yr March 31, 1982 Docket flos. 50-528, 50-529, 50-530 Arizona Public Service Company P. O. Box 21666 Phoenix, Arizona 85036 Attention: Mr. E. E. Van Brunt, Jr.
Vice President, Nuclear Projects IE BULLETIN NO. 82-01: ALTERATION OF RADIOGRAPHS OF WELDS IN PIPING SUBASSEMBLIES Gentlemen:
The enclosed Rulletin is forwarded for your information.
No specific actions are required of plants not listed on Table 1.
If there are any questions related to the applicability of this Bulletin please contact this office.
Sincerely, M it h nc5 by
- H Engon n e
R.11. Engelken Regional Administrator
Enclosure:
IE Bulletin 82-01 cc w/ enclosure:
F. W. Hartley, APS G. C. Andognini, APS 8204090360 820331 PDR ADOCK 05000133 G
PDR l
.0 Y
" "'"'I
...R1 B O P..
.ENGELKEN.
oan) 3/31/82
./31/82 3
.I sac ronu ais no w sucu o 40 OFFICIAL RECORD COPY
"~>-32 *
- SSINS No.: 6820 Accession No.:
8202041110 OMB No.:
3150-0084 E::piration Date: 3/31/83 IEB 82-01 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.
20555 l
March 31, 1982 IE BULLETIN N0. 82-01:
ALTERATION OF RADIOGRAPHS OF WELDS IN PIPING SUBASSEMBLIES Description of Circumstances:
On October 19, 1981, the U.S. Nuclear Regulatory Commission (NRC) was notified by Washington Public Power Supply System (WPPSS) that alterations were found in certain radiographs of 21 shop welds in piping subassemblies supplied to 4
their WPPSS-3 by Associated Piping and Engineering Corporation (AP&E) of Compton, California.
Further examination of essentially all AP&E radio-graphs previously sent to the site revealed alterations on 14 additional 1
radiographs associated with eight welds in quality Class 1 stainless steel piping of less than - nch wall thickness. All affected 29 welds in the thin-wall piping were reexamined radiographically in accordance with the ASME Code.
No evidence of unacceptable weld quality was identified.
The alterations consisted of artificial enhancement of the ASME Code specified penetrameter 4T-Hole image. This was apparently accom (1) touchup with a soft lead pencil, (2) plished in one of scribed or scratched three ways:
with a sharp object, or (3) indention with a sharp object. These forms of enhancement are very difficult to detect by normal film interpretation techniques (i.e., subdued background lighting). However, utilizing direct overhead lighting, the alterations may be detected by close inspection of the film surface reflections as the film is being manipulated by the observer at various oblique angles.
After this finding, an investigation was made at AP&E by the NRC Region IV staff on December 7-11, 1981.
The results of the investigation were reviewed at the Region IV headquarters and determined to be potentially generic.
On January 29, 1982, the specific l
plants potentially affected were identified by the regional office.
The investigation and review established the following:
t i
1.
Radiographs were altered on occasion by one Level II interpretor over a period of approximately eight years prior to the date of this investi-gation.
2.
The alterations were limited to the set of radiographs of.. welds submitted for customer review and approval.
IEB 82-01 March 31, 1982 Page 2 of 3 3.
The alterations involved welds associated with pipe wall thickness of less than -inch that used isotope radiography techniques and a number 10 or 12 penetrameter.
4.
Radiograph sets retained in AP&E file for WPPSS Unit 2 contained unaltered radiographs that did not exhibit the Code-required 2-4T t
penetrameter sensitivity.
5.
A number of nuclear plant sites receiving fabricated piping assemblies
-from AP&E may have similar discrepancies. The affected sites are listed in Table 1.
ASME Section III Code Rules, Articles flB-5000 and NC-5000, requires that weld quality acceptance of Class 1 and 2 piping be evaluated on the basis of radio-g raphy.
In radiography examination, meaningful interpretation of weld quality is dependent on the use of a radio' graphic technique of sufficient sensitivity as shown by the penetrameter image indicators on the film. The adequacy of technique sensitivity is confirmed by the ability to visibly discern the appropriate T-hole images of the penetrameter when evaluating the radiographs i
for weld quality in accordance with the governing Code rules.
Padiographs that have had penetrameter image quality indicators artificially enhanced by the discussed methods violate the intent of ASME Code reouirements. Accordingly, the following actions are necessary to independently reverify that the examined welds of the subassemblies fabricated by AP&E are acceptable for plant service.
Action To Be Taken by Apolicants for an 0]erating License and Holders of Active _ Construction Permits (Group 1, Ta ale 1):
1.
Determine on the basis of a 100 percent review of radiograph sets representing the shop fabricated quality Class 1&2 subassemblies provided by AP&E, whether the applicable ASME Code penetrameter sensitivity (2-2T or 2-4T as required) is unaltered, and clearly discernible, and that acceptable weld quality is demonstrated.
2.
In those cases where the specified penetrameter sensitivity is not discernible or is apparently enhanced in any manner, as by the methods discussed, weld quality interpretation may.be based on the equivalent or higher penetrameter sensitivity discernible on the film sets.
For example, for those radiograph sets for which the required 2-4T'penetra-meter sensitivity is not discernible, or found artificially enhanced on visual inspec+ ion, film interpretation of weld ouality may be based on the presence of discernible 2-2T or 2-1T sensitivity exhibited by the radiographs.
3.
Where conformance with Items 1 and 2 cannot be satisfied, appropriate steps shall be taken to ensure the acceptability of the affected welds l
in accordance with the apolicable ASME Section III Code requirements in effect for plant construction.
t
IEB 82-01 fiarch 31, 1982 i
Page 3 of 3 J
4.
The above actions are to be completed prior to issuance of an OL or within 90 days of receipt of this bulletin, whichever occurs first.
All quality assurance records reflecting the review findings and disposition of discrepancies identified shall be maintained and available for flRC review.
i 5.
A written report describing the findings and corrective actions taken, signed under oath or affirmation under provisions of Section 182a, Atomic Energy Act of 1954, shall be submitted within 30 days after completion of. Items 1 through 4 to the Regional Administrator of the appropriate TIRC Regional Office. A copy of the report is to be forwarded to the Director, Office of Inspection and Enforcement, flRC, Washington, D.C.
20555.
Actions To Be Taken by Applicants for Construction Permits or Utilities Whose Construction Permits Are Suspended or Delayed (Group 2; Table 1):
No action required except as noted in Item 2, below.
1.
For information only.
2.
In the event reactivation of construction or transfer, sale, or other consignment of the subject piping subassemblies to another nuclear plant site is contemplated, both the NRC and recipient oermit holder, or licensee, are to be notified of the disposition of said i
subassemblies under provisions of 10 CFR Part 21 regulations.
This request for information was approved by OMB under clearance number:
3150-0084. Comments on burden and duplication should be directed to the Office of Management and Budget, Reports Management, Room 3208, New Executive Office Building, Washington, D.C.
20503.
Attachments:
1.
Table 1 2.
Previously Issued IE Bulletins 1
IEB 82-01 March 31, 1982 TABLE 1 SITES WITH PIPING ASSEMBLIES FROM AP&E Group 1 Group 2 Grand Gulf Units 1&2 Bailly Unit 1 LaSalle Units 1&2 Black Fox Units 1&2 River Bend Units 1&2 Hartsville A1, B1, A2 & B2 Clinton Units 1&2 Phipps Bend 1&2 Shoreham Allens Creek Unit 1 Limerick Units 1&2 WPPSS-2 Nine Mile Point 2 Hope Creek Units 182 l
l l
l l
l l
1
l n.. 's i
IEB 82-01 March 31, 1982 PREVIOUSLY ISSUED IE BULLETINS 1
Bulletin -
Date of No.
Subject Issue Issued to I
81-02 Failure of Gate Type Valves 08/18/81 All power. reactor Supplement to Close against Differential facilities with an l
1 Pressure OL or CP 81-03 Flow Blockage of Cooling, Water 04/10/81 All power reactor To Safety System Components by facilities with an COR81CULA SP. (ASIATIC CLAM)
OL or CP and MYTILUS SP. (MUSSEL) 81-02 Failure of Gate Type Valves 04/09/81 All power reactor to Close Against Differential facilities with an Pressure OL or CP l
81-01 Surveillance of Mechanical 03/04/81 Specific power reactor
?