l2 4

~-

nNIT mtE 2ndian Point t' nit No. 2 DATE April 5, 1977 o

S. D. Julias COMPIxTrD BY q

Performance General Supervisor Tele.#914-694-6000 O P E R A T I *3 c STATur Ext. 231 @ I.P.

1 I

1.

REPORTING PPRIOD:

770301 TunOUca 770411 I

744 l

CROSS nOURS 1*: RE90PTING PC'tIOD:

2.

CURRrN LY AU non!'ED POWrR Lr"EL m t 2758 rue-NET 864*

1.

POWER LEVEL TO WHICP RESTPICTM (IP ANY):

Ione

, me-NrT 4

PJFrhrr FOR REST).ICTIONS (IP A*TY)t CUMULATIVE **

TitIS MONTH YR-TO-DATE TO DATE

... 653.38 1896.31 15534.95 5.

HOURS REACTCR WAS CRITICAI..

0 0

0 6.

REAC-OR RESERVE SHUTDOw:: nouRS (s) 7.

nOURS crNr.u TOR ON-TINE

... 645.62 1865.81* 14958.14 0

0 0

s.

UNIT RrSERvE SnUTDOwN nouns (s>

s.

CROSS THE MAL PcwER crNERATEn (Mwu)

...l.721656 4931945 37266242 10.

CROSS rtrCTRICAL POWER cENERATED (xwn) 530240 1522720 11593536 n.

NET ELrctRICAL rOwr.R GrNrnArrD (run)

...507884 1457627 11038185 b

  • b 87.8 64.4 12.

REACTOP AVAIIABILITY FACTOR (1) 11.

rIAnT AvAIIAn!!.!TY rACTOR m 86.8 86.4 62.0 79.0 78.1 53.0 14 nts: CAPACITY FACTOR M) 1s.

rORCEn nuTAcr PATE (4) 0.82 6.69 7.87 16.

SPUTDOWUS SCltEDULED TO BFGIN IN NEXT fi MONTHS (STATE TYPE. CATE AND DUuTION Or rACuli Steam generator inspection outage (5 weeks) in April, 1977 i

1 17.

Ir FHUTDOWN AT r.f;D Or PrPORT DrRIOD, EFTIMTED DATC OF STARTUP 19.

PLANTS IN TEST STATUS (PRIOR TO CottMEDFIAL OPEPATION) REPORT THE rOLLOWINc3 DATE IAST DATE REASON FOR rGRTCAST PCUIEVED DIrrEPINCE INITIAL CRITICALITY INITIAL ELECTRICAL I*b*

PowrR GENrRA*IO'l COMMERCI AL OPEFATION N

(1) RrAC"OR AVAIIABILITY rAC"OR

  • POURS 9FAC+0R WAS CRITICAL x 100 GDOSS HOURS IN RI.PGRTING PERIOD (2) PIANT AVAILABILITY rACTOR = Pot:RS CFNFkATOR ON-LIMP N100 GkOSS HOU9S IN kEPObTING PEPIOD (3) P! ANT CAPACITY rACTOR = NET rfSCTRICAL POWER CFNFRATFD 4100 FIJRRTNTLY LICL!.50D FOWT R LP/EL x r:909S NOURS IN REPORTINt* DrRIOD (4) rORCED OUTAGE RATE = PORCED OUTACE nOURS X 100 HOURS GEt;EkATOR ON-LINE + FORCED OUTAGE HOURS (s) REACTOR RESrRVE SHUTDOWN HOURS
  • THr. DUPATION IN HOURS THAT THE REACTOR WAS REMOVED FROM SERVICE FOR ADMINISTRATIVE OR OTHER REASONS BUT WAS AVAIIABLE FOR OPERATION.

(6) UNIT RESERVE SHt1TDOWN HOURS = TUE DUPATION IN POURS T!!AT THE UNIT WAS Rr>tOVED rROat l

SERVICE FOR ECONort!C OR SI'tIIAR REASONS, BUT WAS AVAIIARIE FOR OPERATION.

00 g.. _ N U R

DO O

a

3.-

UNIT Indian' Point Unit No. 2 i

DATE April 5, 1977 COMPLETED BY S.

D.

Julias Performance General Supervisor Tele.#914-694-6000 DAILY PLANT POWER OUTPUT Ext. 231 @.I.P.

MONTH March, 1977 DAY AVERAGE DAILY MWe-net DAY AVERAGE DAILY MWe-net 1

823 21 823 2

827 22 841 3

839 23 829 4

803 24 833 5

640 25 833 6

638 26 834 7

637 27 831 8

637 28 833 9

706 29 833 10 827 30 837 11 464 31 828 12 0

13 0

14 0

15 82 16 788 17 825 18 830 19 840 20 835

.u..,,

Indian Point

+

UNIT NAME Unit No. 2 UNIT SIIUTDOWNS AND POWER REDUCTIONS DATE April 5, 1977 COMPLETED BY S.

D.

Julias REPORT MONTII March, 1977 TELEPIIONE 914-694-6000 Ext. 231 0 1.P.

METIIOD OF TYPE SIIUTTING DOWN F: FORCED DURATION TIIE REACTOR OR NO.

DATE S: SCHEDULED (HOURS)

REASON (1)

REDUCING POWER (2)

CORRECTIVE ACTIONS / COMMENTS

'i. A.

3/5/77 N.A.

M.A.

B: NI Cali-N.A.

In-core /ex-core nuclear inst, bration calibration test.

145 3/11/77 S

93.02 B

3 Repaired leak on the seal in-jection header downstream of the seal injection filters.

146 3/15/77 F

1.45 A: High S/G 3

None Level #22 S/G 147 3/15/77 F

3.92 A: High S/G 3

None Level #21 S/G

SUMMARY

Steam generator moisture (1) REASON (2) METHOD carryover test conducted at 100%

A: EQUIPMENT FAILURE (EXPLAIN) 1: MANUAL power.

Average carryover was B: MAINT. OR TEST 2: MANUAL SCRAM 0.162% with no significant dif-C: REFUELING 3: AUTOMATIC SCRAM forence between generators.

D: REGULATORY RESTRICTION 4: OTilER (EXPLAIN)

E: OPERATOR TRAINING AND LICENSE EXAMINATION F: ADMINISTRATIVE G: OPERATIONAL ERROR (EXPLAIN)

H: OTHER(EXPLAIN)

'4

-