LOCAL LEAK RATE TEST REPORT Page 6 IV.
Local Leak Rate Test Results 1.
Type B Acceptance Description As-Found Re-Test As-Left Criteria Equipment Hatch 0
N/A 0
4500 cc/ min Resilient Seals Fuel Transfer 0
N/A 0
4100 cc/ min Tube Gasket-3B Fuel Transfer 0
N/A 0
(100 cc/ min Tube Gasket-3A LRV-44 and Blind 90 N/A 90
< 100 cc/ min Flange Chemical Cleaning 2
N/A 2
4100 cc/ min Penetration Gaskets 119 Chemical Cleaning 2
N/A 2
4100 cc/ min Penetration Gaskets 120 Total as found Type B Leakage: 94 sccm Total ueasured Type B Leakage: 86 seem Total instrument error Type B Leakage: 6 sccm 8204140224 920408 PDR ADOCK 05000 P
LOCAL LEAK RATE TEST REPORT Page 9 IV.
LOCAL LEAK RATE TEST RESULTS 2.
Type c Penetration Inboard Isolation Valves Outboard Isolation Valves PATil LEAKAGE Acceptance Number designation Leakrate designation Leakrate As Found As Left Criteria Comments Scc />t Scc />t scc />f Scc />t Scc />t 110 SAV-24
>20000 SAV-122 3670
>20000 3670 4 4110 SAV-23 i
111 IAV-28 2688 2688 2688 42740 121 LRV-50 1656 LRV-36 2138 2158 2158 410960 125 LRV-49
>20000 LRV-38 2916
>20000 2916 4 10960 LRV-52 113 AIIV-1C 11065 AllV-ID 0
11065 45 42500 357 AllV-1A
> 20000 AIIV-1B 43000
>20000 140 42500 430 FSV-262 5320 FSV-261 1600 N/A 5320 4 5480 l
122 LRV-51 12491 LRV-35 720000
>20000 4112 (10960 LRV-47 112 IAV-29 846 846 846 42740 116 LRV-45 2
LRV-46 55 55 55 42740 1
a i
i l
l i
i l
I i
s i
i i
i
LOCAL LEAK RATE TEST REPORT Page 10 IV.
Local Leak Rate Test Results C.
Combined Type B & C Total number of Valves tested - 69 Total number of Valves re-tested - 14 Total number of Valves repaired - 11 Total as found leakage - >126692 SCC /M (Type B & C)
Total as left leakage (Type C) - 80276 SCC /M Combined Type B and C leakage - 84093 SCC /M Note:
Error adjusted leakages are based on a maximum instrument calibration accuracy of 5% applied in the conservative direction for the total as found and left valves.
(Except where pressure decay valves were calculated.)
Note: A minimum sensitivity of 2.0 cc/ min has been used for each test.
1.
Exceeded assigned action values but were determined to be acceptable because of low overall leakage.
2.
SFV-18 was repaired but showed no improvement on leakrate.
See Summary, page 17.