ML20049J245

From kanterella
Jump to navigation Jump to search
Public Version of Revision 11 to Emergency Plan Implementing Procedures Index,Including Temporary Mod Requests J-6074 to Procedure Ei 1300.07 Re Technical Support Ctr Activation & T-6064 to Procedure Ei 1300-01
ML20049J245
Person / Time
Site: Davis Besse 
Issue date: 02/18/1982
From: Durdel R
TOLEDO EDISON CO.
To:
Shared Package
ML20049J206 List:
References
PROC-820218-01, NUDOCS 8203120304
Download: ML20049J245 (5)


Text

"

l.

~

.~

~...

7

-~/~"

'~-

a __.u _..li '

.2 :.

el i

i e

r r

THE TOLEDO EDISON COMPANY DAVIS-BESSE NUCLEAR POWER STATION w

EMERGDICY FLAN IMPL12iENTING PROCEDURES l

REVISION INDEX M

I a

PAGE REVISICN PROCEDURES REVISION TDTORARY MODIFICAT*' NS

'~

i, O

EI 1300.00 1

T-6014

.a II 1300.01 2

T-6064 EI 1300.02 1

T-6015 l

EI 1300.03 1

T-6059 EI 1300.04 1

T-6060 EI 1300.05 1

T-6061 EI 1300.06 2

/

EI 1300.07 1

T-6016 T-6074

.)

\\

EI 1300.08 2

T-5849, T-6041, T-6051 EI 1300.09 0

EI 1300.10 0

T-6017 u-EI 1300.11 0

T-6018 EI 1300.12 1

T-5850, T-5918 2

y ll 9

5 i

-)

Revision 11 d

February, 1982 2

e5ammm,- -. ______

Ok bbOMS go1

]

PDRADOCK05000g F

s

1

. _.m..u_.l.;

.m.m

- -. a -1

- mil J - ' - - =

RisUTloN orleines, R. oonsinie section H..d Action

%g

_ P,1. a.... M.- P,..

(

I V

OAVIS.BESSE NUCLEAR POWER STATION. UNIT 1 COPIES To BE MoOIPIED PoM IMMEDIATE IMPLEMENTATION Technical Support Center Technical Eng.

TEMPORARY MODIFICATION REQUEST Emergency Control Center (2) Station Supt.

E D s92s Nuclear Engineering Mgr.

Shift Supv.(2)

SECTION 1 PROCEDURE TITLE ANo NUMBER Technical Support Center Activation - EI 1300.07 REASON PoR CHANGE To incorporate TSC activation requirement and to provide a job iescription of the Onsite Assessment Manager.

k I

)

g CHANGE 1.

Revise Section 5.2 to state, "The TSC shall be activated at the Alert Emergency Classification level."

2.

Change " Nuclear Engineering Manager" in Section 5.4.8 to "Onsite Assessment Manager".

3.

Add a new Section 5.5, as attached.

4.

Renumber the remainder of the sections accordingly, i.e. Section 5.5, Technical Engineer, to 5.6; 5.6 to 5.7; 5.7 to 5.8, etc.

5.

Delete " technical engineering staff" from Section 5.7.1.

6.

Change Section 5.7.2 to 5.7.3 and add a new Section 5.7.2, which states "The Technical Engineering Staff, who are NOT assigned to other emergency functions, shall report directly to the TSC."

e IS PROCEDURE REVISloN REQUIRED Yes No if no, this modification is valid until

-A PREPARED BY

((

OATE Georee J. Reed / Ronald R. Du rdel APPROVED BY 2/12/82 DATE

^"" "' " (6. 0. u)%

o /, o /r ;,,

^'"

3d(Section.Y ed L* A 2/n/ex

-' "'NSU8MITTE a

DATE

' d RECoMME O O BY (SRB Chairman) s

/

DATE sf WMA SbY QA APPROVED BY (Manager of owealty Assurance) [

OATE

['

[

A)' #

APPROVED BY (Station Superintendent) f, DATE 1

w%

2 / / WPt

..m-

- - - ~ ~ - - - ~ ~

j

....,. ~ ~. -

~, ~

1

, c. g y ;c. g:g,,. g. q.j g J; czy A....

a a J.s,,

s..

. =....=.;

m.i_.. ~ -..~, w

/.

f

~

5.5 Onsite Assessment Manager 5.5.1 The primary Onsite Assessment Manager is the Nuclear Engineering Manager.

5.5.2 The alternate Onsite Assessment ! Laager is the Plant Nuclear Sys-tems Engineer.

5.5.3 The Onsite Assessment Manager, upon being informed that an Alert level emergency exists, shall proceed to the Technical Support Center (TSC).

5.5.4 The Onsite Assessment Manager's responsibilities and duties include, but are NOT limited to:

Directing the engineering assessment activities of the TSC.

a.

b.

Coordinating the engineering assessment activities of engineering support personnel from the NSSS vendor and the Architect Engineer, Ensuring that adequate mechanical, electrical, instrumentation c.

and control, and technical engineers are available to perform

,s,1 engineering assessment, as required.

. j,E d.

Ensuring that adequate support personnel are available to assist in records disposition, updating status board, and providing communications to the Control Room and Nuclear Regulatory Commission, as necessary.

Reporting to the Station Operations Manager and appraising him e.

of engineering assessment activities, equipment operation problems and any alterations in the normal lineup or operation of plant systems.

I r

e*

l-

.l v

1

-t.,__._..---_=

~,

i s

wee = - ww a.

r-w... w

.vM

,,.,;L~

e

  • ^

TRIBUTION Original, Responsible Section Head Action File Copy, Master File DAVIS BESSE NUCLEAR POWER STATION UNIT 1 l

b/

ytyve 5=7vS O

'*h?) E M (<2)

TEMPORARY MODIFICATION REQUEST E D 6926

$ ggq 4', 9 $4vy.hs.y.

%J w

4

/

SECTION 1 Q

.,) cn-55 /Y a8/

REASON FOR CHANGE 4 c/u

' - u<g mam_ /ud ekk l sp q a d w

a-4

+ w:ll - J + ; ~ w a=:o a cls cl % % s N ck N cea se&C8 ve Sk% k w y; &c.

elm G r i.sae d, d r w fus

,ygesg-y pudx( /aweoer clanR & ts ab en n eeene

,a u. A w s A 4 4 %

sh

& a s yy /ml & y a.d 't' e%'x

.4 l

4c,

_pa k~s.Ls ygelue'&

,. CHANGE gg w'

es4 D

W I

W C

y

w% uck pu +b f -pp 2 3 g E I m ot.

Jos Tdd lJ, a Js, e A

Ak,

&,<dg% a n py$k h %

  • s~ d "

s%;

k p n.

T k s 1% L - u o.

uvud.

isco.cl 4L e,

e.a s

44 4A.

su. L%

IS PROCEDURE REVISION REQUIRED y,

.... c A. E D..

D.,E APPROVED DY

[

[

_' j/

DATE

/ ' --

. <. >..<*w APPROVED BY

_ ckB

<a /.7

-r -,

DATE

._,T,ED.y g, g g;p,

.A,.

J RECOMMENDEp)bY (SRB Chairrnen)

[2////M-DATE v

A 9 ca-eyt1p-QA APPROVED BY (Meneger of QueHty Assurance)/

DATE

/

[

/ APPROVED BY (Station Superintendent)

DATE

) p.9 N y3J W u ~-- r 2-/k/*tt-a

ldt.

a

,h~

  • f, J

, e.

m ws : ;

. = = = - -

e i

I l

25 El 1300.01.0 k

(s ?,_

TABLE 1

=

s FIRE Emergency Condition Indication (s)

Classification Uncontrolled fire NOT 1.

Any fire at the Station Unusual Event involving a safety that requires offsite (EI 1300.02) system, but requiring support offsite support Uncontrolled fire 1.

Any fire at the Station Alert potentially affecting that requires offsite (EI 1300.03) safety systems and support requiring offsite AND support 2.

Has the potential to damage or degrade a safety system Fire resulting in 1.

Observation of a major Site Emergency the loss of redundant fire that defeats the (EI 1300.04) safety system trains capability of redundant or functions safety system trains (which 2

includes 30th trains) or functions G

C (ai i

t