LOCAL LEAK RATE TEST REPORT Page 6 IV. Local Leak Rate Test Results

1. Type B Acceptance Description As-Found Re-Test As-Left Criteria Equipment Hatch 0 N/A 0 4500 cc/ min Resilient Seals Fuel Transfer 0 N/A 0 4100 cc/ min Tube Gasket-3B Fuel Transfer 0 N/A 0 (100 cc/ min Tube Gasket-3A LRV-44 and Blind 90 N/A 90 < 100 cc/ min Flange Chemical Cleaning 2 N/A 2 4100 cc/ min Penetration Gaskets 119 Chemical Cleaning 2 N/A 2 4100 cc/ min Penetration Gaskets 120 Total as found Type B Leakage: 94 sccm Total ueasured Type B Leakage: 86 seem Total instrument error Type B Leakage: 6 sccm 8204140224 920408 PDR ADOCK 05000 P

LOCAL LEAK RATE TEST REPORT Page 9 _ ,

IV. LOCAL LEAK RATE TEST RESULTS

2. Type c Penetration Inboard Isolation Valves Outboard Isolation Valves PATil LEAKAGE Acceptance Number designation Leakrate designation Leakrate As Found As Left Criteria Comments Scc />t Scc />t scc />f Scc />t Scc />t 110 SAV-24 >20000 SAV-122 3670 >20000 3670 4 4110 i SAV-23 111 IAV-28 2688 2688 2688 42740 121 LRV-50 1656 LRV-36 2138 2158 2158 410960 125 LRV-49 >20000 LRV-38 2916 >20000 2916 4 10960 LRV-52 113 AIIV-1C 11065 AllV-ID 0 11065 45 42500 357 AllV-1A > 20000 AIIV-1B 43000 >20000 140 42500 430 FSV-262 5320 FSV-261 1600 N/A 5320 4 5480 l 122 LRV-51 12491 LRV-35 720000 >20000 4112 (10960 LRV-47 112 IAV-29 846 846 846 42740 116 LRV-45 2 LRV-46 55 55 55 42740 1

- a i i l l  !

i i i

l  ! ',

I ,

i ,'

s i

! i i  ! '

LOCAL LEAK RATE TEST REPORT Page 10 IV. Local Leak Rate Test Results C. Combined Type B & C Total number of Valves tested - 69 Total number of Valves re-tested - 14 Total number of Valves repaired - 11 Total as found leakage - >126692 SCC /M (Type B & C)

Total as left leakage (Type C) - 80276 SCC /M Combined Type B and C leakage - 84093 SCC /M Note: Error adjusted leakages are based on a maximum instrument calibration accuracy of 5% applied in the conservative direction for the total as found and left valves.

(Except where pressure decay valves were calculated.)

Note: A minimum sensitivity of 2.0 cc/ min has been used for each test.

1. Exceeded assigned action values but were determined to be acceptable because of low overall leakage.
2. SFV-18 was repaired but showed no improvement on leakrate. See Summary, page 17.