MAR 15 1982 Docket Nos: 50-369 and 50-370 APPLICANT:

Duke Power Conpany FACILITY:

McGuire Nuclear Station, Units 1 and 2

SUBJECT:

SUl111ARY OF VISIT TO ficGUIRE SITE ON ltARCH 5,1982 A visit was made to the McGuire Nuclear Station (17 niles north of Charlotte, N.C.)

on March 5, 1982 The purpose of the site visit was to observe and discuss the licensee's Eddy Current testing of the McGuire Model D steam generator. A list of attendees is shown as Enclosure 1.

The McGuire steam generator Edely Current Testing Progran was discussed with the licensee. Enclosure 2 presents a summary of the previous program undertaken. No stean gen 1.rator tube wear indications were observed. However, the previous program only involved testing of "A" steam generator. The current outage program will examine all four steam generators.

Pursuant to the staff's February 22, 1982, ietter to Duke Power Company, the licensee intends to subnit a detailed report describing the results of the current steam generator examination and a proposed restart progran by flarch 12, 1982, in advance of planned restart of Unit 1.

At the conclusion of the site visit, the staff visited the recently completed Electric Power Research Institute Non-destructive Evaluation Center. The HDE Center is located on a nine acre site in the University Research Park near Charlotte,.N.C. The Center was corpleted in February 1981, and has been designed and-staffed to translate the results of NDE research into field-qualified in-service inspection systems.

.5/

Ralph A. Birkel, Project Manager Licensing Branch tio. 4 Division of Licensing

Enclosures:

1.

Attendance List 2.

McGuire Eddy Current Program 4

..DL:Ud#.b?.LA:g:La.R.....QSE.f4...

omer >

su Nat >..R8irke1/4wrc.. f be..........Ehsam-

.3J. Q JB2......

s204070681 820315 Nac PDR ADOCK 05G00369

-)FFICIAL RECORD COPY usa m m - m em TP PiHD

  • VcCuire Mr. William 0. Park er, Jr.

Vice President - Steam Production Duke Pcoer Ccrpany P.O. Box 2178 422 South Church Street Charlotte, North Carolina 28242 cc:

Mr. A. Carr James P. O'Reilly, Regional Administrator Duke Power Corgany U.S. Nuclear Regulatory Conmission, P.O. Box 2178 Region 11 422 South Church Street 101 Marietta Street, Suite 3100 Charlotte, North Carolina 28242 Atlanta, Georgia 30303 Mr. F. J. Twogood Power Systems Divisior, Westinghouse Electric Corp.

P.O. Box 355 Pittsburgh, Pennsylvania 15230 Mr. E. J. Keith EDS Nuclear Incorporated 220 Montgomery Street San Francisco, California 94104 Mr. J. E. Houghtaling NUS Corporation 2536 Countryside Boulevard Clearwater, Florida 33515 Mr. Jesse L. Riley, President The Carolina Environmental Study Group 854 Henley Place Charlotte, North Carolina 28207 J. Michael McGarry, III, Esq.

DeBevoise & Liberman 1200 Seventeenth Street, N.W.

Washington, D. C.

20036 Shelley Blum, Esq.

1716 Scaler Street Raleigh, North Carolina 27608 Mr. Paul Bemis Senior Resident Inspector c/o U.S. Nuclear Regulatory Commission P.O. Box 216 Cornelius, North Carolina 28013

11 Q

i ATTEllDANCE LIST McGuire Nuclear Station, Units 1 and-2 Harch 4, 1982 DUKE POWER COMPANY W. A. Haller Russell P. Huschick A. L. Sudduth 4

C. W. Hendrix, Jr.

WESTINGHOUSE John V. Larson J. R. Schuties NRC STAFF Ralph A. Birkel Emett Murphy Alan Herdt Tom Ippolito J. Rajan Keith Wichman C. Y. Cheng Paul R. Bemis (Sr. Resident Inspector)

J. A. Jendrejczyk (Consultant - Argonne)

C. V. Dodd (Consultant - Oak Ridge Nat. Lab) i omen >

suamwe>

.j.

one>

NRC FOAM 318 00-80) NRCM Om OFFIClAL RECORD COPY use.m e-mm

[

NCGUIRE I MARCH, 19S2 EDDY CURRENT PROGRAM PREVIOUS TESTING November, 1981 - Af ter 50 Percent Power Operation Decenber, 1981 - After 75 Percent Power Operation Approxicately 170 Tubes in Ross 47, 4S, and 49 2etec MI2-12 (Multi-Frequency) Equipment Used 130, 200, 400, 550 Kh: Frequencies Used (Differ-ential Mode)

No Wear Type Indications Present

  • W $ h *? $

CURRENT OUTAGE PROGRAM All Steam Generators to be Examined Approximately 170 Tubes per Generator - Rows 47, 4S and 49 Ze t ec '112-12 (Multi-Frequency) Equipment Used 100, 300 Kh: (Absolute Mode) and 200, 400 Kh: (Dif-ferential Mode) Frequencies to be Used

i

\\

.\\

?

~M 2 21932> 3 asno MEETING

SUMMARY

DISTRIBUTION 2

a un rn zu r::mc, a, wax a

,,--.g--

M

Docket Filejc-J 6J f7Aj G. Lear

}9

NRC/PDR S. Pawlicki

/y Local PDR-V. Benaroya m

TIC /NSIC/ TERA Z. Rosztoczy LB #4 r/f W. Haass MAR 15 1982 H. Denton D. Muller E. Case R. Ballard D. Eisenhut W. Regan R. Purple R. Mattson B. J. Youngblood P. Check A. Schwencer

0. Parr F. Miraglia F. Rosa J. Miller W. Butler G. Lainas W. Kreger i

R. Vollmer R. Houston I,

J. P. Knight W. Gammill R. Bosnak L. Rubenstein F. Schauer T. Speis R. E. Jackson W. Johnston Attorney, OELD S. Hanauer OIE (3)

C. Berlinger i

ACRS (16)

F. Schroeder R. Tedesco D. Skovholt i

M. Ernst K. Kniel

{

NRC

Participants:

G. Knighton R. Birkel A. Thadani C. V. Dodd (Consultant)

D. Tondi E. Murphy J. Kramer

[

A. Herdt D. Vassallo l

T. Ippolito P. Collins J. Rajan D. Ziemann l

K. Wichman F. Congel l

C. Y. Cheng J. Stolz l

P. R. Bemis (Sr. Res. Insp.)

M. Srinivasan J. A. Jendrejczyk (Consultant)

R. Baer q