d OPERATING DATA REPC2T
~
DOCKET NO. 50-409 DATE 05-05-81_.
COMPLEMD BY L.S. GOODMAN TELEPil3NE 609 689-2331 OPERATING STATUS Notes X. Unit Name: LA CPOR9F POTITNr, UATrp DFarToo_
- 2. Reporting Period: 0001, 04-01-81 TO 2400. 04-30-81 165
- 3. Licensed Thermal Pc,wer (MWt):
65.3
- 4. Nameplate Rating (Cross MWe):
1 50
- 5. Design ElectricalRating(Net MWe):
48
.u
- 6. Maximum Dependable Capacity (Gross MWe):
- 7. Maximum Dependable Capacity (Net MWe):
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:
- 9. Power Level To Which Restricted.If Any (Net MWe):
- 10. Reasons For Restrictions.If Any:
This Month Yr to-Date Cumulative 719 2879 100,778 i1. Hours in Reporting Period
- 12. Number Of Hours Reactor Was Critical 719 2203.5 66.300.5
- 13. Reactor Reserve Shutdown flours 0
0 478
- 14. Hours Generator On-Line 719 2029.2 61.060.5
- 15. Unit Reserve Shutdown Hours 0
0 79'
- 16. Gross Thermal Energy Generated (MWH) 103.912.8 279.997.5 R 161 8i64.4 80.394 2.511.079
- 17. Gross Electrical Energy Generated (MWH) 30.325 --
- 18. Net Electrical Energy Generated (MWH) 28,476 74.643 2.321.923 100.0 70.5 60.6
- 19. Unit Sersice Factor 100.0 70.5 60.7
- 20. Unit Asailability Factor
- 21. Unit Capacity Factor (Using MDC Net) 82.5 54.0 4R.0 79.2 53.2 46.1
- 22. Unit Capacity Factor (Using DER Net)
- 23. Unit Forced Outage Rate 0
4.5 7.0
- 24. Shutdowns scheduled Over Next 6 Months (Type. Date.and Duration of Eacht:
FUEL RECEIPT. MAY 1A. 1981. 2 WFFKS NA
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
- 26. Units in Test Status (Prior to Commercial Operation):
Forecast Achieved
~
INITIA L CRITICA LITY INITIAL ELECT RICITY COMMERCI A L OPER ATION 8204130371 810508 g,y PDR ADOCK 05000 R
/
AVERAGE DAILY UNIT POWER LEVEL 50-409 DOCKET NO.
LACBWR 3.lT 05-05-81 DATE COMPLETED BY TELEPIIONE
~
~
SiONDI APRIL 1981 DAY AVER AGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL "M
(MWe Net)
(51We-Net) 39 39 i
,7 2
39 18 39 3
40 i,
39 4
40 20 39 5
40 21 40 6
40 22 40 7
40 23 41 8
39 24 41 9
39 25 41 10 39 26 40 II 38 27 41 12 39 28 42 13 39 29 41 14 39 30 40 15 39 31 16 39 l
l INSTRUCTIONS On this format.hst the average daily unit power levelin MWe Net for each day in the reporting month. Compute to the nearest whole megawatt.
(9/77 )
o y
UNIT SilU1 DOWNS AND POWER REDUCTIONS DOCKET NO. 50-409 UNIT NAME LACBWR DATE 09 OR A1 REPORT MONTil APRIL 1981 COMPLETED BY L.S. GOODMAN TELEPilONE 608-689-2331 6
1 5;
3 k E4 Licensec
.E",
"o cause & Correctise
~
No.
Date
/-
ii 4
2ys Event g?
El Action to p
5i g
- p. m =
Report :
mV gU Prevent Recurrence t=
c-g u
6 NONE D
3 4
F: Forced Reason:
Method:
Exhibit G-Instructions S: Scheduled A Equipment Failure (Explain) 1-Manual for Preparation of Data B-Maintenance of Test 2 Manual Scram.
Entry Sheets for i.ieensee C. Refueling 3 Automatic Scram.
Event Repoit (LI.'R) File t Nt8RI.G.
D Regulatory Restriction 4-Other (Explain) 016II E-Operator Training & License Examination F Administrative 5
G-Operational Error (Explain)
Esinbit I Same Source 19/77) li Other iExplain)
A
NARRATIVE
SUMMARY
OF OPERATING EXPERIENCE At the Anset of the April 1981 reporting period, power generation continued at 85% Reactor Rated Thermal Power (39 MWe-Net). This power level has been scheduled to optimize power production by extending the period between refuel-ing outages.
From April 3 to Ap)ril 4, a slow power escalation to 88% Peactor Rated Thermal Power (40 MWe-Net was conducted. This power level was maintained until April 8, when power was returned to 85% Reactor Rated Thermal Power.
Oper-ation continued at this power level until April 20, when a slow escalation to 91% Reactor Rated Thermal Power (41 MVe-Net) was commenced. This power e
level was reached on April 23 and operation continued at this level until April 29, when power was decreased to 88% Rated Thermal Power, at which rate it remained throughout the remainder of the April 1981 reporting period.
i Significant maintenance activities performed during this reporting period are indicated on the attached Instrument and Electrical Maintenance and Mechanical Maintenance listings.
9 MECIIANICAL MAXNTEllANCE LER OR flATURE Of OUTAGE gA_LTUNCTION EQUIPMEllT MAINTENANCE NUMCER CAUSE RESULT CORRECTIVE ACTION POST-ACCIDENT SAMPLING FC-71-80-1 NA NA NA INSTALLATION OF NEW SYSTEM PR-0171 SYSTEM HANGERS / RESTRAINTS FOR FC-53-80-2 NA NA NA INSTALLATION OF NEW PIPING IN CONTAINMENT MR-3285 PIPE HANGERS / RESTRAINTS (VARIOUS)
MR-0577 1A SEAL INJECTION CORRECTIVE NA PLUNGER PACKING EXCESSIVE WATER REPACKED ALL THREE (3)
PUMP MR-0527 WORN OUT LEAKAGF PLUNGERS AND REPLACED PACKING ADAPT 0RS ON WEST PLUNGER SMALL WASTE WATER CORRECTIVE NA PACKING WORN OUT EXCESSIVE WATER INSTALLED NEW STEM
- METER, MR-0530 LEAKAGE PACKING, CUT AND NUT
?
LUBE OIL PURIFIER CORRECTIVE NA CRACKED DIAPHRAGM LEAKED THROUGH INSTALLED NEW DIAPHRAGM VALVE 92-24-025 MR-0556 AND COMPRESSOR 1A AND 1B STACK BLOWERS CORRECTIVE NA WORN OUT PULLEY CAUSED BELTS TO REPLACED PULLEYS AND BELTS MR-0572 WEAR AND SOUEAL-ING NOISE BATTERY RACK RESTRAINTS NES DWG.
NA NA NA FABRICATED RESTRAINTS FOR SK5101-063-6 SEISMIC CONTROL OF BATTEPIES f
APRIL 1981 If4STRUMENT A?iD ELECTRICRL MAINTENANCE 1 of 3 LER OR flATURE OF OUTAGE MALFUNCTION EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION SECURITY SYSTEM CCTV CORRECTIVE NA UNKNOWN POOR PICTURE ADJUSTED CAMERA 788 FOR MR-05I3 PROPER PICTURE r
SECURITY SYSTEM CHANGE CORRECTIVE NA IMPROPER AIR FLOW D00R HELD OPEN CLOSED WINDOWS IN ROOM 000R
.MR-0538 LOCKER ROOM i
SECURITY SYSTEM ROADWAY CORRECTIVE NA NORMAL USAGE SHORTED BALLAST REPLACED ROADWAY LAMP LIGHT OUT
.MR-0543 BALLAST SECURITY SYSTEM COMPUTER CORRECTIVE NA UNKNOWN SYSTEM OPERATIONAL NO MALFUNCTION FOUND CONTROL OT3 MR-0548 SECURITY SYSTEM CRIB CORRECTIVE NA UNKNOWN ALARM NOT RESET-ADJUSTED BALANCE ON HOUSE ROOF A25-2 MR-0557 ABLE ALARM UNIT SECURITY SYSTEM E-FIELD CORRECTIVE NA UNKNOWN ALARM NOT RESET-ADJUSTED BALANCE ON ALARM A19 MR-0557 ABLE ALARM UNIT SECURITY SYSTEM E-FIELD CORRECTIVE NA UNKNOWN INSULATOR MISSING REPLACED WIRE INSULATOR 4
INSULATOR MR-0581 TO FENCE SAFETY SYSTEM CH-1, CH-2, PREVENTIVE NA TEST DUE COMPLETED TESTS COMPLETED TECH. SPEC.
AND H 0tCH-3 TESTS FOR SAFETY SYSTEM i
2 1, 2-AND WATER LEVEL #3 NUCLEAR INSTRUMENT CH.
PREVENTIVE NA TEST DUE COMPLETED TESTS COMPLETED TECH. SPEC.
N-5 THROUGH N-9 TESTS N-5 THROUGH N-9 SAFETY SYSTEM POWER PREVENTIVE LER TEST REOUESTED COMPLETED TESTS CHECK OF TRIP POINTS FLOW 1 AND 2 81-05 FOR TEST SHEET CHANGE LIQUID WASTE MONITOR CORRECTIVE NA NORMAL USAGE CIRCUIT FAILURE, CLEANED METER RELAY MR-0542 WITHOUT ALARM CONTACTS WASTE WATER MONITOR FC-54-80-2 NA NEW INSTALLATION COMPLETED INSTALL-INSTALLED NEW FLOW METER ATION IN SYSTEM y
APRIL 1981 INSTRUMENT AND ELECTRICAL MAINTENANCE 2 of 3 LER OR NATURE OF OUTAGE MALFUNCTION EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION TUNNEL AIR MONITOR CORRECTIVE NA NORMAL USAGE MOTOR BEARINGS REPLACED MOTOR WITH MR-0554 BAD SPARE UNIT TURBINE BUILDING AIR CORRECTIVE NA UNKNOWN BURNED OUT POWER REPLACED RESISTOR IN MONITOR MR-0568 RESISTOR POWER SUPPLY AREA MONITOR POWER CORRECTIVE NA SHORT IN RELAY RELAY AND RESISTOR REPLACED RELAY AND SUPPLY MR-0574 C0IL BURNED OUT RESISTORS NUCLEAR INSTRUMENTATION CORRECTIVE NA SHORT IN TRANS-BURN 0UT OF TRANS-REPLACED WITH SPARE CH. N-3 (NEG.)
MR-0575 FORMER FORMER UNIT NUCLEAR TEST CHASSIS CORRECTIVE NA CONTAMINATION UNSTABLE READING CLEANED TEST SWITCH MR-0578 CONTACTS NUCLEAR INSTRUMENTATION CORRECTIVE NA OPEN WIRE IN INOPERATIVE HIGH REPLACED TRANSFORMER CH. N-3 (POS.)
MR-0582 TRANSF0PMER V0LTAGE IN POWER SUPPLY COMPONENT COOLING WATER CORRECTIVE NA TEST DUE COMPLETED TESTS TESTED PRESSURE GAUGES IB PRESSURE GAUGE MR-0533 CONTROL AIR DRYER CORRECTIVE NA CONTAMINATION DAMP AIR CLEANED AND LUBED PURGE MR-0536 VALVES TURBINE' ENTRY MONITOR CORRECTIVE NA UNKNOWN BLOWN FUSE REPLACED BLOWN FUSE MR-0541 FIRE HEADER FLOW CORRECTIVE NA CYCLIC PRESSURE LEAK IN DIAPHRAGM REPLACED FLOW UNIT ANNUNCIATOR MR-0523 SURGES WITH SPARE-WATER HEATER POTABLE CORRECTIVE NA HARD WATER ELEMENT AND CON-REPLACED HEATER ELEMENTS MR-0547 TACTOR BURNED OUT AND RELAY MR-0529 DECAY HEAT VALVE CORRECTIVE NA UNKNOWN INCORRECT INDI-RESET TO PROPER INDI-POSITION MR-0549 CATION CATION AUTOMATIC GAIN CONTROL CORRECTIVE NA TUNE-UP REQUEST COMPLETED TUNE-UP COMPLETED MODULE TESTING CH. 7 AND 8 MR-0530 MR-0552 l
APRIL 1981 IrtSTRUMENT AND ELECTRICAL MAINTENANCE 3 of 3 LER OR NATURE OF OUTAGE MALFUNCTION EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION CONTROL R0D DRIVE #10 CORRECTIVE NA WATER ON TRANS-INCORRECT CLEANED UNIT POSITION INDICATION MR-0555 MITTER POSITION AUXILIARY OIL PUMP FOR CORRECTIVE NA NORMAL USAGE OIL PUMP IN0PER-REPLACED MOTOR 1B REACTOR FEED. PUMP-MR-0566-ATIVE BEARINGS TURBINE BUILDING VENT CORRECTIVE NA FLY ASH AND DIRT DAMPERS IN0PER-CLEANED DAMPER INLET DAMPERS MR-0558 ATIVE MECHANISM e