ML20050B837
| ML20050B837 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island |
| Issue date: | 01/22/1981 |
| From: | Mayer L NORTHERN STATES POWER CO. |
| To: | James Keppler NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| References | |
| REF-SSINS-6820 IEB-79-01B, IEB-79-1B, NUDOCS 8204070472 | |
| Download: ML20050B837 (13) | |
Text
l 0
Northern States Power Company
~
9 e
J_
414 Nicollet Mall D. E. Gilberts Minneapohs. Minnesota 55401 senior vice President lelephone (612) 330-6071 Power Supply January 22. 1981 Mr. James G. Keppler Director, Region III Office of Inspection and Er.forcement U. S. Nuclear Regulatory Commission 799 Roosevelt Road
,, g ) 4 % / D Glen Ellyn, IL 60137 Ny
.-n s
i
Dear Mr. Keppler:
Gk. #'?>'
Y.'
f; V~
pqG N PRAIRIE ISLAND NUCLEAR GENERATING PLAhT l II~
gj Docket Nos. 50-282 and 50-306
References:
S 1.
NSP Letter to Mr. J. G. Keppler, NRC Region III, October 31, 19
- / *
- l. #
2.
NRC Office of Inspection and Enforcement; IE Supplement No. 3 to Bulletin No. 79-OlB, October 24, 1980 3.
NSP Letter to Director of Nuclear Reactor Regulation on January 1, 1980 Lessons Learned Implementation, March 13, 1980 IE Supplement No. 3 to Bulletin No. 79-OlB required submit'.al of qualification information for equipment resulting from TMI Action Plan requirements and equipment which is required to achieve cold shutdown.
Qualification Information for Installed TMI Action Plan Equipment Safety grade subcooling margin monitors have been installed in Unit 1 and 2.
The temperature input is derived from multiple core exit thermocouples and the pressure input is derived from Reactor Coolant System (RCS) wide range pressure. Outstanding items concerning qualification of the temperature and pressure inputs have been previously addressed in Reference 1.
Until the inputs to the subcooling monitors have been upgraded, the P-250 plant computer has been programmed to accept the best available temperature and pressure inputs; see Reference 3.
Qualification relating to components not previously addressed is reported in Attachment A of this response.
Qualification information for future TMI Action Plan equipment will be sub-mitted by the pre-implementation or implementation review date as required DOj by Reference 2, Supplement 3 to Bulletin 79-OlB.
- /
Equipment Required to Achieve Cold Shutdown The November 1, 1980 response to Bulletin 79-OlB has been reviewed to identify additional electrical equipment necessary to achieve and maintain a Cold Shutdown condition.
8204070472 810122 PDR ADOCK 05000282 JAN 2 61981 PDR
e b
Mr. James G. Keppler o
Page 2 January 22, 1981 The residual heat removal system, while not necessary, would, if available, normally be used to cool the plant to cold shutdown. Additional electrical equipment normally used would be the nonsafeguarda RHR suction valves from both RCS hot 1 cgs and the nonsafeguards loop B RHR return valve.
The environ-mental specification and qualification of these components is identified in Appendix A of this response. Outstanding items have been identified for specific accident related environmental conditions. NSP intends to continue investigation of these outstanding items.
In the event that the residual heat removal system components identified for
.cooldown are not available, the auxiliary feedwater system along with the secondary side power-operated relief valves would be used to bring the plant to a safe cold shutdown condition. The safety injection pumps and residual heat removal pumps, taking suction from the refueling water storage tank or containment sump, would be used to maintain reactor coolant system inventory.
Use of the steam generators as a forced cooling water heat exchanger at lower temperatures is discussed in FSAR Section I.8.
Yours truly, 0
D. E. Gilberts Senior Vice President Power Supply cc:
Mr. G. Charnoff Mr. C. D. Feierabend NRC Office of Inspection and Enforcement Washington, D. C.
20555 Enclosures DEG:nk
6 UNITED STATES NUCLEAR REGULATORY COMMISSION NORT11ERN STATES POWER COMPANY PRAIRIE ISLAND NUCLEAR GENERATING PLANT Docket No. 50-282 and 50-306 LETTER DATED JANUARY 22, 1981 RESPONDING TO NRC REQUEST FOR INFORMATION IN IE BULLETIN 79-01B Northern States Power Company, a Minnesota corporation, by this letter dated January 22, 1981, hereby submits information in response to NRC request for information concerning IE Bulletin no.79-01B.
This request contains no restricted or other defense information.
NORTHERN STATES POWER COMPANY By h,
W L 0 Maypt Manager of Nuclear Support Services On this MM day of & m m
/98[,beforemeanotarypublicinand for said County, personallyvappearedfL 0 Mayer, Manager of Nuclear Support Services, and being first duly sworn acknowledged that he is authorized to execute this document on behalf of Northern States Power Company, that he knows the contents thereof and that to the best of his knowledge, information and belief, the statements made in it are true and that it is not interposed for delay, O~
a ru
.::..:: :.: :.::::.:7 ffe%
BETTY J. DEAN o
Notanv evotic. uiNNtsotA ::
?
RAMSEY COUNTY
!{
.:. :. ^^ ^, u Commism Empes Dec to 1987 l r
^
..~ ~ :: ^ ^ ^. :. :0
j c
MASTI ' LIST nev. 6 1/9/81 "A
SYSTE!!: INSTRUMENTATION & PROTECTION (R.C.)
COMPONENTS PLANT IDENTIFICATION INSIDE PRIM.\\RY OUTSIDE PRIMARY
?iU!IBER GENERIC NA?fE CONTAI:01ENT CONTAI:01ENT I
21146 Pressurizer Pressure X
I 21147 Pressurizer Pressure X
l 21148 Pressurizer Pressure X
l 21150 Pressurizer Pressure X
l 21154 Pressurizer Pressure X
i 21155 Pressurizer Pressure X
l 21156 Pressurizer Pressure X
deb l
21157 Pressurizer Pressure X
l l
t 24041 Pressurizer Level i
X 24042 Pressurizer Level X
i i
24043 Pressurizer Level X
l 24046 Pressurizer Level X
l l
24047 Pressurizer Level X
24048 Pressurizer Level X
- 15197 RTD (Narrow)
X i
- 15199 RTD (Narrow)
X i
- 15201 RTD (Narrow)
X f
- 15203 RTD (Narrow)
X
- 15207 RTD (Narrow)
X
- 15209 RTD (Narrow)
X
- m
- 15211 RTD (Narrow)
X
- 15213 RTD (Narrow)
X A.11.ii
'UU "ER LIST Rev. 6
.jfP' 1/9/81 SYSTEM:
INSTRIBENTATION & PROTFNTO'I (R.C) i COMPONENTS PLANT LOCATION IDENTIFICATION INSIDE PRIMARY OUISIDE PRIIl' RY A
NUMBER GENERIC NA'IE CONTAINMENT CONTAINMENT
- 15228 RTD (Narrow)
X
- 15230 RTD (Narrow)
X
- 15232 RTD (Narrow)
X
- 15234 RTD (Narrow)
X
- 15238 RTD (Narrow)
X
- 15240 RTD (Narrow)
X
- 15242 RTD (Narrow)
X
- 15244 RTD (Narrow)
X
- TNE Installe d Lessons Learned-Supplement 3
l i
4 er i
a e
i A.ll.iii' i
n
_a Rev.'6 SYSTD4 CX24PONDE EVAI11ATION VERKSIIEE.T
. UNIT:
. Prairie Island 1 & 2 DOCKET:
'50-282 & 60-306 N
W,E OmmE EQUIH4E!E DESCRIPTION PARW1'ER j SPIIIFICATION QUALIFICATION SPlf.
G.IALIF.
5 Elf 0D ITDIS SYSTU4: Instrumentation & OPEFATIM PIR E ID 10.:
Prot.
Type See. Note 1 3 days 2 weeks 6
4 g Test NONE
- ~
00tTONDE:
TDIP.
I Type
~
RTD Deg. F 268 F 320 F 1
4 Test NONE WMJFICI'JRE:
PRESSURE Type l
W/SSTFN (PSIA) 60.7 psia 80.7 psia 1
4 Test NONE i
!DDEL IEEER:
PJ21.T1VE 6
i DM 11834B 100%
100%
5 4
es NONE (t)
~
l l
'o M ETION:
CIID1ICAL II B0 /Na0ll 1.146% ll B0 DY 3 3 3 3 Type RCS Temp. Narrow SPIF3 pil 9.0-9. 5 wt 17% Na0li 2
4 Test NONE
~
~~~7 ACCURTCY: SPIR.
5%
7 DDON: 2-3%
PADIATION 3.6 x 10 Rad 5 x 10 Rad 3
4 Tes NONE
i G V "
4 Test NONE j
LOCATION: Containment l 12 years FI/DCO leNEL ELEV: 706' '
GUE,-
NONE Yesk Not Required I.!UVE FI/JOD LEVEL:
i
- DOCUM17EITION REFERRCES:
IDTI.}:
1)
FSAR Chapter 5 Figure 5.2-7 1)
Includes: 15197 2)
FSAR Chapter 6 Section 6.4.3 15199 15201 3)
FSAR Chapter 7 Page 7.5-12 15203
~4)-
WCAP 9151, September 1977 5)
FSAR Chapter 5 Tabic 5.4-4 15207 15209
- 6) -Engineering Evaluation 15211 15213
.h j
.. f + '-
Rev. 6 SYSTEM CCEPONE2R EkeMTION VCPSSFELT 1/9/81 UNIT:
Praire Island 1 & 2 DOCKET
- 50-282 & 50-306.
AUIRIE2.T DESCRIPTICN PAPNET. ER SPECIFICATION QUALIFICATION SPT:C.
QUALIF.
MEnlOD '
ITDG SYSTD4: Inst rumentat ion 6 OPERATIN3 PIANT ID !O.:
Prot.
Type-See Note 1 3 days 2' weeks l
6 4
Test NONE T
CCEIONE2R:
IntP.
Type l Test RTD Deg. F 268 F 320 F 1
4 NONE li W FACIUPE:
PPFSSUIE l
NONE l
Type e
Rosemount (PSIA)
', 60.7 psia 80.7 psia 1
4 Test i
[
t
~
~J l. MODEL IGBER:
IELATIVE l
f 176 KF 100%
100%
5 4
s NONE EfE CISMI N 11 B0 /Na0li 1.146% 11 B0 o ~
- 3 3 3 3 Type w
- ACCURACY: SPFC.
5%
- - pH 9.0-9. 5 by wt. 17% Naoll 2
l 4
Test NONE g
RCS Temp. Narrow SPPvTi DD ON: 2-3%
RADIATION 3.6 r. 10 Rad 5 x 10 Rad 3
4 Test NONE l SFJWICP.: RCS Unit 2 q
l 1.'JATION: Containment I 12 years 4
e NONE i
FI!J FGIEL ELEV: 706'i SU"
~
~
~
~
~'
l A'rNE E"OOD LEVEL: Yes Not Required NONE L__
- DVJMRATION RWJ:NCPS:
IUI"p:
~
1)
FSAR Chapter 5 Figure 5.2-7 '
1)
Includes:
15228, 15230, 15232, 15234 2)
FSAR Chapter 6 Section 6.4.3 15238, 15240, 15242, 15244 3)
FSAR Chapter 7 Page 7.5-12
- 4) 'WCAP 9157, September 1977 5)
FSAR Cahpter 5 Table 5.4-4 I
- 6) Engineering Evaluations m.
r-MAF.ER LIST Rev. 6 1/9/81 9
SYSTEM:
Residual lient Removal (Ril)
COMPONENTS I
PLANT LOCATION IDENTIFICATION INSIDE PRIMARY OUTSIDE PRIliARY NUMBER GENERIC NAME CONTAINMENT CONTAINMENT 11 Motor X
12 Moto r X
21 Mo to r X
22 Moto r X
' CV-312 35 Limit Switches X
CV-31236 Limit Switches X
ar CV-31237 Limit Switches X
CV-31238 Limit Switches X
CV-31239 Lirit Switches X
CV-31240 Limi t Switches X
j
- 32066 Valve Operator X
- 32164 Valve Operator X
- 32165 Valve Operator X
- 32169 Valve Operator X
- 32192 Valve Operator X
- 32193 Valve Operator X
- 32230 Valve Operator X
'*32231 Valve Operator X
[
l
- 32232 Valve Operator X
+
l d[
- 32233 Valve Operator X
- Cold Shutdpwn Equipment - Supplement 3 A.17.1
-\\'
A
)*
Rev. 6 SYSTF14 CEMPONH7f EVALUATION HORKSHEET 1/9/81 UNIT:
Prairie Island'1 & 2 DOCKET. :
50-282 & 50-306 DWIRISTr DESCRIPTION PAIW2T. ER SPECIFICATION QUALIFICATION SPEC.
QUALIF.
ML'HIOD ITDIS SYSIB4: Residual Heat OPERATIIC l
Type PI1NP ID 10.: Removal 1 TDIE 69 Ilours 6
Test NOTE 2 See Note 1 O'EPONCfr:
TC4'.
pe NONE
' Valve Operator Deg. F 268 F 325 F 1
4 l Test EMJFACIURE:
PRESSURE Type (PSIA) 60.7 psia 74.7 psia 1
4 Test NONE I
._ _ _ __ y FCDEL NUMBER:
RELATIVE I
Type g
!!RilDIT'l 100%
100%
5 6
Test NONE
?"
SMB-1
(%)
II B0 /Na3 2 3S0l C
FUICTION:
Q DiICAL ll B0 /Na011 3 3 Type 3 3 SPPI6Y pil 9.0-9. 5 Naoli pil 7.85 2
4 i Test NONE l
RilR Isolation l
l ACCUPIC': SPEC.
NR Type l
NONE 7
8 DDON: NR RADIATION 3.6 x 10 Rad 2.04 x 10 Rad 3
4 Test SEINICE: 11, 12, 21, 22' Type Test NONE l
na ent i
IOCATION:
FIDOD LLVEL ELII/: 706 '
SUB-NONE I4EPSENCE Not Required ASOVE FIDOD LEVEL: Yes 1
IN*
_DO_CUMENritTION REFITCTSS:
1)
FSAR Chapter 5 Figure 5.2-7 1)
Valves Include: MV 32165 MV 32193 2)
FSAR Chapter 6 Paragraph 6.4.3 MV 32231 3)
FSAR Chapter 7 Page 7.5-12
. 4) WCAP 7410-L Dated December 1970 &
MV 32232 WCAP 7744 Dated August 1971.
5)
FSAR Chapter 5 Table 5.4-4 2)
Reference attached letter, this 6)
FIRL F-C3271 Dated February 1972 response.
9-
l q
g Rev. 6
- ~
SYSTEM CIEPOtfr:fr LVAIEATION 1rCPESIIEET 1/9/81 UNIT:
Prairie Island 1 & 2 D3CKLT:
50-282 & 50-306-1;UIIGH2C DOCUSETTATION REF*
Ql1%IF OUTSTANDUC
-ITJUIR412TT DESCRII'rION l
PAPMunER SPECIFICATION QUALIFICATION SPIR.
QUALIF.
ML*DIOD l'11FS SYSTF14: Residual Heat OPr3ATRX3 Type PIRTT ID !O.: Removal TIME _
69 Hours 6
Test NOTE 2 See Note 1 OJMPONI21r:
'IEMP.
Type 268 F 325 F 1
4 Test NONE Valve Operator 939, p a
_... = _
MA!UFACIURE:
PRESSURE Type Limitorque (PSIA) 60.7 psia 74.7 psia 1
4 Test NONE i
w oun-..
=
Type PODEL ID*BER:
P121sTIVE f
SMB 100%
100%
5 6
Test NONE FUNCTION:
L 'T31I N H B0 /Na0ll ll B0 /Na3 2 3S0/
3 3 Type 3 3 lpH9.0-9.5 Na0li pH 7.85 2
l 4
Test NONE I
RHR Isolation SPRAY ACCURACY: SPEC.
NR
[
]
.g.ypg DHON: NR PADIATION 7
8 3.6 x 10 Rad 2.04 x 10 Rad 3
4 Test NONE l
._[
SWICE: RilR. Loop i
Type Suction tc,nyj
- 19. 210N: Containment 40 Years 4
Test NONE
[-
fin 01EVEL ELIN: 706r 3.g;;_
I J.POVE FIDDD LEVEL: No NOTE 2 J
._.1_
- IrmiEt7 RATION ic2im2CE3:
INE:
')
FSAR Chapter 5' Figure 5.2-7 1)
Valves Include: MV 32164 2)
FSAR Chapter 6 Paragraph 6.4.3 FN 32192 3)
FSAR Chapter 7 Page 7.5-12 MV 32230
- 4).UCAP 7410-L Dated December'1970 &
IN 32233 WCAP 7744 Dated August 1971 2)
Reference attached letter, this
- 5).FSAR Chapter 5 Tabic 5.4-4 response.
6)
FIRL F-C3271 Dated February.1972
-a
m
.. g '
Rev. 6 I
SYSTEM GNPONENT EVALUATION VERKSIIEET UNIT:
Praire Island 1 & 2 DCOTT:
50-282.& 50-306 ECUIIMIITT DESCRIPTION PAPNIUTER SPI:CIFICATION QUALIFICATION SPlc.
QUALIF.
ME1110D ITE26 SYEN: Residual Heat CPEl&TII7i PIA!TP ID 10.: Removal Type 6911 urs 6
I Test NOTE 2 See Note 1 l
.g.
e COMPOTE 7F:
TD1P.
l Test Valve Operator Dog. F 268 F 325 F 1
4 NONE l Type frcCFAC'IUFE:
PluSSURE Limitorque (PSIA) 60.7 psia 74.7 psia 1
4 Test NONE MODEL IE:BER:
PJ2ATIVE
'y Type IUiIDI'iY y
S MB-0 100%
100%
5 6
Test NONE 1
g)
FUNCTIOM: RSDL llT CIIiMICAL ll B0 /Na3 2 3S0/
ll B0 /Na0ll 3 3 3 3 Type le P B Return gppAy pil 9.0-9.5 Na0li pil 7.85 2
l 4
Test NONE ACCUPICY: SPEC.
NR I
Type DRDN: NR RADIATION 7
2.04 x 10 Rad 3
4 Test NONE 8
3.6 x 10 Rad SEIWICE: Unit 1 & 2
[--
Loop Injection Line Agrn
'lype
' ICCATION: Containmen t 40 Years 4
Test NONE l
FIfyJ) Lt. VFL ELEN: 70F SUb-l
~
7 MEICE E ACOVE F1 COD IEVEL: Yes Not Required NONE
_. _ _.._J
- COCUMrNTATION REFEPJ1CIE:
INE*
1)
FSAR Chapter 5 Figure 5.2-7 1)
Valve Include: MV 32066 2)
FSAR Chapter 6 Paragraph 6.4.3 MV 32169
~. 3)
FSAR Chapter 7 Page 7.5-12
- 4) WCAP 7410-L Dated December 1970 &
2)
Reference attached letter, this WCAP 7744 Dated August 1971 response.
5). FSAR Chapter 5 Tabic 5.4-4 6)
FIRL F-C3271 Dated February 1972
y Rev. 6 1/9/81 MASTER LIST
-9 SYSTEM:
480V MTSC AUX (EB)
COMPONENTS PLANT LOCATION IDENTIFICATION INSIDE PRLMARY OUTSIDE PRIMARY NUMBER GENERIC NAME CONTAINMENT CONTAINMENT
- 1LAl Motor Control Center X
- lLA2 Motor Control Center X
- 2LAl Motor Control Center X
- 2LA2 Motor Control Center X
- Cold Shutdown Equipment - Supplement 3 f
l i
l i-i A.23.1
l i
)
~[
Rev. 6 I/9/01 SYSTEM CCMPONDir LVALUATION HCPSSHEFJr (IRT:
Prairie Island 1&2 DOCKET:
.50-282 & 50-306 E2UIH4I2TP DESCRIPTION PAPNEIER SPECIFICATION QUALIFICATION SPEC.
CXJALIF.
FEDIOD IID'S SYSTD1:480V_ Misc Aux (EB.) OPERATR E PIIME ID:D.:
TRE Continuous NOTE 2 See Note 1 COM00taff:
TEM?.
Motor Control Center W. F -
210 F 1
NOTE 2, 3
!@llfFACTUTE:
PPESSURE l
General Electric (PSIA) 15.2 psia 1
NOTE 2, 3 PDDEL !UGER:
RELATIVE N
!!GilDITY I
F 7700 Line Control (g)
!100%
1 NOTE '. 3 FUNCTION:
OID11 CAL l
~
~~
l 1
480 Volt MCC' gppny Not Required Not Required NONE l
ACCURACY: SPEC.
NR DEMON: NR PJ4DIATIO!!
20 mr/hr Not Required 2
3 NOTE 4
SERVICE: Safeguards AGD73 ILUsTION: Aux Bldg l
~
]
E"JJOD LINEL ELEV:
NR l SUli-FSOVE FIf)OD IEVEL: NR Not Required NONE
- P/X1MlfrATION le.meKTS:
Wr"S:
1)
FSAR Appendix 1, para I.11.1 1)
MCC's; ILA1, ILA2, 2LAl, 2LA2
~
2)
Design Review of Plant Sheilding and Environmental 2)
Reference attached letter, this response.
Qualification of Equipment for Spaces / Systems outside 3)
Only when a llELB occurs.
Containment which may be used in Post. Accident 4)
Only when a LOCA occurs.
Operations - Part I; July 1,1980.
- 3) Engineers Evaluation 9
- - - - -. - -