Final Deficiency Rept Re Steam Generator 2 w/1/2-inch Indication in Nozzle Outlet Weld Not Shown by Previous Radiographic & Ultrasonic Tests.Linear Indication Removed by Grinding.Not Reportable Per 10CFR50.55e
ML20050C434
Person / Time
Site: Palo Verde 
Issue date: 03/23/1982
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Faulkenberry B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
10CFR-050.55E, 10CFR-50.55E, ANPP-20511-GHD, NUDOCS 8204080499
Download: ML20050C434 (3)


Text

_ _.

s..

Docket Nos. 50-528/529/530 I

50 55(e) Report a

-JY s

..?<

21\\.Tff/rWM

)

{F>ffi:iMT.fil NY[COI.N] (D@NhW P. O. B O X 216 6 6. PHOENIX. ARIZON A 85036 March 23, 1982 ANPP-20511-GIID/BSK eMi U. S. Nuc1 car Regulatory Commission Region V C

D Creekside Oaks Office Park fj q

1450 Maria Lane - Suite 210 e

e to

ilk, Walnut Creek,~ California 94596-5368 e

r Attention:

Mr. B. II. Faulkenberry, Chief C

C D

Reactor Construction and Engineering Support Branch Subj ect:

Final Report - DER 81-54 A 50.55(e) Report Relating to Unit 1 Steam Generator #2 lias h" Visible Linear Indication In Nozzle Outlet Weld, i

Not Shown By Previous Radiographic and Ultrasonic Tests File:

82-019-026 1

4 l

D.4.33.2

Reference:

(A) Telephone Conversation between Eckhardt and G. Duckworth on December 30, 1981 (B) ANPP-20012, dated January 28, 1982 (Interim Report)

Dear Sir:

Attachest, is our final written report of the deficiency referenced above, which has been determined to be Not Reportable under the requirements of 10CFR505.55 (e).

Very truly yours, C(Q O LLL-E. E. Van Brunt, Jr.

APS Vice President Nuclear Projects ANPP Project Director EEVBJr/GHD:ske i

I Attacimient S

q, cc: See Attached Page 2

\\

@/

-)

J/

3' f\\ _' " R 7 l932 i

4'

' ;z: V ',23 g L*

kh

/.\\

g'\\'h /

D.

3 l

C204000499 820323

/,[

, i DR ADOCK 05000 82 7/

U, S. Nuclear Regulatory Commission Attention:

Mr. B. H. Paulkenberry, Chief ANPP-205il-CHD/BSK March 23, 1982 Page 2 cc:

Richard DeYoung, Director-Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.

20555 J. A. Roedel D. B. Fasnacht G. C. Andognini F. W.-Hartley J. M. Allen A. C. Rogers B. S. Kaplan W. E. Ide J. Vorces J. A. Brand A. C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R. W. Welcher R. M. Grant D. R. llawkinson L. E. Vorderbrueggen R. L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 87503 Ms. Patricia Lee Hourihan

-6413 South 26th Street Phoenix, Arizona 85040 i

k 4

-.vr-,

.-w-1

--,_--,,_,n r,,

--7---

--,n--

.r-.,.,,

FiaAL REPORT - DER 81-54 DEFICIENCY EVALUATION 50.55(e) r A PUBLIC SERVICE COMPANY (APS)

PVNGS UNIT 1 I.

Description of Deficiency During an internal cleanliness inspection of Steam Generator

  1. 2, e linear indication in the nozzle outlet (Bechtel Weld W-001) was discovered by visual inspection. The indication is approximately b" in length and appears to run parallel with the root bead in the root and heat affected zone. Prior to the visual discovery, the following NDE's had been previously completed as satisfactory on the subject weld.

o RT Inspected to ASME III, August 13, 1980 o PSE UT Test Per ASME XI, August 20, 1980 o PWHT Completed, September 24, 1980 II.

Analysis of Safety Implications The linear indication was removed by grinding. The area was visually inspected, and a surface examination (PT) was performed.

UT thickness measurement to verify minimum wall was performed and the minimum thickness obtained was 1.56", which is greater than the minimum wall requirements of 1.50".

No welding was required, Radiography was performed for information only. All examinations are acceptable; therefore, this condition is evalu-ated as Not Reportable since if left undetected and uncorrected, it would not have represented a safety significant condition.

III.

Corrective Action Nonconformance Report WC-502 will be dispositioned as "Use-As-Is" and will have the reports identified in II, included as attach-ments,