Text
f
/'p e r o,c, v
UNITED STATES
-[;
NUCLEAR REGULATORY COMMISSION f
C WASHINGTON D. C. 20555
's, k?J@d/sf f
%,,......r fiarch 31,198?
Alan S. Rosenthal, Esq., Chairman Dr. John H. Buck Atomic Safety and Licensing Atomic Safety and L'. censing Appeal Board Appeal Board U.S. Nuclear Regulatory Comnission U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Washington, D.C.
2055 %0$?L/
Christine N. Kohl, Esq.
'. ) '
ve, Atomic Safety and Licensing fg Y
Appeal Board f;
\\,
m
,m
<J
'l U.S. Nuclear Regulatory Commission
%
- p [b N p & l7 2
Washington, D.C.
20555
/g Q%
kff In the ftatter of 4
h#"4h4 Sacramento Municipal Utility District g
g (Rancho Seco Nuclear Generating Station)
Dear Appeal Board Members:
Your Menorandurr and Order dated March 8, 1982, requested NRC Staff responses to four questions pertaining to the HPI oczzles at Rancho Seco, Crystal River and Oconee.
Responses to these four questions are provided in an enclosed (11 nenorandum fron Thomas M. Novak, Assistant Director for Operating Peactors, Division of Licensing to myself, dated March 31, 1982, and (2) er affidavit of Mark L. Padovan, dated March 31, 1982.
- Singrely, o
nas d,;
x/ d:
r p
Richard L.
lack Counsel for NRC Staff
Enclosures:
As Stated cc:
(w/ enclosures)
James S. Reed, Esq.
Dr. Richard F. Cole Michael H. Remy, Esq.
Mr. Fredrick J. Shon David S. Kaplan, Esq.
Herbert H. Brown, Esq.
Lawrence Coe Lanpher, Esq.
Thomas A. Baxter, Esq.
Docketing and Service Section Atomic Safety and Licensing Atomic Safety and Licensing Appeal Board Board Panel Christopher Ellison, Esq.
Dian Grueneich, Esq.
Mr. Michael R. Eaton DESIGNATED ORIGINAL 8204020291 B203 Certified By fjd ' _
f
{DRADOCK05000 2
PDR g7
$//