ML20049J894

From kanterella
Jump to navigation Jump to search
Monthly Operating Repts for Sept 1981
ML20049J894
Person / Time
Site: Oconee  
Issue date: 10/15/1981
From: Reavis J
DUKE POWER CO.
To:
Shared Package
ML20049J893 List:
References
NUDOCS 8203290193
Download: ML20049J894 (16)


Text

..

OPERATING DATA REPORT 50-269 DOCKET NO.

DATE 10-15-81 COMPLETED BY

.J.

A. Reavis TELEPHONE 70A 171-R552 OPERATING STATUS

1. Unit Name:

Oconee Unit 1 Notes

2. Reporting Period: Septernber, 1981 Year-to-date and cummulative capacity factors are calcu-
3. Licensed Thennal Power (> twt 2568 g

g

4. Nameplate Rating (Gross MWe :

934 g

886 5.. Design Electrical Rating (Net tWe):

dependable capacity.

6. Maximum Dependable Capacity (Gross MWe):

899

7. Maximum Dependable Capacity (Net MWe):

860 S. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:

None

9. Power Level To Which Restricted. If Any (Net MWe):

None

10. Reasons For Restrictions. If Any:

This Month Yr..to.Date Cumulative

!!. Hours in Reporting Period 720.0 6,551.0 71,976.0

12. Number Of Hours Resctor Was Critical 0.0 3,689.2 50,975.2
13. Reactor Reserve Shutdown Hours
14. Hours Generator On.Line 0.0 3,658.7 48,242.8
15. Unit Reserve Shutdown Hours
16. Gross Thermal Energy Generated (MWH) 0 8,990,912 113,445,299 17 Gross Electrical Energy Generated (MWH) 0_,

3,174,500 39,476,330

18. Net Electrical Energy Genersted (MWH)

- 2.222 3.015.134 37.363.143

19. Unit Service Factor 0.0 55.9 67.0
20. Unit Availability Factor 0.0 55.9 67.1
21. Unit Capacity Factor tusing MDC Net) 0.0 53.5 60.2
22. Unit Capacity Factor (Using DER Net) 0.0 52.0 58.6 l
23. Unit Forced Outage Rate 0.0 13.8 16.8

-24. Shutdowns Scheduled Over Next 6 Months (Type. Date.snd Duration of Eschi:

Currently Refueling i

25..lf Shur Down At End Of Report Period. Estimated Date of ',::rtup:
26. Units in Test Status iPrior to Commercial Operation):

F' recast Achieved t

INITIA L CRITICALITY INITIAL ELECTRICITY COMMERCIA L OPER A TION 8203290193 811015 PDR ADOCK 05000269 R

PDR pipq n

50-269 DOCK ET NO.

tlNil SillrlllOWNS AND H)WI.R Hl:puriloNs UNIT NAMr.

Oconee Unit 1 DATE 10-15-81 Hl:l'Olti MONill September, 1981 COMPLET ED llY J. A. Reavis 1ELErilONE 704-373-8552

. y

5 ~4 l.kcpice g1, 3 u. :

=

. i _:-

c Cause & Currective

_5 -',,

N...

17.ite 3

gy
ggen, y

p 3 ;

d I_

E 5g=

Reinnt e tE 0 EO Psevent Recustensc

{

v o

5 81-09-01 S

720.00 C

RC FUELXX Scheduled refueling and inspection (10 year) continues.

Required modificatiohs in progress.

l 2

.I l

l '.- l e ni cil Reason :

Mellnati:

Exhibit G. Instructhms S Siliciluteil A l'iiuipmeni 1:ailuie !! spl.nn) 1 M.nnial for Pseparation of Data ll.Maintenante of Tes

2. Manual Sesam.

1:nis) Streets l'or 1.icensee C.Relucimg

.l. Autoni.itic Ss ram.

liveni Repost il l'HI File INtilti.G.

1).Regul.alos) RcStitsllent

-l-()tlice ll.xpIJHil Ol til I 1 Opcianos Isaming.i I siesiv i.saenm.ation l' dilllitnist 0JllVe b

G Oper.ation.il 1 :sor likpl.nni li.shiliit 1 Same Source l'8/111 11 Ollies libpl.im p m

I AVERAGE D AILY UNIT ?OWER LEVEL 50-269 DCCKET NO.

Oconee Unit 1 gy.g.;.

10-15-81 DATE COMPLETED BY J. A. Reavis TELEPHONE (70/4373-8552 September, 1981

.\\t0 NTH DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY ?OWER !.EVEL (MWe-Ned i.stwe.Nec 3 g

1,,

18 3

gg 3

g

,4 9

~

10 5

t!

I, 23 13 9

g4 20 l$

J$

i 16 INSTRUCTIONS l

dn t. tis (cr:-st. list :.ie aer:ge f:ily ;. : ; :we. 'e.,ei., uwe.se..n en,g...,...,.

.: nearest sneie..e;;w:::

e4

)

i e

i MONTHLY REFUELING INFORMATION REOUEST 1.

Facility name:

Oconee Unit 1 2.-

Scheduled next refueling rhutdown:

June, 1981 3.

Scheduled restart following refueling:

January, 1982 4

i 4.

Will refueling or resumption of operation thereafter require a technical specification change or other license a=endment?

Yes If yes, what will these be?

Technical Specification Revision i

i l

1 t

If no, has reload design and core configuration been reviewed by Safety

{

Review Committee regarding unreviewed safety questions?

NA If no, when is review scheduled?

NA

[

i 5.

Scheduled date(s) for submitting proposed licensing action and supporting info r=a tion : _ Submitted May 29, 1981 t

6.

I=portant licensing considerations (new or different design or supplier, j

unreviewed design or perfor=ance analysis methods, significant changes in design or new operating procedures).

None 1

i 1

1 i

l 7.

Nu=ber of fuel asse=olies (a) in the core:

0 (b) in the spent fuel pool: 542*

l i

8.

Present licensed fuel pool capacity:

1312*

Size of requested or planned increase:

None l

9.

Projected date of last refueling which can be acco==odated by present licensed capacity:

DUKE PO'JER COMTA2U Date: October 15, 1981 Nase of

Contact:

J. A. Reavis l

i l

  • Represents total for the combined Unit 1 & 2 Spent Fuel' Pool

DOCKET NO:

50-269 UNIT:

Oconee Unit 1 DATE:

10-15-81 NARRATIVE

SUMMARY

MONTH:

September, 1981 Refueling / ten year inspection / required modifications /other NSM's continue.

Reactor core support assembly repair is in progress.

e 6

9

\\

OPERATING DATA REPORT DOCKET NO.

50-270 DATE 10-15-11 i

COMPLETED BY

.J.

A. Reavis TELEPHONE 7nA_171 R552 OPERATING STATUS Oconee Unit 2 Notes

1. Unit Name:
2. Reporting Period: September, 1981 Year-to-date and cummulative capacity factors are calcu-
3. Licensed Thermal Power Qiht):

2568 lated using a weighted

4. Nameplate Rating (Gross MWel:

934 886 5.. Design Electrical Rating (Net MWe):

dependable capacity.

6. Ma.timum Dependable Capacity (Gross MWe):

899

7. Maximum Dependable Capacity (Net MWe):

860

3. If Changes Occur in Capacity Ratings (!! ems Number 3 Through 7) Since 1.ast Report. Give Reasons:

Nor.e

9. Power Level To Which Restricted. If Any (Net MWe):

None

10. Reasons For Restrictions. If Any:

This Month Yr. to.Date Cumulative

11. Hours In Reporting Period 720.0 6.551.0 61.896,0
12. Number Of Hours Reactor Was Critical 179.4 5.709.1 44.814.0
13. Reactor Reserve Shutdown Hours
14. Hours Generator On Line 175.7 5,667.2 43,842.9
15. Unit Reserve Shutdown Hours
16. Gros: Thermal Energy Generated (MWH) 379,371 13,689,861 103,785,976 1*

Gross Electrical Energy Generated (MWH) 128,42,0,

' 716.840 35,329,076

!$. Net Electrical Energy Genersted (MWH) 115,685 4,502,331 33,544,897

19. Urut Service Factor 24.4 86.5 70.8
20. Unit Availability Factor 24.4 86.5 70.8
21. Unit Capacity Factor (Using MDC Neri 18.7 79.9 62.8
22. Unit Capacity Factor IUsing DER Net) 18.1 77.6 61.2 75.6 9.3 16.9
23. Unit Forced Outage Rate
24. Shutdowns Scheduled Over Next 6 Months (Type. Date.and Duration of Eachi:

Refueling - December 15, 1981 - 12 Weeks

25. 4f Shut Down At End Of Report Period. Estimated Date of ',:srtup:
26. Units in Test Status (Prior to Commercial Operation s:

Forecast Achieved INITIA L CRITICALITY INITIA L ELECTRICITY COMMERCIA L OPER AT10N pc ;

=-

4 llNII S!HlDOWNS AND POWI R Hl:DuriloNs DOCKET No.

50-270 UNIT NA6tE Oconee Unit 2 llA IE 10-15-81

~

lit.I'OR I AlONill September, 1981 COMPLElElp uy J. A. Reavis lELEril0NE 704-373-8552

=_

s

i

!E 3

5'k IAcusec

[*,

Cause & Curreceive c,

N...

thic g

gg g

,j g 5 livent 3'E

&T Attion to d5 c2 5 ;f, c itepost u m' u EO Psevent Recursente F

{

U o

10-p 81-09-04 F

A CB MOTORX Power reduced to remove 2B2 reactor coolant pump (RCP) from service due to low oil level in Icwer motor bearing.

6 81-09-06 F

248.27 A

1 CB MOTORX Unit shutdown due to low oil level in two RCP motors.

2A2 & 2B2.

7 81-09-18 F

296.02 A

1 CB HTEXCil Tube leak in 2-B steam generarbr.

I 2

.I 4

l-l.nical Re. >nn :

hicihinl:

Eshibis G - Instinctions S. Sil.cilnicil A l'iguipinens I;ailine 11 spl.nn) i Al.niu.nl fin Preparation of Data ll.hlainten.iin e of Ics:

2 klanual Scram.

Ents) Shcels su l.icensec

  • C iteluchng
1. Automatic Ss s.un.

Event f(cpini ll.liHI File INilRI.G-Il Hes;nt.aiin) Resiai.sann

-l Othes i Explai il 01 til i I Opcs.sion is.uning.1 I henw I unnn.eison l'. Ailnnniss a.a sive 5

G Oper.arion.il I s eus llNpl.nni Ihhihis 1.Same Sousee l'8/Ill II Othes libel.oni

?

AVERAGE D ALLY L* NIT POWER LEVEL DCCKET NO.

50-u70 Oconee Unit 2 10-15-81 DATE COMPLETED BY J. A. Reavis TELEPHONE (70/d373-8552 3:og ty September, 1981 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY ?OWER LEVEL l'3the-Net) i3gw..,g3 3

835 247 I.,

t 836 440 IS 835 3

19 4

820

~~

20 i

5 559 6

497 y

3 3

9 l

10 25

~~

11 12

3 l

12

9

__?

20 l5 3;

16 i

r I

!NSTRL'CT1CNS Cn th:s fer- :t. list :he aer:ge f: 'y ;: it p;wer :e. e ;a ',1We..Se :,r e:e,,.:.,

,.,2 2 c. t.... : s e,

.e.esrest.vheie :.epw:::

b Ok r

l e

w w

MONTHLY REFUELING INFORMATION REUUEST 1.

Facility name:

Oconee Unit 2 2.

Scheduled next refueling shutdown: December, 1981 3.

Scheduled restart following refueling:

March, 1982 4.

Will refueling or resu=ption of operation thereafter require a technical specification change or other license a=endment?

Yes If yes, what will these be?

Technical Specification Revision If no, has reload design and core configuration been reviewed by Safety Review Co==1ttee regarding unreviewed safety questions?

NA If no, when is review scheduled? NA 5.

Scheduled date(s) for submitting proposed licensing action and supporting infornation: October. 1981 6.

I=portant licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).

7.

Number of fuel asse=blies (a) in the core:

177 (b) in the spent fuel pool:

542*

8.

Present licensed fuel pool capacity:

1312*

Size of requested or planned increase:

None 9.

Projected date of last refueling which can be acco==odated by present licenr.ed capacity:

DUKE POWER COMPANY Date:

October 15, 1981 Nabe of

Contact:

J. A. Reavis

  • Represents' total for the combined Unit 1 & 2 Spent Fuel Pool.

_ =.

?'

o t

a DOCKET NO: 50-270 UNIT: Oconee Unit 2 DATE:

10-15-81 i

NARRATIVE

SUMMARY

MONTH: September, 1981 4

Oconee 2 began the month at near rated power. Power was reduced on September 4 at 2222 to remove reactor coolant pump 2B2 from service because of a low oil level alana on the lower motor bearing.

I The unit was shutdown on September 6 at 2330 after indication of a low oil level in both the 2A2 and 2B2 RCP lower motor bearings. After inspection and correction of the problem the unit was returned to service on September 17 at 0746 and increased in power.

A tube leak in the 2"B" steam generator forced the unit from service on September 18 at 1559.. Repair of the leak continued the remainder of the month.

i l

+

e f

e

,y s

y e

p.

e

_a-

-te-

--1.-r m.

?

OPERATING DATA REPORT DOCKET NO.

50-287 DATE 10-15-81 COMPLETED BY J. A. Reavis TELEPHONE 7n/1 17 % R552 OPERATING STATUS

1. Unit Name:

oconee Unit 3 Notes

~~

2. Reporting Period:

Sep tettber, 1981 Year-to-date and cummulative capacity factors are calcu-

3. Licensed Thermal Power Olwe):

2568 lated using a weighted

4. Nameplate Rating (Gross MWe):

934 average for maximum 5.< Design Electrical Rating (Net MWe):

886

6. Maximum Dependsbie Capacity (Gross MWe):

899

7. Maximum Dependable Capacity (Net MWe):

860 S. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report. Give Reasons:

None None

9. Power Level To Which Restricted. If Any (Net MWe):
10. Reasons For Restrictions. If Any:

This Month Yr..to.Date Cumulative

11. Hours in Reporting Period 720.0 6,551.0 59,543.0
12. Number Of Hours Reactor Was Critical 692.5 4,701.8 43,104.0
13. Ractor Reserve Shutdown Hours
14. Hours Generator On.Line 683.9 4,628.1 42,107.1
15. Unit Reserve Shutdown Hours
16. Gross Thermal Energy Generated (MWH) 1,726,811 11,596,608-101,900,949 17 Gross Electrical Energy Generated (MWH) 586,670, 3,984,500 35,215,714 1:i. Net Electrical Energy Generated (MWH) 558,695 3,790,462 33,504,657
19. Unit Service Factor 95.0 70.7 70.7
20. Unit Availability Factor 95.0 70.7 70.7
21. Unit Capacity Factor (Using MDC Nett 90.2 67.3 65.2
22. Unit Capacity Factor (Using DER Net) 87.6 65.3 63.5
23. Unit Forced Outage Rate 5.0 3.7 15.7
24. Shutdowns Scheduled Over Next 6 Months (Type. Date.and Duration of Each :

None i

25. If Shur Down At End Of Report Period. Estimated Date of ".,tartup:

[

26. Units in Test Status (Prior to Commercial Operation):

Forecast Achieved i

INITIA L CRITICALITY f

INITIAL ELECTR2 CITY l

r COMMERCIAL OPER ATION i

m!7n l

4 s

llNil silll1 DOWNS ANI) PI)WIII Hiil UcIloNS DOCKET NO. 50-287 UNIT NAME 0conee Unit 3 DATE 10-15-81 September, 1981 COMPLET ED lly

.T. A. Reavis HLi'Olt i AlONill TELEI'llONE 704-373-8552 5E 5'd I.it ensec j r,,

Cause & Correceive No.

D.n c g,

3-g jgy liven g,7 g.y Atij,ni go jE d

55=

Hepuis n mU EU Peevent Recuarence H

{

U e

o 7

81-09-04 F

26.67 A

3 HA INSTRU Generator / reactor trip due to opera-tion of 86G generator. lockout relay.

8 81-09-05 F

9.47 A

3 CH VALVEX 3 FDW - 41 (main feedwater control valve) failed shut, due to a bad module in the ICS.

I 2

.I

l. l.ncnl Heason:

Meilnsil:

lixhibie G - Insieucilons S. S.hcilnicil A l'quipineni 1.nluie 11 spl.nn) i Alanual for Pseparation of Dana ll hl.sinten.ince us Tes 2 Alanual Sesani.

1:nts) Sliccis fin 1.icensee C.Helueling 1 Autoon.stie Sa.nn.

Event Report II.l:RIl'ils iNilRI.G-D Regulatin) Resisicnon l Oslies ll.xpl.iisil 0161) l' Opes.stos is.nning X l a neu I.saenin.sinin l' Ailtinsit>tsJilve 5

G Ogwsainnial I sens (l!spl.nni lishibit I. Same Source l'8/ /1) ll Othes (limplane)

.- ~.- -

r AVERAGE D AILY UNIT POWER LEVEL DCCKET NO. 50-287 Oconee Unit 3 10-15-81 DATE COMPLETED BY J. A. Reavis TELEPHONE (700 373-8552

.itONTH 1eptember, 1981 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (5the-Ner ISIWe-Net) 836 831 1.,

2 835 13 831 3

835 827 g9 4

286 829 20 5

833 6

595 833 824 834

,3 3

826 834

4 827 832 9

10 826 26 831 827 824 830 827 1,

23 i-831 835

,9 14 830 833 30 15 829

.JI is 828 i

INSTRUCTIONS Of1 th:1[Cft;":1. list :ne a'.er:ge j: gly *;,gt p;wer 'evet :n 'elWe. bet ic* e:c3,a.

^

  • .:...e2f tst Ahcie.-*.t pw:::

.ng 9,.. g;3,,g.t"-

~'"~~te'

-a' I

p) - g i

t MONTHLY REFUELING INFOTO!ATION REOUEST o

1.

Facility name:

Oconee Unit 3 2.-

Scheduled next refueling shutdown:

June, 1982 3.

Scheduled restart following refueling:

August, 1982 l

4.

Will refueling or resu=ption of operation thereafter require a technical specification chan5e or other license a=endment?

Yes If yes, what will these be?

Technical Specification Revision If no, has reload design and core con. iguration been reviewed by Safety Review Co=mittee regarding unreviewed safety questions? NA 1

If no, when is review scheduled?

NA 5.

Scheduled date(s) for submitting proposed licensing action and supporting inf o rma tion:

March, 1982 6.

I=portant licensing considerations (new or different design or supplier, unreviewed design or performance analysis methods, significant changes in design or new operating procedures).

7.

Nu=ber of fuel assemblies (a) in the core: 177 (b) in the spent fuel pool:

463 8.

Present licensed fuel pool capacity:

474 Size of requested or planned increase:

None 9.

Projected date of last refueling which can be acco==odated by present 4

licensed capacity:

i DUF2 PC'.'ER COMPA2Tf Date:

0ctober 15, 1981 Na$eofContact:

J. A. Reavis

DOCKET NO: 50-287 UNIT: Oconee Unit 3 DATE: 10-15-81 NARRATIVE

SUMMARY

MONTH: September, 1981 Initiation of the generator lockout relay (86G) resulted in a generator / reactor trip on September 4 at 0853. The unit returned to service on September 5 at 1133. At 1145 another reactor / generator trip occurred when a control problem caused the main feedwater valve (3 FDW-41) to fail closed when placed in the auto mode. At 2113 the generator was on line and increased in power. The unit ran at near rated power the remainder of the month.

e 1

J 6

I

=

4

+

,w---

-m,

+

.f.

J OCONEE NUCLEAR STATION Operating Status Report 1.

Personnel Exposure For the month of August, 3 individual (s) exceeded 10 percent of their allowable annual radiation dose limit with the highest dose being 1.620 rem, which represents approximately 13.5% of that person's allowable annual limit.

2.

The total station liquid release for August has been compared with the Technical Specifications annual value of 15 curies-the total release for August was less than 10 percent of this limit.

1 The total station gaseous release for August has been compared with the derived Technical Specifications annual value of 51,000' curies; the total release for August was less than 10 percent of this limit.

i r

4 i

e e

1 I

i L

e I

4-.

. ~..

.mv_,_e.-

s. r -

r.g.

w