- _ _ _ _ _ _
.D' ISTRIBUTION:
/
Docket File 70-1151 r.
e *+PDR-NMSS rf FCUP rf -
FEB 101982 GHBidinger(2)
LTyson WTCrow JBlaylock RErickson DOCKET N0:
70-1151 JRobertson Region II APPLICANT: Westinghouse Electric Company (W)
FACILITY:
Columbia, South Carolina
SUBJECT:
REVIEW OF NtENEf1ENT APPLICATION DATED FEBRUARY 9,1982, CYLINDERS WITHOUT VALVE TO AUTHORIZE MOVE? TENT OF 13 UF6 COVERS - 07001151020S I.
Background
License Condition 36 of SNM-1107 requires that loaded UF6 cylinders have valve covers in place during movement.
W recently received thirteen (13) cylinders which do not provide Tor valve covers.
W_
requests authorization to move these cylinders from an onsite storage pad to the vaporizers inside the Manufacturing Building.
II. Discussion If authorized, W would provide special training in emergency actions to the transfer equipment operator and a supervisory representative who would accompany the cylinder movement.
In the event that a valve were damaged during movement, radiological consequences should be minimal because (a) the cylinders have a slightly negative pressure at ambient temperatures, (b) the UF6 is a solid at ambient temperatures, and (c) the supervisory representative can initiate prompt emergency au.lon, if needed.
III.
Conclusion The proposed activity should have no adverse effect on the public health and safety or on the environment. Approval of the application is recommended.
Originc.1 Cigned by Gocrco m EidiECT G. H. Bidinger Uranium Process Licensing Section Uranium Fuel Licensing Branch Division of Fuel Cycle and Ori k ' -
ned En Material Safety, HMSS C
E=A Ukron Approved by:
U W. T. Crow. Section 1.eader s
...FcuP..g9..
...FEUE..h..
..EffLg,....
o"'">
.GHBidinger.;ad..LTys9n....
....@. Urn.c....
B203o3oo95 e2021o cAu )
PDR ADOCK 07001151
""/*d /"82 2/ /o /82 2
"/1,0/"82 2
C PDR
~;c rowu xe no no,nacu o:40 OFFICIAL RECORD COPY
' " '