Advises That Proposed Inservice Insp Interval Is 790401 to 820601,based on Review of Previous Submittals.Addl Insp Relief Requests Expected within 30 Days.Requests Should Deal w/pressure-bearing Components & Sys Pressure Tests Only
ML20049J060
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 02/17/1982
From: Crutchfield D
Office of Nuclear Reactor Regulation
To: Vandewalle D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
LSO5-82-02-072, LSO5-82-2-72, NUDOCS 8203110513
Download: ML20049J060 (4)


Text

i

\\[i 4f7

.Ic UNITED STATES g

!, pf, (

g NUCLEAR REGULATORY COMMLSSION

,,,K l

WASHINGTO N, D. C. 20555 e

o #*6 g

%' v /

February 17, 1982 Docket No. 50-155 e

LS05-82-02-072

/

3 O

&g %

i C

Mr. David J. VandeWalle Z

Nuclear Licensing Administrator 2

.g Consumers Power Company 1945 W. Parnall Road Jackson, Michigan 49201 N

'l~

j m

3

Dear Mr. VandeWalle:

/

SUBJECT:

BIG ROCK POINT - INSERVICE INSPECTION (A-01)

The NRC staff has initiated a substantial effort to bring current its approvals of inservice inspection relief requests. The purpose'of this letter is to ensure that the information we are supplying to our contractors for review is current and reflects the latest requirements for your facility.

For Big Rock Point our review will include your following previous submittals:

Letter from Sewell to NRC, dated May 19, 1976, response to NRC guidance letter; Letter from Skibitsky to Ziemann (NRC), dated April 7,1978, requested extension of internal inspection; j,

Letter from Bixel to Davis (NRC), dated July 27, 1978, Technical Specification change request; Letter from Bixel to Ziemann (NRC), dated December 22, 1978, ISI plan and relief request; Letter from Bixel to Ziemann (NP.C), dated July 25, 1979, change in code basis; Letter from Consumers Power Company. to NRC, dated October 14, 1979, relief request; Letter from Withrow to Crutchfield (NRC), dated October -15,1980, code requirements; Letter from Hoffman to Crutchfield (NRC), dated November 17, 1980, relief request revision; Letter from Withrow to Keppler (NRC), April 13, 1981, special report.

i.

  • r 8203110513 820217 FDR ADOCK 05000155 O

PDR i

.9 d

~ _ _

9 h

fir. David J. VandeWalle Febr*uary 17, 1982 r

Any earlier su'nittals on the subject of the IS! Program will be considered 4

obsolete. However, please review the list of submittals above to ensure that it is complete. 1.1kewise, if there are any additional requests for relief that should be considered for the proposed inspection interval, please submit these requests,within 30 days.

Based dn these submittals, the proposed inspection interval for this unit is April 1,1979 to June 1,198?. We will be conducting the review against the requirenents of the 1974 edition of Section XI of the ASME Code up to and i

including the S-75 Addenda and the S-78 Adder.da to the 1977 edition.

Plote that such requests should deal with only the inservice inspection of pressure-bharing conponents including supports and with systen pressure tests. The inservice testing of pumps and valves is being treated separately and you will receive information regarding it by separate correspondence.

l Your requests should include both exempted conponents under the terns of the code as well as relief from the requirenents of the code in accordance with Paragraph q of 10 CFR 50.55a. Also please advise when you are using later code versions than the S-75 Addenda to the 1974 Edition or the S-78 Adder.da to the 1978 Edition Addenda (per Iten (g)(4)(iv) of 10 CFR 50.55a) for certain exaninations, particularly how you are meeting "all related require-l c'ents" from the same version.

Because your previous subnittals generally seen to follow the appropriate guidelines, we are proceeding with the review. Early in that review, we may be contacting you for additional information. To expedite the review, please advise your assigned project nanager, Richard Emch, verbally as soon as possible (within 10 days) as to submittals we should be reviewing or other requests for relief that are forthconing.

i The reporting and/or recordkeeping requirements contained in this letter af fect fewer than ten respondents; therefore, OMB clearance is not required I

under Public Law 96-51).

DISTRIBUTION: HSmith Sincerely, C_ Docket D 0 ELD ORB #5 RF OI&E ORIGINAL SIGNED BY NSIC ACRS (10)

_ DENNIS M. CRUTCHFIELD LPDR RScholl Dennis M. Crutchfield, Chief

+

NRC PDR Operating Reactors Branch #5 DCrutchfiel.1 Division of Licensing REmch cc:

See next page f

n CN RE,m,ch,;,d,gaugu,,,,

,ie,ld. ag.a........

aunnan..

u m.s o,,.

DC,r G L,,,,,,,s,,,,,,,,,,&,Qg,,,,g

, aumre>

........1.....M....S../..b.

..... '../. 8. 2....

.....g /... 8. 2.......,. g.,, g,......,

one)

' ' me ronu sis oo-soi mcu oao OFFICIAL RECORD COPY usam mi-m..eo :

Mr. David J. VandeWalle February 17, 1982 Any earlier submittals on the subject of the ISI Program will be considered obsolete. However, please review the list of submittals above to ensure that it is complete. Likewise, if there are any additional requests for relief that should be considered for the proposed inspection interval, please submit these requests within 30 days.

Based on these submittals, the proposed inspection interval for this unit is April 1,1979 to June 1,1982. We will be conducting the review against the requirements of the 1974 edition of Section XI of the ASME Code up to and including the S-75 Addenda and the S-78 Addenda to the 1977 edition.

Note that such requests should deal with only the inservice inspection of pressure-bearing components including supports and with system pressure tests. The inservice testing of pumps and valves is being treated separately and you will receive information regarding it by separate correspondence.

Your requests should include both exempted components under the terms of the code as well as relief from the requirements of the code in accordance with Paragraph g of 10 CFR 50.55a. Also please advise when you are using later code versions than the S-75 Addenda to the 1974 Edition or the S-78 Addenda to the 1978 Edition Addenda (per Item (g)(4)(iv) of 10 CFR 50.55a) for certain examinations, particularly how you are meeting "all related require-ments" from the same version.

Because your previous submittals generally seem to follow the appropriate -

guidelines, we are proceeding with the review. Early in that review, we may be contacting you for additional information. To expedite the review, please advise your assigned project manager, Richard Emch, verbally as soon as possible (within 10 days) as to submittals we should be reviewing or other requests for relief that are forthcoming.

The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under Public Law 96-511.

Sincerely, yl Dennis M. Crutchfield, ie Operating Reactors Branch #5 Division of Licensing l

cc:

See next page 1

l

i'

\\

Mr. David J. VandeWalle February 17, 1982 F

cc:

Mr. Paul A. Perry, Secretary V. S. Environmental Protection Consumers Power Company Agency 212 West Michigan Avenue Federal Activities Branch Jackson, Michigan 49201 Region V Office ATTN:

Regional Radiation Representati'le Judd L. Bacon, Esquire 230 South Dearborn Street Consumers Power Company Chicago, Illinois 60604 212 West Michigan Avenue Jackson, Michigan 49201 Peter B. Bloch, Chairman Atomic Safety and Licensing Board Joseph Gallo, Esquire U. S. Nuclear Regulatory Commission Isham, Lincoln & Beale Washington, D. C.

20555 1120 Connecticut Avenue Room 325 Dr. Oscar H. Paris i

Washington, D. C.

20036 Atomic Safety and Licensing Board U. S. Nuclear Regulatory Commission l

Peter W. Steketee, Esquire Washington, D. C.

20555 505 Peoples Building Grand Rapids, Michigan 49503 Mr. Frederick J. Shon Atomic Safety and Licensing Board Alan S. Rosenthal, Esq., Chairman U. S. Nuclear Regulatory Commission Atomic Safety &- Licensing Appeal Board Washington, D. C.

20555-C'. S. Nuclear Regulatory Commission Washington, D. C.

20555 Big Rock Point Nuclear Power Plant ATTN: Mr. C. J. Hartman Mr. John O'Neill, II Plant Superintendent Route 2, Box 44 Charlevoix, Michigan 49720 Maple City, Michigan 49664 Christa-Maria Charlevoix Public Library Route 2, Box 108C 107 Clinton Street Charlevoix, Michigan 49720 Charlevoix, Michigan William J. Scanlon, Esquire Chairman 2034 Pauline Boulevard County Board of Supervisors Ann Arbor, Michigan 48103 Charlevoix County Charlevoix, Michigan 49720 Resident Inspector Big Rock Point Plant Office of the Governor (2) c/o U.S. NRC Room 1 - Capitol Building RR #3, Box 600 Lansing, Michigan 48913 Charlevoix, Michigan 49720 Herbert Semmel Mr. Jim E. Mills Counsel for Christa Maria, et al.

Route 2, Box 108C Urban Law Institute Charlevoix, Michigan 49720 Antioch School of Law 263316th Street, NW Washington, D. C.

20460 t

t

i Mr. David J. VandeWalle 4

February 17, 1982 CC; Dr. John H. Buck Atomic Safety and Licensing Appeal Board U. S. Nuclear Regulatory Commission Washington, D. C.

20555 Ms. JoAnn Bier 204 Clinton Street Charlevoix, Michigan 49720 Thomas S. Moore Atomic Safety and Licensing Appeal Board j

U. S. Nuclear Regulatory Commission Washington, D. C.

20555 James G. Keppler, Regional Administrator Nuclear Regulatory Commission, Region III Office of Inspection and Enforcement 799 Roosevelt Road Glen Ellyn, Illinois 60137

  • e e

o e

h e

,,