ML20050K543

From kanterella
Jump to navigation Jump to search
Local Leak Rate Test Rept, Pages 6,9 & 10
ML20050K543
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 04/08/1982
From:
FLORIDA POWER CORP.
To:
Shared Package
ML20050K488 List:
References
NUDOCS 8204140224
Download: ML20050K543 (3)


Text

-

9 t

LOCAL LEAK RATE TEST REPORT Page 6 IV.

Local Leak Rate Test Results 1.

Type B Acceptance Description As-Found Re-Test As-Left Criteria Equipment Hatch 0

N/A 0

4500 cc/ min Resilient Seals Fuel Transfer 0

N/A 0

4100 cc/ min Tube Gasket-3B Fuel Transfer 0

N/A 0

(100 cc/ min Tube Gasket-3A LRV-44 and Blind 90 N/A 90

< 100 cc/ min Flange Chemical Cleaning 2

N/A 2

4100 cc/ min Penetration Gaskets 119 Chemical Cleaning 2

N/A 2

4100 cc/ min Penetration Gaskets 120 Total as found Type B Leakage: 94 sccm Total ueasured Type B Leakage: 86 seem Total instrument error Type B Leakage: 6 sccm 8204140224 920408 PDR ADOCK 05000 P

LOCAL LEAK RATE TEST REPORT Page 9 IV.

LOCAL LEAK RATE TEST RESULTS 2.

Type c Penetration Inboard Isolation Valves Outboard Isolation Valves PATil LEAKAGE Acceptance Number designation Leakrate designation Leakrate As Found As Left Criteria Comments Scc />t Scc />t scc />f Scc />t Scc />t 110 SAV-24

>20000 SAV-122 3670

>20000 3670 4 4110 SAV-23 i

111 IAV-28 2688 2688 2688 42740 121 LRV-50 1656 LRV-36 2138 2158 2158 410960 125 LRV-49

>20000 LRV-38 2916

>20000 2916 4 10960 LRV-52 113 AIIV-1C 11065 AllV-ID 0

11065 45 42500 357 AllV-1A

> 20000 AIIV-1B 43000

>20000 140 42500 430 FSV-262 5320 FSV-261 1600 N/A 5320 4 5480 l

122 LRV-51 12491 LRV-35 720000

>20000 4112 (10960 LRV-47 112 IAV-29 846 846 846 42740 116 LRV-45 2

LRV-46 55 55 55 42740 1

a i

i l

l i

i l

I i

s i

i i

i

LOCAL LEAK RATE TEST REPORT Page 10 IV.

Local Leak Rate Test Results C.

Combined Type B & C Total number of Valves tested - 69 Total number of Valves re-tested - 14 Total number of Valves repaired - 11 Total as found leakage - >126692 SCC /M (Type B & C)

Total as left leakage (Type C) - 80276 SCC /M Combined Type B and C leakage - 84093 SCC /M Note:

Error adjusted leakages are based on a maximum instrument calibration accuracy of 5% applied in the conservative direction for the total as found and left valves.

(Except where pressure decay valves were calculated.)

Note: A minimum sensitivity of 2.0 cc/ min has been used for each test.

1.

Exceeded assigned action values but were determined to be acceptable because of low overall leakage.

2.

SFV-18 was repaired but showed no improvement on leakrate.

See Summary, page 17.