o 1
NEW YORK POWER AUTHORITY JP.MES A. FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JANUARY 1992 - JUNE 1992
' Revised Report TABLE 3A SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SHIPPE'3 0FFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel) 6-month Period Est. Total
- 1. Type of waste Unit class A class a class C Error %
- a. Spent resins, filter sludges, m'
6.73E+01 9.67E+00 0.00E+00 evaporator bottoms, etc.
Ci 9.81E+02 5.12E+02 0.00E+00 2.50E+01
- b. Dry compressible waste, m'
9.12E+01 0.00E+00 C.00E+00 contaminated equip, etc.
C1 4.84E+00 0.00E+00 0.00E+00 2.50E+01
- c. Irradiated components, control m'
O.00E+00 0.00E+00 0.00E+00 F/A rods, etc.
Ci 0.00E+00 0.00E+00 0.00E+00 N/A
- d. Others(describe) m 0.00E+00 0.00E+00 0.00E+00 N/A s
Ci 0.00E+00 0.00E+00 0.00E+00
.N/A
- 2. E:timate of major nuclide composition (by type of waste)
- a. Spent resins, filter sludges, evaporator bottoms, etc.
Isotope Percent curies Isotope Percent curies Iron-55 3.68E+01 5.49E+02 E
cesinm-134 9.59E-01 1.43E+01 M
Zinc-65 3.6BE+01 5.49E+02 M
Chromium-51 9.24E-01 1.38E+01 E
Cobalt-60 1.40E+01 2.08E+02 M
Cobalt-58 6.54E-01 9.76E+00 E
Manganese-54 7.75E+00 1.16E+02 M
Nickel-63 3.18E-01 4.74E+00 E
Cesium-137 1.41E+00 2.10E+01 M
Iron-59 2.72E-01 4.07E+00 E
- b. Dry compressible waste, contaminated equip, etc.
Isotope Percent Curies-Isotope Percent Curies Zinc-65 6.32E+01 3.06E+00 E
cesium-137 2.38E+00 1.15E-01 E
Iron-55 1.44E+01 6.97E-01 E
Carbon-14 4.77E-01 2.31E-02 E
Cobalt-60 1.35E+01 6.55E-01 E
Nickel-63 1.61E-01 7.80E-03 E
Manganese-54 5.81E+00 2.81E-01 E
- c. Irradiated components, control rods, etc.
i None
- 4. Others None (E - Estimate M-Measured) 9308130121 930722 E
i PDR ADOCK 05000333 i2 R
PDR g
i NEW YORK POWER AUTHORITY
~
JAMES A.
FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JANUARY 1992 - JUNE 1992
' Revised Report TABLE 3A SOLID WASTE AND IRRADIATED FUEL SHIPMENTS
- 3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination 26 Truck
- SEG, Inc.
Oak Ridge, Tn 4
Truck
- Alaron Corp.
Wampum, Pa.
- - Volume Reduction Facility 17 Truck Barnwell, S.C.
D. IRRADIATED FUEL SHIPMENTS (Disposition)
Number of Shipments Mode of Transportation Destination None N/A N/A r
i 9
?
4 NEW YORK POWER AUTHORITY JAMES A.
FITZPATRICK NUCLEAR POWER PLANT EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT JANUARY 1992 - JUNE 1992
' Revised Report TABLE 3B SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A.
NRC CLASS B SOURCE OF PROCESSING CONTAINER TYPE OF NUMBER OF WASTE EMPLOYED VOLUME CONTAINER CONTAINERS.
Spent Resin Dewatered 170.8 ft' HIC 2
Solidification Agent:
None B.
NRC CLASS A SOURCE OF PROCESSING CONTAINER TYPE OF NUMBER OF WASTE EMPLOYED VOLUME CONTAINER CONTAINERS Spent Resin &
Filter Media Dewatered 18.8 ft' STC 21 Spent Resin &
8 Filter Media Dewatered 170.8 ft HIC 3
Dry Compressible Waste (DAW)
Non-Compacted 177.5 ft3 STC 1
Dry Compressible Waste (DAW)
Non-Compacted 180.1 ft' STC 1
Spent Resin Dewatered 205.8 ft' HIC 2
Filter Media Dewatered 205.8 ft' HIC 5
Solidification Agent:
None HIC -
High Integrity Container STC -
Strong Tight Container Information provided to comply with JAFNPP 7echnical Specification.,
2..
ade.1.tr.ti.. co tra.
u!1R1do ive Effluent Release Report
. e.5 emi