hid,hw.tbj THE TEXAS A&M UNIVERSITY SYSTEM.

r ur f

TEXAS TRANSPORTATION INSTITUTE COLLEGE STADON TEXA8 Mets ramspoer oeterms enoamu gm my May 29, 1981 Mrs. Mitzte Solberg Emergency Preparedness Development Branch U.S. Nuclear Regulatory Comission Washington, D.C.

20555

Dear Mrs. Solberg:

i Enclosed is the review of the Hatch ETE submitted May 8,1981. Th'e overall rating was adequate with only one minor deficiency to note.

Reference was made _ x.

to consultation with state and local officials, but no indication is made to their having reviewed and commented on the report.

=

Sincerely, f

-A Thomas Urbanik II Assistant Research Engineer TU:Jem Enclosure cc Art Desrusier Battelle PNL i

P. O. Box 999 Richland, WA 99352 I

2 i

0 h!8is8MJ888831

"*""o" a""ac~ ~o "=o~r~r I

F PDR 2__

_._ _ _ _.. - m.,

l' EVALUATION OF EVACUATION TIME ESTIMATE Hatch Item Excel.

Adeq.

Poor None I.

Introduction A. Maps X

[

B. Assumptions X

C. Methodology X

f II.

Demand Estimation A. Permanent Residents X

B. Transtent Populations X

C. Special Facility Population X

D. EPZ Sub-areas X

III. Traffic Capacity A. Evacuation Roadway Network X

B. Roadway Segment Characteristics X

IV. Analysis i A. Report Format X

l B. Methodology X

V.

Other Requirements X

VI.

Overall X

Revised 5-1-81 mm_ e. c = v ar:2_T-_r_ _L T------

~

~~

~~

'