCKET NO.
50-271 Vermont Yankee UNIT 820510 DATE
"#8"#'
COMPLETED BY TELEPHONE (802) 257-7711, Ext. 137 REPORT MONTH April
SUMMARY
OF OPERATING EXPERIENCES Highlights Vermont Yankee operated at 94.06%of rated thermal power for the month.
Gross electrical generation was 363,477 MWH or 93.61% of design electrical capacity.
Operating Summary The following is a chronological description of plant operations including other pertinent items of interest for the month:
At the beginning of the reporting period the plant was at 55% of rated thermal power. A power ascension was in progress recovering the reactor scram of 820330.
820411 At 0030 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> a power reduction was intiated for control rod pattern adjustment and surveillance testing.
At 0120 hours0.00139 days <br />0.0333 hours <br />1.984127e-4 weeks <br />4.566e-5 months <br /> a return to full power was started.
820424 At 0059 hours6.828704e-4 days <br />0.0164 hours <br />9.755291e-5 weeks <br />2.24495e-5 months <br /> the reactor scrammed (See Unit Shutdowns and Power Reductions).
At 2006 hours0.0232 days <br />0.557 hours <br />0.00332 weeks <br />7.63283e-4 months <br /> the reactor was critical.
At 2315 the turbine was phased onto the grid.
At the end of the reporting period the plant was operating at 99.9% rated thermal power.