ML20046C880

From kanterella
Jump to navigation Jump to search
Revs to 1993 EP Exercise Manual
ML20046C880
Person / Time
Site: Fort Calhoun 
Issue date: 06/21/1993
From:
OMAHA PUBLIC POWER DISTRICT
To:
Shared Package
ML20046C878 List:
References
NUDOCS 9308120354
Download: ML20046C880 (36)


Text

4 I

Change _ Summary to the 1993 Omaha Public Power District Fort Calhoun Station Emergency Preparedness Exercise Manual:

1.

On page 1-3 the_ FEMA Exit Interview has been added to take place on June 30, 1993.

2.

On page 1-3 the FEMA Public Meeting has been change from July 2,

1993 to June 30, 1993.

3.

On page 3-5 first paragraph fourth sentence has been changed to read " Winds are expected to shift from the south".

4.

Pages 5-45 though 5-48 have been added to provided data for onsite field team instrument readings. These additional pages provide raw data for OPPD Technicians and can be used to calculate participate, iodine, and smear activities.

5.

Page 7-3 bottom paragraph, third sentence has been revised to

+

read "... are expected to shift from the south".

6.

Pages 7-25 though 7-38 have been revised to include a column for smear activity in dpm/100cm2 for Fort Calhoun Field Team Equipment.

This column is for controller reference only.

7.

Pages 7-40 though 7-53 have been revised to include additional columns of RO-2 Dose Rates at 3 inches, 3 feet and 5 feet with beta windows open and closed.

These dose rates will provide data to satisfy Nebraska Field Team procedures.

Change Instructions:

1.

Remove page 1-3 and insert new page 1-3 dated 6/2/93.

2.

Remove page 3-5 and insert new page 3-5 dated 6/2/93.

3.

Insert new pages 5-45 though 5-48.

4.

Remove page 7-3 and insert new page 7-3 dated 6/2/93.

5.

Remove pages 7-25 though 7-38 and insert new pages 7-25 though 7-38 dated 6/8/36.

6.

Remove pages 7-40 though 7-53 and insert new pages 7-40 though 7-53 dated 6/9/93.

9308120354 930611 PDR ADDCK 05000285 F

PDR

CONDUCT of EXERCISE SCHEDUIE Of EVENTS (cont)

Event Attendees Time Location Jun 21, Mon Participant Briefing Exercise Participana 1230-1400 Energy Plaza Jun 22. Tue Controller / Evaluator Training CtirfEvala (All) "*

0800-1000 FCS Training Center Auditorium Scenario Briefing and WalkTnrough Ctirs/Evals (All) 1030-1630 FCS Training Center Auddorium Jun 23, Wed Participant Briefing Exercise Participants (FCS) 0800-1000 FCS Training Center Auditorium Participant Briefing Exercise Participants (FCS) 1000-1200 FCS Training Center Auditorium Participant Briefing Exercise Participants (FCS) 1230-1430 FCS Training Center Auditorium Jun 24, Thu Jun 25, Fri Ctir/ Eval Makeup and Review Ctirs'Evals (as needed) 1000-1200 FCS Training Center Auditorium Scenado Final Review EP, Ctirs (As Needed)

As Needed FCS Jun 26, Sat Jun 27, Sun Jun 28, Mon NRC Entrance

. NRC, EP OPPD Management 1130-1200 FCS NRC GI T Training NRC 1230-1330 FCS NRC Scenario Briefing NRC,EP 1500-1630 FCS Admin. Bldg., Visiting Inspectors Room NRC Walkdown of ERFs and Plant NRC,EP As Needed FCS, EOF Jun 29 Tue Exercise (Plume Phase)

OPPD Facility Critiques Participants (All), Ctirs/Evals Post Exercise ERFs Jun 30, Wed Federal Field Exercise, Day i NRC/ FEMA / Selected Participants 0800-1600 EOF. EOCs Key Participant / Key Eval Critique Key Participana, All Ctirs/Evals 0800-1100 FCS Training Center Auddorium Develop Licensee Critique Lead Ct!rvEvals 1100-1600 FCS Admin Bldg. Conf. Room 2F FEMA Exit Interview OPPD, FEM A, State / local 0900-1030 Council Bluffs Post Office Participants FEMA Public Meeting NRC, OPPD Management, FEMA 1300-1430 Council Bluffs Post Office Jul 1, Thu Federal Field Exercise, Day 2 NRC/ FEM A/ Selected Participants 0800-1600 EOF, EOCs Jul 2. Fri OPPD Management Cnuque OPPD Management, EP 0700-0830 EOF Conference Room licenace Presents Cntique to NRC OPPD Managernent, NRC 0845-0915 EOF Confen:nce Room NRC Critique and Exit OPPD Management. NRC 0930 1015 EOF Conference Room A BBREVI ATION 5 CTLR:

Controller EVAL:

Evaluator NE:

Nebranta EOF:

Emergency Operations Facility FCS:

Fort Calhoun Station NRC:

Nuclear Regulatory Commission EP:

Emergency Planning GET:

General Employee Training OPPD:

Omaha Public Power District EPZ:

Emergency Planning Zone IA:

lowa QA:

Quality Assurance ERF:

Emergency Response Facility IPZ:

Ingestion Pathway Zone TBD:

To Be Determined Note *:

Controllers who previously attented the two-hour Controller training for the dress ca66 3wAnuA1.tSCntDutE.wPs 1-3 6/2/93

~

SCENARIO MESSAGES CONTROLLER MESSAGES - CR/TSC/OSC/ EOF (cont).

TO:

Key Players NUMBER:

1 (Cont)

FROM:

Initial Conditions (All Facility Lead TIME:

0600 Controllers )

T-00:30 TYPE:

Handout Page 3 of 3 DRILL PURPOSE ONLY DO NOT initiate actions affecting normal plant operations.

P Meteorological:

Clear start to the day with possible late morning clouds. Temperatures expected from a low of 65*F to a high of 85'F. Winds are expected to be light from the east increasing in intensity to 10 mph by late morning. A weak cold front is expected to pass through the area late this morning. Winds are expected to shift imm the south. A 30% chance for precipitation is forecast for the late morning. Skies should clear again in the afternoon.

The grid is in a high demand-low reserve situation. Nebraska City is out of service. North Omaha is at 50% capacity. Any reduction in the output from FCS, and OPPD will have to start shedding customers.

s I

ca662nExERCISE\\ MESSAGES.WP5 3-5 6/2/93

4 5

1 of 4 ONSITE FIELD TEAM INSTRUMENT READINGS SECTOR P ESP-2 Inntrurneed Readings RSOS Frinker / IIP-260 Readings TIME smear pernculaw Icdine Expoeurs Rate smeer pernculais feet epm)

(act epm)

(met opm)

(mR/hr)

(netepm)

(net epm) 6 00 as ned as read as read as read as read as ned 6:15 as read as read u read as read as nad as read 6:30 as read as read as read as read as read as read 6A5 as reed as nad as read as read as read as read 7:00 as read as read as read as read as read as read 3

7:15 na read as read as read as read as read as read 7:30 as read as read as read as read as read as read 7:45 as ned as read as read as read as read as read 8:00 as read as na.!

as read as read as read a read 8:15 as read as read as read as read as read a read 8:30 as read as read as remi as read as read as read 8:45 as read as read as read as read as read as read 9.00 as read u read as read as read as read as read 9:15 as read as read as read as read as read as read 9:30 as read as read as read as read as read as stad 9AS as read as read as need as read as read as read 10:00 as read as read as read as read as read as read 10:15 2.84E+ 02 as read as read 1.94E+ 02 2.84E+02 as read 10:30 7.05E+02 as read es read 2.94E+02 7.05E+02 as read 10:45 1.26E+03 as read as read 4.14E + 02 1.26E+ 03 as read 11:00 1.77E+03 as read as read 3.89E + 02 1.77E+ 03 as ned 11:15 2.20E+03 as read as read 3.02E+02 2.20E+03 as read 11:30 2.57E+03 es read as read 1.00E+ 00 2.57E+ 03 as read 11:45 2.66E +03 as read as read as read 2.66E+03 as nad 12:00 2.73 E+03 na read as read as read 2.73E+ 03 na read 12:15 2.79E t03 as read asnad as reed 2.79E+ 03 na read 12:30 2.83E+ 03 as read as read as read 2.83E+ 03 as read 12:45 2.86E+03 as read as read as read 2.86E+ 03 as ned 13:00 2.87E+03 as read as read as read 2.87E +03 as read 13:15 2.87E+03 as read as read as read 2.87E+03 as read 13:30 2.87E+03 as read as read as read 2.87E+ 03 as read 13:45 2.87E+ 03 as read as read as read 2.87h : 03 as read 14 00 2 87E+03 as read u read as ned 2 87E+0').

as read i

i i

1 l

i j

i i

1 I

I EXERCISE \\ONFC1.XLS 545 Rev 6/8/93 i

'1 n

4

2 of d ONSITE FIELD TEAM INSTRUMENT READINGS

  • I SECTOR B 13P-2 Instrument Readmgs RSO5 Frisker / IIP-260 Readmgo TIME emear particulate ladine Exposure Rate ament panaculate (net epm)

(net epm)

(net dpm)

(mR/hr)

(net crm)

(net epm) 6:00 as read as read as nad as read as read as read 6:15 es read as read as read as read u read as read 6.30 na read as read as ned as read as read u read 6:45 as read as reed as read as ned as read as read 7:00 asread u read as read as read as read as read 7.15 as read as read as reed as read as rest as read 7:30 as read as read as read as read as read as read 7.45 as read as ned as read as read as read as read 8:00 as read as read as read as reed as ned as read 8:15 as read en read as read as nad as ned as read 8:30 as read as reed as read as read as read u read 8:45 as read u read u read as read as read as read 9:00 as read as ned as read as read as read as read 9:15 as remi as read as read as read as read as read 9:30 as read as read as read as read as read as read 9:45 as read as read as read as read as read as nad 10:00 as read as read as read as ned as read as read 10:15 as read as read as read as read as read as read 10:30 as read as read as read as nad as read as read 10:45 as read as read as read as read as read u read 11:00 as read as read as read as read as read as read 11:15 as read as read as read es ned as read as read 11:30 as read as read as read as read as read as read 11:45

3. doe + 02 as read u read 2.23E+ 02 3.06E+02 m read 12:00 5.64E+ 02 as reed u read 1.92E+ 02 5.64E+ 02
a. read 12:15 7.81E + 02 as read merad 1.55E+02 7.81E+02 as reed 12:30 9.65E + 02 as read as read 1.26E+ 02 9.65E+02 es read 12:45 1.09E+03 as read as read 8.74E+ 01 1.09E+ 03 asseed 13:00 1.14E + 03 as read u read 3.21E+ 01 1.14E+ 03 as read 13:15 1.16E+ 03 as read as read 9.87E+ 00 3.16E+03 as read 13:30 1.16E+ 03 as read as read 4.90E+00 1.16E+ 03 as read 13:45 1.17E+ 03 na read as ned 3.26E+ 00 1.17E+ 03 es read 14 00 1.17E + 03 as remi es read 2.28E + 00 1.17E+ 03 es ned l

1 1

I EXERCISE \\0NFC2.XLS 5-46 Rev. 6/8/93 i

i 3 of 4 ONSITE FIELD TEAM INSTRUMENT READINGS SECTOR Q, R, A ESP-2 ladrumerd Readman RSO5 Frisher / IIP-260 Readmga TIME smear partwulate lodme -

Exposure Rate smear pastzulate (net erm)

(netcom)

(net dem)

(mRStr)

(net epm)

(net com) 6:00 as nad as read as read as read as read as read 6:15 as read as ned as read as read as read as read I

6:30 as read ra read as read as read as reed as read 6:45 as read es read u read as read as nad as read 7:00 as read as read as read as read as read as read 7:15 as ned as read as read as read as read as read 7:30 as r2 as read as read as read as read as read 7:45 as read as ned as read as ned as read as read 8:00 as reed m read as read as read as read as read 5:35 as read as read as read as read as read as send 8:30 as read as rund as stad as read as read as read 8:45 as read as ned as read assend as read as read 9:00 as read as read as read as read as read as nad 9:15 as read as read as read as read as read as read 9.30 as read as read as read as read as read as read

f 9
45 as read as read as read as read as read as read 10:00 as read as read as read as read as read u read 10:15 as reed as read as read as read as nad as read 10:30 as read as read as read as read as ned as read 10:45 as read as read as ned as ned na read as read 11:00 as read as read as read as read as read as read 11:15 as read as read as read as read as read as read 11:30 2.91E+02 as read as read 2.15E+ 02 2.91E +02 as read

!!:45 5.36E+02 as nad as read 2.01E+ 02 5.36E+ 02 as read 12:00 5.87E + 02 as read as read 1.73 E+ 02 5.87E+ 02 as read 12:13 6.31E+02 as read as read 6.21E+01 6.31E+ 02 as read I

12:30 6.68E+ 02 as read as read 1.26E+ 01 6.68E+ 02 as read 12:45 6 93E+02 as read as read 8.74E+ 00 6.93E+02 asreed 13:00 7.03E+ 02 as read as read 3.21E+ 00 7.03E+ 02 as read 13:15 7.06E+ 02 as read as read 9.87E-01 7.06E +02 as read 15:30 7.07E+ 02 as read as read 4.90E-01 7.07E + 02 as read 13:45 7.08E + 02 na read as read 3.26E 01 7.08E+ 02 as read 14 00 7.00E + 02 as read as read 2.28F 01 7.09E+ 02 as read

?

5 l

)

i i

I EXERCISE \\ONFC3.XI3 5-47 Rev. 6/8/93

4 of 4 t

ONSITE FIELD TEAM INSTRUMENT READINGS ALL OTIIER SECTORS F3P-2 Indrument Readings RSOS Frisker / IIP-260 Readings TIME smear particulate ladins Exposure Rats amear particulate (netcrm)

(net com)

(ner dem)

(mR%r)

(net com)

(net epm) 6:00 as read as read as read as ned as read as ned 6.15 as read as read as ned as read as read as ned 6:30 as read as read as read as read as read as read 6 45 as read as read as read as read as read as read 7:00 as read as read as read as read as read as read 7:15 as read as read as read as read as read as read 7:30 as read as reed as read as read as ned as read 7:45 as read as nad as nad as read as read as read 8.00 as ned as read as read as nad as read as read 8:15 as read as read as read as read as read as read 8:30 as read as read as nad as read as read as read 8:45 as read as read as ned as read as read as read 9:00 as read as read as read as read as read as read 9:15 as read as read as read as read as read as read 9 30 as read as read as ned as read as remi as read 9:45 as read as read as read as read as read as read 10:00 as read as read as read as read as read as read 10:15 as read as read as read as read as read as read 10:30 as read as read as read as read as read w read 10.45 as read as read as read as read as read as read 11:00 as ned as read as read as reed as read as ned 11:15

. as read as med as read as read as ned as reed 11:30 as remt as read as read as read as read as read 11:45 es read as read as nad as read as read as read 12:00 na read as read as nad as reed as read as read 12:15 as read as read as read as read as read as read 12:30 as read as read as read as read a read as read 12:45 as read as read as read as read as read as read 13:00 es read as read as remi as ned as read as read 13:15 as read as read as read as ned as read as read 13:30 as read as read as read as read as read as read 13:45 as read as read as read as ned as read as nad 14 00 as read as read as read as read as read as read

-i 1

i EXERCISE \\ONFC4,XLS 5-48 Rev. 6/8/93 1

DOSE ASSESSMENT DATA and PLUME MAPS METEOROLOGICAL DATA

SUMMARY

(Cont)

Wind Direction Wind Speed Delta Temp Ambient Temp.

Pasquill Target Time (From)

(mph)

(*CJ100m)

('C)

Class Sectors 110m 45m 10m 10m 110m 45m 10m 10m 10rn 10m 10m 06.00 082.2 081.8 080.0 080.8 7.1 6.8 6.0 5.8

-1.5

-1.6

-1.5 22.6 22.7 22.5 C

N 06.15 0872 086.8 086.0 085.8 8.1 7.8 6.0 6.8

-1.5 1.6

-1.5 22.8 23.0 22.8 C

N 06:30 085.2 084 8 083.0 083 8 8.6 8.3 6.6 7.3

-1.5 1.6

-1.5 22.8 23.0 22.8 C

N 06:45 086.2 085.8 084.0 084.8 9.1 8.8 7.0 7.8

-1.5

-1.6

-1.5 22.9 23.1 22.9 C

N 07.00 087 2 086.8 086.0 085.8 8.6 8.3 6.6 7.3

-1.5

-1.6

-1.5 23.0 23.2 23.0 C

N 07:15 088 2 087.8 086.0 086.8 9.3 9.0 7.2 8.0 1.5

-1.6

-1.5 23.6 23.7 23.5 C

N 07.30 092 2 091.8 090.0 090 8 86 8.3 6.6 7.3

-1.3

-1.4

-1.3 24.0 24.2 24.0 D

N 07:45 1032 102.8 101.0 1 01.8 8.3 8.0 6.2 7.0

-1.3

-1.4

-1.3 24.1 24.3 24.1 D

N 08:00 1042 103.8 102.0 102.8 7.9 7.6 6.8 6.6

-1.3

-1.4

-1.3 24.0 242 24 0 D

P 08.15 1062 1058 104.0 104 8 7.6 7.3 6.6 6.3

-12

-1.3 1.2 24.2 24 4 242 D

P 08.30 1082 107.8 106.0 106 8 7.2 6.9 6.1 5.9

-08

-0.9

-0.8 24.8 25.0 24.8 D

P 08 45 1112 110 8 109.0 1098 7.1 68 6.0 5.8

-0.7

-0.8

-0.7 26.2 25 4 252 D

P 09 00 112.2 111.8 110.0 110 8 7.3 7.0 6.2 6.0 45

-0.6

-0.5 26.0 252 25.0 D

P 0915 114.2 113.8 112.0 112.8 7.1 68 6.0 58

-04 4.5

-0.4 26.3 25.5 25.3 D

P 09 30 113.2 112.8 111.0 111.8 7.2 6.9 6.1 5.9

-0.2 4.3 -02 26.6 26.7 25.5 E

P i

09.45 1142 113.8 112.0 112.8 7.1 6.8 6.0 58 0.0 4.1 0.0 27.3 27.5 27.3 E

P 10:00 1131 112.8 111.0 111.8 7.3 7.0 6.2 60 0.0 4.1 0.0 28.0 28.2 28.0 E

P 10:15 1192 178.8 117.0 117.8 6.9 6.6 4.8 56 2.1 2.0 2.1 28.1 28.3 28.1 F

P-10 30 1182 117.8

'16.0 116.8 6.8 6.5 4.7 5.5 2.0 1.9 2.0 28.2 28.4 28 2 F

P 10.45 120.2 119 8 118.0 118 8 6.5 6.2 4.4 5.2 2.2 2.1 22 28.0 28 2 28.0 F

P 11:00 118 2 117.8 116.0 116.8 6.4 6.1 4.3 51 2.1 2.0 2.1 28.1 28.3 28.1 F

P 11:15 1212 120 8 118.0 119 8 6.8 6.5 4.7 5.5 22 2.1 2.2 28.0 28 2 28.0 F

P 11:30 121.2 120.8 119.0 119 8 7.1 6.8 6.0 5.8 2.3 2.2 2.3 28.2 28.4 28.2 F

P 11:45 195.2 195.8 194.0 1948 6.6 6.3 4.6 5.3 2.1 2.0 2.1 28.0 282 28.0 F

B 12 00 2102 209.8 208.0 208.8 6.5 6.2 4.4 52 2.1 2.0 2.1 28.1 28.3 28.1 F

B 12.15 2122 211.8 210.0 210.8 6.7 64 4.6 5.4 2.0 1.9 20 28.0 28.2 28.0 F

B 12.30 214.2 213.8 212.0 212.8 6.9 66 4.8 56 2.1 2.0 2.1 28.2 28.4 282 F

B 12 45 213 2 212.8 211.0 211.8 6.9 66 4.8 56 2.0 1.9 2.0 28.0 282 28.0 F

B 13 00 212.2 211.8 210.0 210.8 7.0 6.7 4.9 57 2.2 2.1 2.2 28.1 28 3 28.1 F

B 13 15 210.2 209 8 208.0 208 8 72 69 6.1 5.9 2.1 2.0 2.1 28.0 282 28 0 F

B 13.30 2102 209 8 208.0 208.8 7.2 69 6.1 5.9 2.1 2.0 2.1 28.2 28 4 28.2 F

B Pasouill Class Definitiom gog Bold faced data (first set of daza for 10m elevation) is data used to calculate offsite x <= 1.9 very unstable A

radiological eleases.

1.9 < x <= -1.7 unstable B

-1.7 < x <= -1.5 slightly unstable C

1.5 e x <= -0.5 moderate D

0.5 < x== +1.5 slightly stable E

+ 1.5 e x <= +4.0 stable F

x > +4.0 very stable G

hieteorolonical Forecast 06/29'93: Clear start to the day with possible late morning clouds. Tempera:ures expected from a low of 65'F to a high of 85'F.

Mild breezes from the cast are expected of about 5 mph during most of the day and are expec'.ed to shift from the south. A 309E chance for precipita: ion is forecast for the late morning. Skies should clear again in the afternoon, oxaciscutTsuu.xts 7-3 Rev. 6/2/93

FORT CALHOUN 1 OF 14 FIELD TEAM EOUIPMENT TIME:

0630 - 10:15 ESP 2 RSO5 FrinLer/ IIP-260 har instrument Readings Instrument Readings Activity smear particulate iodine Does Rate smear particulate dpm/100cm2 Centerline Maximums net even mes cpm (dpm)

(mR/hr) net epm set epm 2.00 mi as read as read as read as re.ed u read as read as read 5.00 mi e

10 00 mi i

t t

hie Houndary Distana none i

Special Receptor:

none Emergency Monitorint Poirits none t

t t

P h

I e

  • Controller /evatwdor reference data only.

EXERCISE \\EQUIPFC.XLS 7-25 Rev. 6/8/93 e

FORT CALHOUN N"

FIELD TEAM EOUIPMENT 71ME:

1015 - 10:33 ESP-2 RSO5 -

Frisker/ HP.260 3mear Instrument Readings Instrument Readings Activity smear particulate iodine Dome Rate -

amear particulate dpm/100cm2 Centerline Maximums net cpm met epm (dem)

(mR/hr) net cpm act epm 2.00 mi as read as read as read as read as read as read as read 5.00 erd as read as read as read as read as read as read as nad 10.00 mi as read as read as read as read as read as read as read Site Boundarv Detance sector P D.7 mi 2.0E + 01 5.3E+04 3.0E + 04 4.8E + 00 2.0E + 0!

5.3E+04 2.0E + 02 Special Receptors none Emergency Monitoring Points P1 0.5 mi 1.4 E+ 02 3.7E+05 2.5E+ 05 4.4E + 01 1.4E +02 3.7E + 05 1.4E+03 P2 0.6 mi 7.6E-01 2.2E+03 as read 2.2E-01 7.6E-01 2.2E+03 7.6E+00 t

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-26 Rev. 6/8/93

N FORT CALHOUN 3 0F 14 FIELD TEAM EOUIPMENT 71ME:

1030 - 10:45 ESP.2 R505 Frinker/ IIP-260 Smear Instrument Readings Instnmwn Re=Img.

Activity emear particulate kdme Dome Rate amear pasticulate.

dprn/100cm2 Centerline Maximuma net cpm net epm (dpm)

(mR/hr) net epm net epm 2.00 mi 3.6E+ 01 9.6E + 04 4.2E + M 5.7E + 00 3.6E+ 01 9.6E+04 3.68 +02 5 00 ml as read as read as read as read as read as read as read -

10.00 mi as read as read as read as read as read as read as read Site !!oundary Distance sector P 0.7 mi

8. l E + 01 2.1E+ 05 1.2E+ 05 1.9E+ 01 es read 4.6E+02 8.1E + 02 Special Receptors none 0.0 mi es read as read as read as read as read as read as seed Emergency Monitoring Points P1 0.5 mi 9.4E+ 01 2.5E+ 05 1,7E + 05 2.9E + 01 as read 6.4 E+ 02 9.4E+ 02 P2 0.6 mi 6.3 E + 00 1.6E+ 04 1.0E+ 04 1.7E +00 as read 3.9E+ 01 6.3E+0!
  • Controllerlevaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-27 Rev. 6/8/93 t

FORT CALHOUN N"

l FIELD TEAM EOUTPMENT TIME:

1045 11:00 ESP 2 R505 Frisker/ HP-260 5mear Insuunmit R adinas Instrument Readinas Activity smear

%ete '

iodine Dase Rate amcar particulata dpm/100cm2 Centerline Maximums net epm met epm (dpm)

(mR/hr) net epm net epm 2.00 mi 7.3E+01 2.0E+ 05 8.6E + 04 1.2E + 01 7.3 E+ 01 2.0E+05 7.3 E+ 02 3.00 mi 2.4E+01 6.4E+04 3.1E + 04 3.7E+ 00 2.4E+ 01 6.4E+04 2.4 E+ 02 5.00 mi as read as read as read assend as read as read as read 10.00 mi as read -

as read as read as read as read as read as read Site Boundary Distance sector P 0.7 mi 1.4E+ 01 3.7E + 04 2.0E + Gt 3.4E+00 1.4E + 01 3.7E + 04 1.4E + 02 Special Receptors Blaar 3.2 mi 1.2 E + 01 3.2E+ 04 1.6E + 04 1.8E+ 00 1.2E + 01 3.2E+04 1.2E+02 Emergency Monitoring Points P1 0.3 mi 5.7E+ 02 1.5E+06 9.7E + 05 1.6E+ 02 5.7E + 02 1.5E+06 5.7E+03 P2 1.2 mi 3.1E-01 8.7E+02 as read as read 3.1P 01 8.7E+02 3.8 B+00 P4 1.8 ml 6.6E + 00 1.8E + 04 8.7E + 03 1.0E+00 6.6E+00 1.8E+ 04 6.6E+0!

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-28 Rev. 6/8/93 y

n

FORT CALHOUN O OF 14 FIELD TEAM EOUIPMENT TIME:

1100 - 11:15 ESP 2 RSOS Fraker/ HP.260 Smear instnanent Readings Instrument Readings Activity emeer partrulais iudme Dome Rate amear particulate dpm/100cm2 Centerline Maximums mes epm act epm (dem)

(mR/hr) net cym met epm 2.00 mi 9.4 E + 01 2.5E+05 1.1 E + 05 1.5E+01 9.4E+01 2.5E + 05 9.4 E + 02 3.00 mi 3.3E + 01 8.8E + M 4.3E+ M 5.lE+ 00 3.3 E+ 01 8.8E +04 3.3E+02 l

4.00 mi 1.2E+ 01 3.3 E + 04 1.9E+ 04 2.0E+00 1.2E+01 3.3E+ 04 1.2E+02 10.00 mi as read as read as read as read as read as read as read Site Boundary Distance sector P 0.7 mi 1.1E+ 02 3.0E + 05 1.6E+ 05 2.6E+ 01 1.1E+ 02 3.0E+05 1.1E+03 Special Receptors Blair 3.2 mi 1.5E + 01 3.9E+ 04 2.0E+ 04 2.2 E + 00 1.5E + 01 3.9E + 04 1.5E+02 Emergency Monitonnt Points P1 0.5 mi 1.3 E +02 3.5E+ 05 2.3E+ 05 4.0E + 01 1.3 E + 02 3.5E+05 1.3E+03 P2 0.6 mi 9.4E+00 2.5E + 04 1.5E + 04 2.4E+ 00 9.4E+00 2.5E + N 9.4E+01 -

P4 3.2 mi 7.5E+ 00 2.0E + 04 1.0E + 04 1.1E+00 7.5E+ 00 2.0E4 04 7.5E+01 P5 3.7 mi 1.8E+01 4.9E + 04 2.7E+ 04 2.9E+ 00 1.8E+ 01 4.9E+04 1.8E+ 02 P6 4.3 mi as reed as read as read as read as read as read as read i

I s

}

1

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-29 Rev. 6/8/93

FORT CALHOUN 6 OF 14 FIELD TEAM EOUIPMENT nun lits. 21:30 E5P-2 RSO5 Frisked itP-260 Smear Instrument Readings Instrument Readings Acuvity smear paruculate imimo Dose Rate -

ament partaculais dpm/200cm2 Centerline Maximums act epm na epm (dem)

(mR/hr) nei cpm met epm 2.00 mi 9.6E + 01 2.6E + 05 1.1 E + 05 1.6E + 0!

9.6E+ 01 2.6E+ 05 9.6E + 02 3 00 mi 5.2 E + 01 1,4 E + 05 6 RE+04

8. l E + 00 5.2E + 01 1.4 E + 05 5.2E+ 02 4.00 ml
2. l E + 0!

5.6E + 04 3.2E+ 04 3.4 E + 00 2.1E+ 01 5.6 E+ M 2.1E+02 5.00 mi 8.3 E + 00 2.1E+ 04 1.5E+04 1.4E + 00 8.3 E+00 2.1E+ 04 8.3E+0!

10.00 mi es read as read as read as reed as read es read as read Site Boundary Dwtance sector P 0.731 2.2E + 00 6.2E + 03 as read 9.BE-01 2.2E+ 00 6.2E + 03 2.2E+ 01 Sperial iteceptors Blair 3.22 3.3 E+ 0!

8.8E+ 04 4.5 E + 04 5.2E+ 00 3.3E+01 8.8 E + 04 3.3E+ 02 Emergency Monitoring Points P1 0.5 6.3E +02 1.6E+ 06 1.1 E + 06 1.9E + 02 6.3 E+ 02 1.6E + 06 6.3 E+ 03 P2 0.6 as reed as read as read as read as read as read as read P4 3.2 2.IE + 01 5.7E+ 04 2.9E + M 3.3E+ 00 2.1E+ 0!

5.7E+04

2. l E+ 02 P5 3.7 1.9E+ 01 4.9E + 04 2.7E+ 04 2.9E + 00 1.9E + 01 4.9E + 04 1.9E+02 P6 4.3 as read as read as read as read as read as read as read j

i

)

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-30 Rev, 6/8/93 l

FORT CALHOUN 7 OF 14 FIELD TEAM EOUIPMENT

'IST:

1130 - 11:45 4

ESP 2 R505 Frisker/ HP.260 Smear Instrument Readinre

- Instnanent Readinge Activity smear particulate iodme Dame Rate smear particulate dpm/100cm2 Centerline Maximums net epm met epm (dpm)

(mRh) net epm met epm 2.00 mi 7.4E+ 01 2.0E+ 05 8.7E+04 5.9501 7.4E+ 01 2.0E+ 05 7.4E+ 02 3.00 mi 4.8E + 01 1.3 E+ 05

6. t E + 04 7.6E + 00 4.8E+ 01 1.3E+ 05 4.8E+ 02 4.00 ml 3.0E + 01 7.BE+04 4.4 E+ N 4.8E+ 00 3.0E+01 7.8 E+ 04 3.0E+ 02 5.00 nd 1.3E+0!

3.4 E+ 04 2.4 E+ 04 2.3 E+ 00 1.3 E+ 0!

3.4E+ 04 1.3E+02 6,00 ad 5.4E+00 1.4E+04 1.2E + 04 1.1E+ 00 5.4E+00 1.4E + 04 5.4E+01 10.00 mi as read as remi as read as read as read as read as med Site Boundary Distance sector P 0.7 mi 1.6E+ 00 4.65 + 03 as rend 8.2 & 01 1.6E + 00 4.6E + 03 1.6E+01 Special Receptors Blair 3.2 mi 3.7E + 01 9.9E + M 4.9E + 04 5.8E+ 00 3.7E+ 01 9.9E+ M 3.7E+02 Emerrency Monitoring Points P1 0.5 mi

5. l E + 02 1.3 E + 06 9.3 E + 05 1.6E+ 02
5. ! E+ 02 1.3E+06 5.! E+ 03 P2 0.6 mi as ned as read as read as read as read as ned as ned P4 3.2 mi 2.8E+0!

7.4E + 04 3.6E + N 4.3E+ 00 2.8E+ 01 7.4E + 04 2.8E+02 P5 3.7 ed 1.7E+02 4.7E +05 2.5E +04 2.8E+ 00 1.7E+02 4.7E + 05 1.7E +03 F7 6.8 mi 2.8E+ 00 7.0E+ 03 7.4 E+ 03 6.0E.01 2.8E+ 00 7.0E+(0 2.8E+ 01 Q1 2.5 ud as read as md as read as read as read as read as remi i

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-31 Rev. 6/8/93

FORT CALHOUN e or 14 FIELD TEAM EOUIPMENT 11ME:

1145 - 12:00 ESP-2 RSOS Frinker/ }{P 260 Smear intrunent Readings instrument Readings Activity smear paniculats iodins Dose Rata smear particulats dpm/100cm2 Centerline Maximums met epm nei cprn (dpm)

(mR/hr) net epm nat open 2.00 mi 6,3 E + 01 1.7E + 05 7.7E+ 04 9.8 E + 00 6.3E+01 1.7E+05 6.3 E + 02 3.00 mi 3.7E+01 9.9E + 04 5.2E + N 3.4 E + 00 3.7E+ 01 9.9E + M 3.7E + 02 4.00 mi 2.0E+ 0!

5.3E+ 04 3.5E+ 04 1.6E+00 2.0E+ 01 5.3 E + M 2.0E+ 02 5.00 mi 8.4E+00 2.2E+ 04 1.8E+N 3.2E+00 8.4E+00 2.2E+04 8.4E+ 01 6.00 mi 4.4E.01 1.2E+ 03 as send as read 4.4E-01 1.2E+ 03 4.4E+00 10.00 ml as ned as read as read as read as read as road as read Site Boundary Distance sector P 0.7 ini es read as read as read 3.4L01 as read as read as med sector B 0.7 mi 2.7E-01 7.6E+ 02 as read as read 2.7L01 7.6E+02 2.7E+00 special Receptors Blair 3.2 mi as read as read as read 1.5E.01 as read as read as read Flynn 3.4 mi as read as read as read as reed as read as read as read Emergency Monitoring Points B1 0.1 mi 1.1E+04 2.3E+07 7.6E+ 07 1.5E + N 1.lE+04 2.3E+ 07 1.1E+ 05 P1 0.5 mi as read as read as read 4.3E+M as read as road as read R3 2.3 ml 4.9E+ 01 1.3 E + 05 6.2E + 04 7.5E+ 00 4.9E + 0!

1.3 E + 05 4.9E+02 Q6 5.7 mi 7.6E+00 1.9E+M 1.9E+N 1.6E+ 00 7.6E+ 00 1.9E+04 7.6E+ 01 i

I

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-32 Rev. 6/8/93 i

a FORT CALHOUN e or 14 FIELD TEAM EOUIPMENT TIME:

1200 12.15 ESP-2 R305 Frisker/ HP.260 Smear lutrument Readmas Instrument Readmgo Activiw amear partaculate iodme Does Rate smear particulate dpm/100cm2 Centerline Maximums net epm net epm (dem)

(mR!hr) net com net epm 2.00 ad 6.0E+01 1.6E+05 7.2E+ 04 9.5E+ 00 6.0E + 01 1.6E+0S 6.0E+02 3.00 mi 2.1 E+ 01 5 4E+04 3.0E + 04

- 3.1E+00 2.1 E+ 01

$.4E+04 2.1E+02 4.00 mi 1.7E + 01 4.3 E + M 3.2E+04 1.5E+ 00 1.7E+01 4.3 E+ 04

-1.7E+02 5 00 ml 7.2E + 00 1.8E+04 1.lE+04 9.9E.01 7.2E + 00 1.8E+04 7.2E+01 6.00 mi 4.2E + 00 1.0E + 04 1.3 E + 04 2.1Fe01 4.2E+ 00 1.0E+04 4.2E+0! '

10A0 mi as read as read as read as read as read as need as semi 1

Site Boundary Distance sector B 0.7 mi 6.9E + 00 1.8E+04 9.8E + 03 3.1 E+ 00 6.9E + 00 1.8E+04 6.9E+01 sector P 0.7 mi es reed as read as read 1.6E + 00 es read as read as read Special Receptors Blair 3.2 mi as read as read as read 1.3E.01 as read as read as read Emetrenev Monitoring Points A2 2.1 mi e read as read as read as read as read as read as read B1 0.1 nu u read as read as seed 1.0E+02 as read as read

. as read B3 2.0 mi as read as read as read as read as read as read as read P1 0.5 mi as read as read as read 3.9E + 00 na read as read as read Q7 6.7 mi 1.8E+00 4.2E + 03 6.6E+ 03 4.8E41 1.8E+ 00 4.2E + 03 1.8E+01 r

i l

l l

1 1

  • Contro!!er/ evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-33 Rev 6/8/93

\\

FORT CALHOUN 10 OF 14

)

FIELD TEAh! EOUIPhiENT TIME:

1215 - 12:30 i

ESP-2 RSOS Frisker/ MP.260 Smear fastrument Readinre Instrument Reedinge Activiry ameer particulate iodme Does Rats ameer pasticulats dpm/100cm2 Centerline Maximums net epm net epm -

6 tem)

(mIUhr) net cpm net epm 2.00 ad 4.7E + 0!

1.3 E + 05 5.1 E + 04 7AE+00 4.7E+ 01 1.3 E+ 05 4.7E+02 3.00 ml 1.2E+ 01 3.1E+04 I.5E4 04 1.8E+ 00 1.2E+ 01

3. l E + 04 1.2E+ 02 4.00 mi 1.3E+ 01 3.4E+04 2.5 E+ 04 1.6E+ 00 1.3E+ 01 3.4E+04 1.3E+02 5.00 mi 5.7E+00 14E+04 1.6E+ 04 1.3E+ 00 5.7E+ 00 1.4E + 04 5.7E+ 01 6.00 mi 3.8E+00 8.9E+ 03 1.3 E + 04 9.7501 3.8 E + 00 8.9E + 03 3.8E+ 01 8.00 mi as read as read as read as read as read as read as read 10 00 mi as read as read as read as read as read as read as read i

Site Boundarv Distance occtor B 0.7 mi as reed as read as read as reed as read as read as read sector P 0.7 mi as reed as read as read Special Recepton Blair 3.2 mi as reed as real as read 1.2E-01 as read as read as read timergency Monitoring Points B1 0.1 mi as read as reed as read 9.1 E + 01 asreed as read as read B2 1.9 mi 2.1E+ 01 5.5E+04 2.4E+04 3.3 E + 00

2. l E+ 01 5.5E + 04 2.1E + 02 B4 3.2 mi 3.2E+01 8.4 E + 04 4.3 E + 04 4.8E+00 3.2 E + 01 8.4E+04 3.2E+ 02 P1 0.5 mi as read as read as reed 3.5E+00 as read as read as read R5 4.5 mi 1.lE+ 01 2.7E + 04 2.4E+04 2.1E+ 00 1.1E + 01 2.7E+04 1.1E+02 R6 5.2 mi 7.5LOI 2.1 E + 03 as read 2.0E-01 7.5E-01
2. ! E+ 03 7.5E+ 00 R7 6.2 mi 1.1 E + 00 3.2E + 03 es read 3.8E-01 1.1 E + 00 3.2E + 03 1.1E +01 l

l 1

1 I

l I

  • Controller / evaluator reference data only.

l EXERCISE \\EQUIPFC.XLS 7 34 Rev,6/8/93 i

FORT CALHOUN

" F 54 FIELD TEAM EOUIPMENT 11ME:

1230 - 12:45 E5P.2 R505 Fruker/ HP.260 Sacar Instnanent Readings instnanent Pendine Activief amear particulate iodine Does Rate amear particulate dpm/100cm2 Centerline Maximums met com met epm (dpm)

(mR/hr) nea erm act epm 2.00 mi 1.8E+01 4.9E + 04 2.2E+ 04 2.9E+00 1.8E+01 4.9E + 04 1.8L+ 02 3.00 mi 1.3 E + 01 3.4 E + 04 1.7E +04 2 0E+00 1.3 E + 01 3.4 E + M 1.f E+02 4.00 ml

1. 8E + 01 4.7E + 04 2.7E+04 2.8E+00 1.8E+01 4.7E+ 04 18E+ 02 5.00 mi 5.3E + 00 1.3E+ 04 1.9E+ 04 1.7E+ 00 3.3E+ 00 1.3E+04 5.3E+01 6.00 mi 2.4E+00 4.7E+ 03 1.5E+ 04 1.1E+ 00 2.4E+ 00 4.7E+ 03 2.4E+01 8.00 mi 64401 1.8E+ 03 as read 3.4 & 01 6.4501 1.8E+03 6.4E+ 00 10 00 mi es read as reec' as read as read as read as read as read Site Boundary Dstence sector B 0.7 mi as read as read as read as read as read as read as read sector P 0.7 mi as read as read as read 2.7&O1 as read as read as read Srecial Receptors Blair 3.2 mi as read as read as res.1 1.1501 as read as read es read Emerrency Monitoring Points A3 5.9 mi as read as md as read as real as read l

as read as read A5 6.3 mi as read as reef as read a read as read as read as read DI 0.1 mi as reed as read as read 8.3 E + 01 as read as read as read B2 1.9 mi 4.5E + 01 1.2E+ 05 5.3 E + 04 7.3 E + 00 4.5E + 0E 1.2E + 05 4.5E+02 B5 3.9 mi 1.2E+01 3.1E + 04 1.7E+ 04 1.8E +00 1.2E+01 3.!E+04 1.2E+02 C1 0.1 mi as read as read as read as read as read as read as read P1 0.5 mi as read as read as read 3.2E+ 00 as read as reed as read R8 7.7 mi 3.9&O1 1.1E+ 03 as read 1.8 & 01 3.9501 1.1E+ 03 3.9E+00 R9 8I mi 6.2501 1.8E+03 as read 3.3E 01 6.2E.01 1.8E+ 03 6.2E+ 00 t

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-35 Rev. 6/8/93

FORT CALHOUN 13 0F 14 HELD TEAM EOUIPMENT 11ME:

1245 - 13:00 ESP.2 R505 Frisker/ HP.260 Smear -

Instrument Readings Instrument Readings Acuvity smear particulate todme Dose Rate smear parbculate dpm/100cm2 Centerline Maximums net epm net cpen (dpm)

(mR/hr) net cpm net crm -

2.00 m 1.8E + 01 4.8E+N

2. l E + N 2.9E+00 1.8E+01 4.8E+M 1.8E+02 3.00 mi 8.9E+00 2.4 E+ 04 1.1 E + 04 1.4 E + 00 8.9E + 00 2.4E + N 8.9E+ 01 4.00 mi 5.7E+00 1.5E+ 04 8.4E +03 9.0501 5.7E + 00 1.5E+N 5.7E + 01 5 00 mi 9.4E+ 00 2.4E+ 04 1.7E+04 1.6E+ 00 9.4E+00 2.4E+ 04 9.4E+0!

6.00 mi 5.4E+ 00 1.3 E+ 04 1.6E+04 1.2E+00 5.4E+00 1.3E+N 5.4E+01 8.00 mi 1.2E+ 00 2.5E +03 8.0E+ 03 4.8501 1.2E+ 00 2.5E+ 03 1.2E+01 10.00 mi as read as real as reed as rest as read as read as read Site Boundarv Datance sector B 0.7 mi as ned as read as read as read as reed as read as read sector P 0.7 mi u read as read as ned 2.5LO1 as read as read as read Special Receptors Blair 3.2 mi as read as read u read as read as read as read as read Emergency Monitoring Points A3 5.9 mi as read as read as read as read as read as read as read A4 6.0 mi 5 OE+00 1.2E+04 1.5E+04 1.2E+ 00 5.0E+ 00 1.2E+ 04 5.0E+01 A5 6.3 mi 3.6501 1.0E+ 03 na read 1.3E-01 3.6E-01 1.0E+03 3.6E+ 00 A6 1.1 mi 9.1E.01 2.6E + 03 as ned 2.9501 9.1501 2.6E+ 03

- 9.1B+00 B1 0.1 mi es read as read as read 7.6E + 01 e read a read as read B2 1.9 mi 3.9E + 01 1.0E+05 4.6E+04 6.4 E+ 00 3.9E+01 1.0E+05 3.9E+ 02 B4 3.2 mi as read a read as read as need as read as reaJ es read B5 3.9 mi 1.5E+01 4.0E+ 04 2.2E+04 2.4E+00 1.5E+ 01 4.0E+04 1.5E+ 02 B6 5.3 mi 8.8E+00 2.3E+ N 1.7E+ 04 as ned 8.8E+00 2.3 E+04 8.8E + 01 B7 6.5 mi as read as read u reed as read as read as read as read P1 0.5 mi as read as read as read 3.0E + 00 as read as read as read RS 7.7 mi as reed as read as read as remi as read as read as read t

i I

  • Controller! evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-36 Rev. 6/8/93

FORT CALHOUN 13 0F 14 F1 ELD TEAM EOUIPMENT 11ME:

1300 - 13:15 I

ESP-2 RSOS firisker/ HP-260 Smear I

Instrument Readinge instnanent Readinas Activiry smear partaculate iodme Dose Rats emear particulata dpm/100cm2 centerbne Maximums net cpra net cpm (dem)

(mR/hr) vet epm net epm 2.00 mi 1.3 E + 01 3.5 E + 04 1.5E +04 2.2E + 00

f. 3E+01 3.SE + 04 1.3 E+02 3.00 mi 6 8E+00 1.8 E + 04 8.7E + 03 1.0E+00 6 SE+00 1.8E+ 0s 6.8 E + 01 4.00 mi 3.7E+ 00 1.0E + 04 as read 6.2 & 01 3.7E+00 1.0E + 04 3.7E+01 5.00 mi 1.8 E + 00 5.0E+ 03 as read 5.8B.01 1.8 E+00 5.0E+ 03 1.8E+01 6.00 mi 3.5E + 00 8.9E+ 03 9.2E + 03 8.1501 3.3E+00
8. 9E+ 03 3.5E+ 01 8.00 mi 1.9 E + 00 4.0E + 03 1.1E+ 04 6.8 & 01 1.9 E+ 00 4.0E + 03 1.9E+ 01 10.00 nu as read as read u read as read as read as read as read Site Boundary Distance I

sector B 0.7 mi as read as read as read as.ead as read as read as read sector P 0.7 mi as read as read as read 2/JE01 as read as read as read Special Heceptore Blair 3.2 mi as read as read as read as read as read as read as read Modale 7.7 mi as read as read as read as read as read as rent as read Emergency Monitoring Points A6 1.1 mi as read as read as read as read as read as read as read A7 7.8 mi 2.1 E + 00 4.5E+03 1.1 E + 04 7.0 & 01 2.1 E + 00 4.5 E + 03 2.1E+ 01 A9 8.8 mi 2.4 & 01 6.9E + 02 as read 1.4 & 01 2.4&O1 6.9E + 02 2.4E+00 B1 0.1 mi as read as read as read 7.0E+01 as read as read am read B2 1.9 mi 1.9E+ 01

$.2E+ 04 2.3E+ 04 3.3E+ 00 1.9E +01 5.2E + 04 1.9E+02 j

B4 3.2 mi as read as read as need as read as read as read as read

{

B5 3.9 mi 1.2E+ 01 3.2E+04 1.7T.+ 04 1.9E+ 00 1.2E+01 3.2E+ 04 1.2E+02 D6 5.3 mi 5.7E+ 00 1.5E + 04 1.! E + 04 1.0E + 00 5.7E+ 00 1.5E+ 04 5.7E+ 01 B7 6.5 mi 9.3 &O1 2.6E + 03 es read 2.2 & 01 9.3 & 01 2.6E+ 03 9.3E+ 00 B8 7.8 mi as read as read se read as read as read as read as read P1 0.5 mi as read as read as read 2.8E+ 00 as vend as read as read l

l i

4

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-37 Rev. 6/8/93 i

I FORT CALHOUN F 14 -

DELD TEAM EOUIPMENT I

TIME:

1315 - 13:30 I

ESP.2 R305 Irisker/ HP 260 smear Instnewnt Reedmes Instnunent Reedmas Activity smear particulate iodine Dose Rate smeer paruculate dpm/100 era 2 centerline Maximums nee epm act epm (dpm)

(mR/hr) net epm net cinn 2.00 ml 9.0E+00 2.4E4 04 1.1 E+ 04 1.6E+ 00 9.0E+ 00 2.4 E + 04 9.0E+01 3.00 mi 1 lE+01 2.8 E + 04 1.3 E + 04 1.6E + 00

1. l E + 01 2.8E + 04 1.lB+02 '

4.00 mi 7.0E+ 00 1.9E+ 04 1.0E + 04 1.5&O1 7.0E + 00 1.9E+04 7.0E+01 5,00 ml 3.9E + 00 1.0E +04 6.7E+03 6.6E01 3.9E+00 1.0E + 04 3.9E+01 6.00 mi 2.2E +00 6.3E+ 03 se read -

4.6 & 01 2.2E+ 00 6.3E+03 2.2E+ 01 8 00 mi 3.0E+ 00 7.2E+ 03 9.8E + 03 7.4&ol 3.0E+ 00 7.2E+03 3.0E+ 01 10.00 mi 3.5 & 01 9.9E + 02 as read 3.0E01 3.5501 9.9E + 02 3.5E+00 Lte Boundary Distance sector B 0.74 mi 1.l E + 00 3.2E + 03 as ned 3.0&O1 1 lE+00 3.2E+03 1.1 E + 01 sector P 0.73 mi as read as ned as ned 2.2501 m read as read as read Special Receptors Blair 3.2 mi as reed as read as read na read asremi as ned as read Modale 7.7 mi 2.2E+00 6.3E + 03 8.2E+ 03 6.2501 2.2E+ 00 6.3E+ 03 2.2E+ 01 Emergency Monitoring Pointa A8 8.0 mi 2.2 & 01 6.4E+ 02 as read as read 2.2 & 01 6.4 E + 02 2.2E+ 00 A9 8.8 mi as read as read as read as rea:l es road as read as read A10 9.2 mi 5.6 & 01 6.4E+ 02 7.5 E+ 03 4.5E01 5.6E 01 6.4E+ 02 5.65 +00 B1 0.1 mi as read as read as read 6.5E+ 01 as read as read esved B2 1.9 mi 2.lE+ 00 6.0E + 03 as read 5.4 & 01 2.1E+ 00 6.0E+03 2.1E+01 B4 3.2 mi as read as reed as read as read as read as read as read B5 3.9 mi 1.1E+ 01 3.0E+ 04 1.6E + 04 1.8E+ 00 1.1E+01 3.0E+ 04 1.1E+ 02 B6

$.3 mi 5.4 E + 00 1.4 E + 04 9.9E+ 03 9.5LO1 5.4E+00 1.4E + 04 5.4E+ 01 B7 6.5 mi es reed as reed as read as ned as read as read as read B8 7.8 mi 8.0 & 01 2.3 E+ 03 as read 2.4501 8.0 S 01 2.3 E+ 03 8.0E+00' i

11 9 8.4 nd

2. l E + 00
4. 8 E+ 03 9.1E+ 03 6.2601 2.1E+ 00 4.8E+03 2.1E + 0!

P1 0.5 mi as read as read as read 2.6E+ 00 as read as read as read

  • Controller /cvaluator reference data only.

EXERCISE \\EQUIPFC.XLS 7-38 Rev. 6/8/93

STATE OF NEBRASKA 1 *' "

FIELD TEAM EQUIPMENT 11ME:

0630 - 101$

E520 / (HP-260 or HP-21OT)

RO-2 Done Rates E 520 / (HP.260 or HP-210T) fiets f%rticulate (fiher)

(mR/hr) lodme (cartrktge)

Cont.

SH4 1.5 inch 3 inch 3 inch 3 & 5 ft.

3&5fL

. Cont.

5H4

.1.5 axh Centerbne Maximums net epm net epm net epm open chmed open chmed net cTwn net epm nee epm all as read as read as read na read as read as read as read as read as read as read Site Iloundary Datarre Special Receptors none Emergency Monitoring Points none I

i l

9 I

I Note:The volume of air used in these calculations is 10 ft3-l 1

  • Controller / valuator reference data only.

t EXERCISE \\EQUIPNE.XLS 7-40 Rev. 6/9/93

STATE OF NEBRASKA 2 of 14

)

FIELD TEAM EQUIPMENT I

TIME.

1015 1030 L520 / (HP 260 or HP-210T)

RO.2 the Reies L520 / (HP-260 or HP-2107)

Hets Particulate (fiher)

(mR/hr) lixime (cartridge)

Cont.

5H4 1,5 inch 3 mch 3 inch 3 & 5ft 3 & 5 ft.

Cont.

SH4 1.5 inch

)

Centerline Macimums net epm net epm net epm open closed open chwed net epm met epm net epm 2.00 mi as remi as read as read as read an real as rest as remi as read as real as read 1

5 00 mi as remi as read as read as read as rmi as read as read as read es read as read 10.00 mi as read as read as read as read me read as read as read as read as read as read I

J Ltc Boundary Distance sector P 0.7 mi

1. l E + 05 8.0E + 04 1,6E + 04 5.3 E+ 00 5.3 E+ 00 4.8 E+ 00 4.8 E + 00 7.8 E + 01 3.9E + 01 1.2E + 01 Special Receptors none Emcerency Monitoring Points P1 0.5 mi 7.5E + 05 5.6E+ 05 1.lE+ 05 4.8E + 01 4.BE+ 01 4.4 E + 01 4.4 E + 01 6,6E + 02 3.3 E+ 02 9.9E+ 01 P2 0.6 mi 4.3 E + 03 3.2 E + 03 6.5E+ 02 2.4E 01 2.4 E-01 2.2501 2.2501 as read as read as read Note: The volume of air used in these calculations is 10 ft3.
  • Controller / evaluator refersnes tata only.

EXERCISE \\EQUIPNE.XLS 7-41 Rev. 6/9/93

STATE OF NEBRASKA

- 3 0' 14 FIELD TEAM EQUIPMENT 11ME:

1030 1485 F 520 / OlP-260 of HP-210T)

RO-2 Done Rates E-520 / (HP-260 or HP.210T)

Reta Particulate (fiher)

(mR/hr) lodine (cartridrel Cont SH-4 1.5 inch 3 sh 3 meh 3 A 5 ft.

3 & 5 ft Cent 5H-4 1.5 inch CenterUne Maximuma net epm net epm net epm cren closed open closed act epm net cpm net epm 2.00 mi 1.9E+ 05 1.4 E + 05 2.9E + 04 6.2E + 00 6.2 E+ 00 5.7E + 00 5.7E+ 00 1.lE+ 02 5.5E + 01 1.7E + 01 5 00 mi as read as read as read as read as read as read as read as read as read as read 10.00 mi asrad as read as read as reati as read as read as read as read as read as read Site flounderv Detmace sector P 0.7 mi 4.3 E + 05 3.2E + 05 6.4E+ 04 2.l E + 01 2.1 E + 01 1.9E + 01 l.9 E + 01

3. l E+ 02 1.6E + 02 4.7E + 0E Special Receptors none Emergency Monitoring Points P1 0.5 mi 4 SE+05 3.7E + 05 7.4 E + 04 3.2E+ 01
3. l E+ 01 2.9E + 01 2.8 E + 01 4.3E+02 2.2E+02 6.5E+01 P2 0.6 mi 3.3 E+ 04 2.5E+ M 4.9E + 03 1.8 E + 00 1.8E+00 1.7E+ 00 1.7E+ 00 2.6E + 01 1.3E + 01 4.0E+00

?

Note: The volume of air used in these cakulations is 10 ft).

  • Controllerlevaluator reference data only.

EXERCISE \\EQUIPNE.XLS 7-42 Rev. 6/9/93

A STATE OF NEBRASKA 4 "

FIELD TEAM EQUIPMENT TU 1.

1045 1100 E.520 / (HP-260 or HP-210T)

RO 2 Done Rates E.520 / (HP.260 or HP 2101)

Beta PerQulate (fiher)

(mR/hr) ladine (cartridre)

Coat 5H.4 1.5 inch 3 mch 3 inch 3 & 5ft 3 & 5 ft.

Cont, SH4 1.5 inch Centerline Maxin ams nei cpm met epm net com open ckmed open closed net com net epm net epm 2.00 mi 3.9E + 05 2.9E+05
5. 9E + 04 1.3E+ 0!

1.3 E + 0!

1.2E+ 0!

1.2E+ 0!

2.2E+ 02

1. l E + 02 3.4E+ 0!

3.00 mi 1.3 E + 05 9 6E+04 1.9E + 04 4.0E4 00 4 0E+00 3.7E + 00 3.7E + 00

8. l E + 01 4.0E+ 0!

1.2E+ 01 5.00 mi u read as read as read as read as read as read as read as read as real as read 10 00 mi as read as read as real as read as read as read as read u remi as read as read Ute floundary Dist nce sector P 0.73 mi

7. 3 E + 04 5.5E + 04
1. l E + 04 3 7E+00 3.6 E + 00 3.4 E + 00 3.3 E + 00 5.2 E+ 01 2.6E + 01 7.8E + 00 Special Receptors Bisir 3.22 mi 6.4E4 04 4.8E+ M
9. 6E+ 03 2.0E + 00 2.0E + 00 1.8 E +00 1.8 E+ 00 4.2E+ 01 2.lE + 0!

6.3 E + 00 Emergency Monitonne Points F1 0.30 mi 3.0E + 06 2.2E+ 06 4.5E+ 05 1.8 E + 02 1.8E+02 1.6E+ 02 1.6E+02 2.5E+ 03 1.3E + 03 3.tE+02 P2 1.20 mi 1.7E + 03 1.3 E + 03 2.6E + 02 as real as read as read as read as reed as read as real P4 1.80 ed 3.5E + 04 2.6E + 04 5.3 E + 03 1.1 E + 00

1. I E + 00 1.0E + 00 1.0E+ 00 2.3E+ 0!

1.lE+ 01 3.4E + 00 Note: The volume of air used in these calculations in 10 ft).

  • Controllerlevaluator reference data only.

EXERCISE \\EQUIPNE.XLS 7-43 Rev. 6/9/93

STATE OF NEI3RASKA 5 '"

FIELD TEAM EQUIPMENT TIME:

1100 - 1115 E.520 / (HP.260 or HP.210T)

RO-2 Dime Rates E.520 / (HP 260 or HP 210T)

Beta Particulate (fiher)

(mR/hr)

Indme (certrsige)

Cont.

SH-4 1.5 inch 3 mch 3 inch 3 & 5 ft.

3 & 5 ft.

Cont.

5H-4 1.5 inch Centerline Maximums net cpm met epm netcom open closed open ch=cd net o m net epm net tym 2.00 mi 5 DE + 05 3.8E + 05 7.5 E + 04 1.6E + 01 1.6E + 0!

1.5 E + 01 1.5E+ 01 2.9E + 02 1.4 E + 02 4.3E4 01 3 00 mi i BE+05 1.3 E+ 05 2.6E4 64

_5 6E+00 5 6E+00 5.1 E + 00 5.1 E + 00

1. l E + 02 5 SE+01 1,7E + 01 4.00 mi 6.5 E + 04 4.9 E + 04 9.8 E + 03 2.2E + 00 2.2E+ 00 2.0E + 00 2.0E + 00 4.8E + 01 2.4E+ 0!

7.3E + 00 10.00 mi na read as read as med as read as real as read as read as real as read as rest Site floundarv Datance sector P 0.73 mi 5.9E+05 4.5E+ 05 8.9E+ 04 2,s E + 01

2. 8 E + 01 2.6E + 01 2.5 E + 01
4. l E + 02
2. l E + 02 6.2E+01 Special Receptors Blair 3.22 mi 7.8 E + 04 5.8E+04 1.2E+ N 2.5 E+ 00 2.5 E+ 00 2.2E+ 00 2.2 E + 00 5.l E + 0!

2.5E+ 01 7.6E+00 P.mereenev Monitonny Points P1 0.50 mi 7.0E + 05 5.2E + 05 1.0E + 05 4.4E + 01 42E+01 4.0E + 0i 3.9E + 01 5.8E4 02 2.9E+ 02 8.7E + 01 P2 0.60 mi 5.0E + M 3.7E + 04 7.4 E + 03 2.6E+ 00 2.6E + 00 2.4 E+ 00 2AE+00 3.8E+ 01 1.9E + 0!

5.6E+00 P4 3.20 mi 4.0E+ 04 3.0E + 04 6.0E + 03 1.3E + 00 1.3 E + 00 1.1E + 00

1. l E + 00 2.6E+0!

1.3 E+ 01 3.9E + 00 P5 3.70 ml 9.7E + 04 7.3 E+ 04 1.5E + 04 3.2E + 00 3.2E + 00 2.9E + 00 ' 2.9E+00 6.9E + 01 3.4E+ 01 1.0E +01 P6 4.30 mi as read as rees as read as read as read as read as read as read as read as ned Note: The volume of air used in these calculations is 10 fd.

i

)

  • Controller /esalustor reference data only.

EXERCISE \\EQUIPNE XIJ 7-44 Rev. 6/9/93 i

~

=

STATE OF NEBRASKA e of u FIELD TEAM EQUIPMENT TIME-1115 1130 E 520 / (llP 260 or HP-2107)

RO-2 Dose Raam E 520 / (HP 260 or HP-21UT)

Ik-ta Particulate (filter)

(mR!hr)

Iodine (cartridre)

Cent.

SH.4 1.5 mch 3 inch 3 inch 3 & 5 ft 3 & 5 ft.

Cont.

SH 4 1.5 meh remerline Maximums met <tm met erm net epm open ckwvi open clomt net epm net epm net epm 2.00 mi 5.2E+ 05 3.9E + 05 7.8 E + 04 1.7E + 01 1.7E + 01 1.6E + 01 1.5E+0!

3.0E+ 02 1.5E + 02 4.4E+01 3.00 mi 2SE+05

2. l E + 05 4.2E + M 8 9E+00 8 8E+00
8. l E+00 8 OE + 00 1.8E+ 02 8.8E+01 2.6E + 01 4.00 mi
1. lE + 05 8.4E+M l.7E+04 3.7E+ 00 3.7E + 00 3.4E+ 00 3.4E + 00 8.4E + 01 4.2E+ 0!

1.3 E+ 01 5.00 mi 4.3 E+ 04 3.2 E + 04 6.4 E+ 03 1.6E+ 00 1.6E + 00 1.4E + 00 1.4E+ 00 3.9E + 01 2.0E+ 01 5.9E + 00 10.00 mi as read as remi as read as read as read as read as read as read as read as rest V

1 Site floundary Distance sector P 0.73 mi 1.2 E + M 9,3 E + 03 1.9E + 03

1. l E + 00 8 2E.01
9. 8 E-01 7.7E-01 as read as read as read Special Receptors Blair 3.22 mi 1.8E+ 05 1.3 E + 05 2.6E+ N 5.7E + 00 5.6E + 00 5.2E+00
5. l E + 00 1.2E + 02 5 8E+0!

1.7E+01 Emerrenev Monitoring Points PI 0.50 mi 3.3 E+ 06 2.5E+ 06 4.9E + 05

2. ! E + 02
2. ! E + 02 1.9E + 02 1.9E + 02 2.9E +03 1.4 E + 03 4.3 E + 02 P2 0.60 mi as read as read as read as read as real as read as read as read as read as read P4 3.20 mi
1. !E+ 05 8.6E+ 04 1.7E + N 3.6E + 00 3.6E+ 00 3.3 E + 00 3.3E + 00 7 4E+0!

3.7E + 01 1 lE+01 P5 3.70 mi

9. 8E+ N 7.4 E + 04 1.5 E + 04 3.2E+ 00 3.2 E + 00 2.9E+ 00 2.9E + 00 6.9E + 01 3.5E + 01 1.0E+ 01 P6 4.30 mi as read as read as read as read as read es read a read as read as read as read Note: The volume of air used in these calculations in 10 (13.
  • Controller / evaluator refenace data only.

EXERCISE \\EQUIPNE.XLS 7-45 Rev. 6/9/93

STATE OF NEBRASKA 7 14 ELELD TEAM EQUIPMENT 1

11ME:

1830 - 1845 L520 / (HP.260 or HP-21(TT)

RO 2 Dose Rates E-520 / (HP-260 or HP-210T)

Heta Partsculate (fiher)

(mR/hr) lodine fcartruf ge)

Cont.

SH-4 1.5 inch 3 inch 3 inch 3 & 5 ft.

3&5fL Cont.

SH4 1.5 mcb Centerline Maximume net epm net om net epm open closed open closed net epm met epm met epm 2 00 mi 3.9E + 05 3.0E+ 05 5.9E + 04 65E01 3.0E.01 5.9501 3.0501 2.2E+02 1.1E + 02 3.4 E + 01 3.00 mi 2,6E + 05 19E + 05

3. 8 E + 04 8 3E+ 00 8, l E + 00 7.6E + 00 7.4E + 00 1.6E+ 02 7.8E+01 2.4 E + 01 4.00 mi 1.6E + 05 1.2E + 05 2.3E+04 5.2 E + 00 5.2 E + 00
4. 8E + 00 4.7E+ 00 1.1E + 02 5.7E+ 01 1.7E + 01 5.00 mi 6 9E+04 5.1 E+ 04 1.0E+ 04 2.5 E+ 00 2.5E + 00 2.3 E + 00 2.3 E+ 00 6.1E + 01 3.1E+ 01 9.2E + 00 6.00 mi
2. 8E + M
2. l E + 04 4.1 E + 03 1.2E + 00 1.2E+ 00
1. l E + 00
1. l E + 00 3.1 E+ 01 1.5E+01 4.6E + 00 10.00 mi as read as read as read as read as read se read as read as read as read as read Site floundarv Distance occtar P 0.73 mi 9.3 E + 03 7.0E + 03 1.4 E + 03 9.0501 l 6.7E-01 8.2601 6.2D01 as read as read as read I

special Receptors Blair 3.22 mi 2.0E + 05 1.5 E + 05 3.0h + 04 6.4 E+ 00 6.3 E+ 00 5.8 E+ 00 5.7E + 00 1.3 E + 02 6.3E+01 1.9E+01 Emerrency Monitoring Points PI 0.50 mi 2.7E + 06 2.0E+ 06 4.0E + 05 1.8 E + 02 1.8 E + 02 1.6E + 02 1.6E+ 02 2.4E+03 1.2E+03 3.6E+ 02 P2 0.60 mi as read as read as read as read as read as read as need as read as read as read P4 3.20 mi 1.5E+ 05

1. lE+ 05 2.2 E+ N 4.7E + 00 4.7E + 00 4.3 E+ 00 4.3 E+ 00 9.3E+0i 4.6E+ 01 1.4E + 01 P5 3.70 mi 9 4E+05
7. lE + 05 1.4 E + 05 3.0E+ 00 3.0E + 00 2.8 E + 00 2.8E+ 00 6.5 E+ 01 3.2E+ 0!

9.7E+ 00 P7 6.80 mi 1.4 E+ 04 1.0E + 04

2. l E + 03 6.5E01 6.50-01 6.0501 6.0E01 1.9 E + 01 9.5 E + 00 2.83+ 00 Q3 2.50 mi na read as read as read as read as read as read as read as read as read as read i

1 Note:The volume of air used in these i

calculations is 10 ft3.

i I

1 l

  • Controlicr/ evaluator reference data only.

i 1

EXERCISE \\EQUIPNE.XLS 7-46 Rev. 6/9/93

STATE OF NEBRASKA 8 "

FlELD TEAM EQUIPMENT 11 mea 1845 1200 5520 / (HP-260 or HP.210T)

RO.2 Duse Rates L520 / (HP-260 or HP.210T)

Beta Particutste (filter)

(m3Uhr) lodine (cartrid e) t Cont SH-4 1.5 inch 3 inch l 3 inch 3 & 5 ft.

3&5fl Coat SH-4 1.5 inch Centerime Matimums act cpm met cpm met epm open I closed open chmed net cpm net cpm net epm 2.00 mi 3.4 E + 05 2.5E+ 05

5. lE+ 04
1. l E + 01
1. l E + 0!

9.8 E + 00 9.6 E + 00 7.0E + 02 09E+01 3.0E+ 01 3 00 mi 2.0E+ 05 1.5E+05 3.0E + 04

3. 7E + 00 3.6 E + 00 3.4 E + 00 3 3E+00 1.3E+#

6 6E+01 2.0E+ 01 4 00 mi

1. l E + 05 8.0E+04 1.6E + M 1.7E + 00 1.7E+ 00 16E+ 00 1.5E + 00
8. 8 E + 0 !

4.4 E + 0i 1.3 E + 01 5.00 mi 4.3E+M 3.2E + 04 6.5 E + 03 1.3 E + 00 1.3 E+ 00 1.2E + 00 1.2E+ 00 4.6E+ 01 2.3E+ 01 6.8E+ 03 6.00 mi 2.5 E+ 03 1.9E + 03 3.7E + 02 as read as read as read as read as reed as read as red 10.00 mi as read as read as read as read as read as read as read as read as read as read Site lioundarv Datance sector P 0.73 mi as read as read as read 3.8E01 l 1.7E01 f' 3.4E01 1.7E01 as read l es read as read sector B 0.74 nd 1.5 E + 03 1.!E+ 03 2.3 E + 02 as read ] as read as read as read as read I as read as read

$pecial Receptors Blair 3.22 mi as read as read as read 1.6E01 7 5E02 1.5E01 7.5E02 as read as read as read Emergenev Monitonar Points B1 0.06 mi 4.5 E + 07 3.4 E + 07 6.8 E + 06 1.6E + M 1.7E + 04 1.5 E + M 1.5 E + M 1.9E + 05 9.7E + 04 2.9E + 04 P1 0.50 mi as read as read as read 4.7E + M 4.7E+ M 4.3 E4 04 4.3 E + 04 as read as read as read R.1 2.30 mi 2.6E+05 2.0E + 05 4 OE+04 8.3 E + 00 8.3 E+ 00 7.5E + 00 7.5 E + 00 1.6E + 02 7.9E+0!

2.4 E+ 01 Q6 5.70 mi 3.8 E + 04 2.9E + 04 5 8 E + 03 1.7E+ 00 1.7E+00 1.6 E + 00 1.6E + 00 48E+01 2.4E+0!

7.2E+ 00 l

l i

l h

l Note: The volume of air used in these calcidations is 10 ft3.

i

  • Controllerlevaluator reference data only.

l EXERCISE \\EQUIPNE.XLS 7-47 Rev. 6/9/93 l

l

a STATE OF NEBRASKA 8 "' "

FIELD TEAM EQUIPMENT

^

TIME:

1200 - 1215 5520 / (HP-260 or HP-210T)

RO-2 Dose Rates b520 / (HP.260 or HP.2101)

Bean Pneuculate fiher) imR!hr) todine (cartruf re) r l 3 & 5 ft.

3 & 5 ft.

Cont.

SH-4 1.5 mch Cont SH-4 1.5 mch 3 mch 3 mch Centerbne Maumums met epm nee epm met epm open closed I

open closed net epm net epm net epm 2.00 nu 3.2E4 05 2.4 E + 05

4. 8E+ 04 1.0E + 01 1.0E + 01 9.5E + 00 9.3E + 00 1.8 E + 02 9.2E + 01 2.7E+01 3.00 mi
1. I E + 05 8 2E+04 1.6E + 04 3.4 E + 00 3.3 E+ 00
3. l E + 00 3.0E + 00 7 7E+0!

3.8E+0!

1.2E + 01 4 00 mi 8 6E+04 6.4E + 04 1.3E4 04 1.6E+ 00 1.6E+ 00 1.5 E + 00 1.5 E + 00

8. l E + 0!
4. l E+ 0!

1.2E + 01 5.00 mi 3.6E + G6 2.7E + 04 5.5 E + 03

1. l E + 00 1.1 E + 00 9.9001 9.9501 4.5E + 0!

2.3 E+01

6. 8E + 00 6 00 mi 2 0E+ 44 1.5E + 04 3.0E + 03 2.3L01 2.3L01 2.lE 01 2.IE 01 3.3E+0!

1.7E + 0!

5.0E+00 10 00 mi na read as read as med as read as reed as nad as read as read as read as read l

%te Doendarv Datance sector B 0.74 mi 3.6E + 04 2.7E + 04 l 5.5E+ 03 3 4E+00 j 3.4E + 00 3.lE+ 00 l 3.lE+00 2.5 E + 0!

1.3 E+ 0!

3.8E + 00 sector P 0.73 mi as read as read l me read I 70 + 00 l 1.5 E + 00 1.6E + 00 1. 1.4 E+ 00 as read as read as read Special Receptors Blaw 3.22 mi as read a read w read 1.50-01 1.5L01 1.3E-01 1.3501 as read as read as read Emerrency Monitonne Points A2 2.10 mi es read as read as read as read as read as read as read as ned as read as read B1 0.06 mi as read as read as read I. l E+ 02 5.lE+ 01 1.0E+ 02

5. lE + 01 as read as read -

as read B3 2.00 mi es read as reed as read as read as read as read as read as read as read as read P1 0.50 ad as reed as read w read 4.3 E + 00 1.9E + 00 3.9E + 00 1.9E + 00 na read as read as med Q7 6.70 mi 8 4E+03 6.3 E+ 03 1.3 E + 03 5.2001 5.2601 4.8501 4.8501 1.7E+ 01 8.4 E + 00 2.5E+ 00 Note: The volume of air used is these calculanons is 10 ft).

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPNE.XLS 7-48 Rev. 6/9/93

4 STATE OF NEBRASKA 10 "

FIELD TEAM EQUIPMENT

'I1ME:

1215 - 1230 E520 / (HP-260 or HP 210T)

RO.2 Dose Rau:s E520 / (HP 260 or HP-2101) heta Particulate (Giter)

(mRAr)

Indme (cartridre)

Cent, SH 4 1.5 mcb 3 mch 3 mch 3 & 5 ft 3 & 5 ft.

Cent SH-4 1.5 mch Centerline Maximums nee epm net rpm net epm open closed open closed net epm net epm act epm 2.00 mi 2.5 E + 05 1.9E+ 05 3 BE+04

8. lE+ 00 7.9E + 00 7.4 E + 00 7.2E + 00 1.3 E + 02 6.5E+0!

.9E+01 5 00 mi 6.2E+ 04 4 6E+04 9.3E + 03 1.9E + 00 1.8E + 00 I BE+00 1.7E + 00 3.9E401 1.9E + 01

$ BE+00 4.00 mi 6 8E+N 5.1F + 04 1.0E + 04 1.7E + 00 1.7E + 00 1.6E + 00 1.6E + 00 6.4 E + 01 3.2E + 01 9.62400 5 00 mi 2.8 E+ 04

2. lE+ 04 4.3 E+ 03 1.4 E + 00 1.4E+ 00 1.3 E+ 00 1.3 E +00
4. l E + 01 2.0E+ 01 6.iF + 00 6 00 mi 1.8 E + 04 1.3 E + 04 2.7E + 03
1. l E + 00 1.l E+ 00 9.7E01 9.7E01 3.4E+01 1.7E + 01 5.1E+ 00 l

8,00 mi as read as read as read as read as read as read as ned as read as read as read 10 00 mi as read as read as read as read as read as read as read as read es read as read P

site lloundarv Distance sector B 0.74 mi as read as read as read as read as read as read as read as read as read as read sector P 0,73 nd as read as read as read 3.2501 1.4 E01 2.9501 1.4501 as read as read as read

%pecial Receptors Blair 3.22 mi na read as read as read 1.3 DOI 6 OE02 1.2E.01 6.0502 as read

~ so read as read Emergency Monitoring Points B1 0.06 mi as read as read as read 1.0E + 02 4 6E+01

9. l E + 01 4.6E + 01 as read as read as read B2 1.90 mi
1. l E + 05 8.3 E + 04 1.7E + 04 3.6E+00 3.6E+ 00 3.3 E+ 00 3.3 E + 00 6.2E + 01 3.E+01 9.3E+ 00 IM 3.20 mi 1.7E + 05 1.3 E + 05 2.5E+ 04 5.3E + 00 5.3 E + 00 4.8 E+ 00 4.8 E+ 00
1. l E + 02 S.5E+ 01 1.6E + 01 PI 0.50 mi as read as read as read 3.9E + 00 1 BE+00 3.5E+ 00 1.8 E + 00 as ned as read as read R5 4.50 mi 5.4E + 04 4.0E+N
8. l E + 03 2.3 E + 00 2.3 E + 00 2.1 E + 00
2. l E + 00 6.2E+ 01 3.lE+01 9.3E + 00 R6 5.20 mi 4.2E+ 03

?.2E + 03 6.3E + 02 2.2E01 2.2601 2.0E 01 2.0E01 as med as read as read R7 6.20 mi 6.4E+ 03 4 PE+03 9.6E+02 4.2601 4.2E.01 3.8 E-01 3.8601 as read as read as read 6

Note: The volume of air used in these calculations is 10 ft).

  • Controller! evaluator reference data only.

EXERCISE \\EQUIPNE.XLS 7-49 Rev. 6/9/93

I STATE OF NEBRASKA 1 *' 1 '

FIELD TEAM EQUIPMENT 71ME 1230 1245 L520 / (HP.260 or HP-210T)

RO-2 Dame Estes 6520 / (HP-260 or HP-2107)

Beta Particulate (fiker)

(mR%r) 1%ine (cartridge)

Cont.

5H-4 1.5 ish 3 irwh 3 mch 3 & 5 ft.

3&5fl Cont SH-4 l 1.5 inch Centerline Mnimums net epm nrt epm nes epm open ch ad open cled met corn net epm I net epm 2.00 nu 9.8E+N 7.4E+ 04 1.5E+ 04 3 2E+00 3 OE+00 2 9E+00 2.7E+ 00 5.5 E+ 01 2.7E + 01 8.2E+ 00 3.00 mi 6 9E + 04 5 2E+04 1.0E+ 04 21E+ 00 2.1 E + 00 2.0E + 00 19E+ 00 4.2E+ 01 2.1E+ 01 6 3E+ 00 4 00 mi 9.4 E + 04 7.0E + 04 1.4E+N 3.1 E + 00 3.lE+ 00 2 8E+ 00 2.8E+ 00 6.8 E + 01 3.4 E + 01 1.0E+ 01 5.00 mi 2.5E + N 1.9E + 04 3.8E+ 03 1.8E+ 00 1.8 E + 00 1.7E + 00 1.7E + 00 4.9E + 01 2.4E + 01 7.3 E + 00 l

6 00 mi 9.4E + 03

7. l E + 03 1.4 E+ 03 1.2E + 00 1.2E + 00
1. l E + 00 f. l E + 00 3.9E + 01 2.0E + 01 5.9E + 00 8.00 mi 3.6E + 03 2.7E+ 03 5.5 E + 02 3.7EDI 3.7L01 3.4001 3.4E-01 as read as read as read 10 00 mi as read as read as ned as read as read e real as read as read as read as ned Site Doundary Distance sector B 0.74 mi as read as read as read as read as r vf l 2.7EDI j as reed as read as read as read as read sector P 0.73 mi as read as read as read 2.9501 1.4601 l

l 1.4 E.01 as read as read as read Special Receptors Blair 3.22 nu as read as ned as read 1.2001 1.4E + 00 1.1601 1.4 E + 00 as read as read as read Emergency Monitoring Points A3 5 90 mi as read as read as read a read as read as read as read as read as read as read A5 6 30 mi as read as read as read as read as read as real as read as read as read as read B1 0.06 mi as read en read as read 9.1 E + 01 4.2E+ ct 8.3 E+ 01 4.2E + 01 as real es read as read B2 1.90 mi 2.4 E + 05 1.8E+ 05 3.6E+ N 8.0E+ 00 7.9E+ 00 7.3 E + 00 7.2E+ 00 1.3E + 02 6.7E+ 01 2.0E+0!

B5 3.90 mi 6.2E+ 04 4.6E+ 04 9.3 E+ 03 2.0E + 00 2.0E+ 00 1.8 0 + 00 1.8 E+ 00 4.4 E + 0!

2.2E + 01 6.6E+ 00 Cl 0.06 mi as read as read as read as read as ned as read as read as read as read as nad P1 0.50 mi as re=1 m read a read 3.5 E + 00 1 6E+ 00 3.2 E + 00 1.6E+ 00 as read as read as read R8 7.70 mi 2.2 E+03 1.7E + 03 3.3 E+ 02 2.0501 20001 1.8L01 1.8E-01 en read as read as read R9 8.10 mi 3.5E+ 03 2.6E+03 5 3E+02 3.7L01 3.7 DOI 3.3601 3.3601 as ned as read as nad

[

Note:Thr. volume of air used in these cakulations is 10 ft).

  • Controllerlevaluator reference data onJy.

EXERCISE \\EQUIPNE.XLS 7-50 Rev. 6/9/93

a STATE OF NEBRASKA 12 of 14 FIELD TEAM EQUIPMENT 11ME:

1245 1300 5520 t (HP-260 or HP.210T)

RO.2 Done Raus L520 / (HP.260 or HP.210T)

Beta Particulate (fiher) imR'ht)

Iodme (ca trwige)

Cont SH-4 l

1.5 inch 3 erh 3 inch 3 & 5 ft. [ 3 & 5 ft.

Cont

{

SH-4 15 inch Centerhne Maximums net epm net epm I net om apen cimed open I chaaf net epm I net epm net epm 2.00 mi 9.6E + M 7.2E4 04 1.4E+04

3. l L + 00 2 9E+00 2.9E + 00 2.7E + 00 5.4 E + 01 2.7E+ 01 8.0E + 00 3 00 mi 4.7E+04 3.6E + 04
7. l E + 03 1.5E + 00 1.4 E+ 00 1.4 E + 00 13E+00 28E+01 1.4E + 01 4.3 E + 00 4 00 mi 3 OE+ 04 2.2E+ 04 4.5E+ 03 9.8601 9.8601 9.0001 9.0001
2. l E+ 01 1.1 E+ 01 3.2E + 00 5.00 mi 4.9E + 04 3.7E + 04 7.3 E + 03
1. 8 E + 00 1.8E+ 00 1.6E+ 00 1.6E + 00 4.3 E+ 01 2.2E + 01 6.5E + 00 6 00 mi 2.7E+ 04 2.0E+ 04 4 0E+03 1.4 E + 00 1.4 E + 00 1.2 E + 00 1.2E+ 00 4.0E+ 0!

2.0E + 01

6. l E + 00 8.00 mi 4 9E+03 3.7E + 03 7.4E+ 02 5.3001 5.3 DOI 4.8501 4.8L01 2.0E+ 01 1.0E+ 0!

3.0E + 00 10 00 mi as read as read u nad a read as read as read u read u read as read

=a read Site lloundarv Datance sector B 0.74 mi as read as read I as read as read as read j

l as read u read as read as read se read f as read 2.7L01 1.2501 1 2.5E-01 l 1.2001 as read as read as read sector P 0.73 nu as read as read Special Receptora Blair 3.22 mi as read as nad as read as read as read as read as rewi as read as read as read Emergency Manitonne Points A3 5.90 mi e read as nad as read as read as read as read as read as read as nad a read A4 6.00 mi 2.4E+ 04

1. 8 E + 04 3.7E + 03 1.3 E+ 00 1.3E+ 00 1.2E+ 00 1.2E+ 00
3. 8E+ 0!

1.9E + 0!

5.7E+00 A5 6.30 mi 2.0E + 03 1.5 E + 03 3.0E+ 02 1.5Lol 1.5 L01 1.3 L01 1.3601 as read as read as ned A6 1.05 mi 5.2E + 03 3.9 E+ 03 7.7E+ 02 3.2L01 3.2L01 2.9E.01 2.9601 as read as read as read B1 0.06 mi as read as read as read 8.3E+ 01 3.8E+0!

7.6E+ 01 38E+01 as ned as read a read B2 1.90 mi

2. l E+ 05 1.6E+ 05
3. l E + 04 7.1 E + 00 7.0E + 00 6.4 E+ 00 6.4 E + 00 1.2E+02
5. BE+ 01 1.7E + 0!

IW 3.20 mi as read as read as read as read as read as read as read as read as read as nad B5 3.90 mi

8. lE+ 04 6 0E+04 1.2 E+ 04 2.6E+ 00 2 6E+ 00 2.4E + 00 2.4E + 00 5.6E+0!

2.8 E + 0!

8.4E+ 00 D6 5.30 mi 4.6E + 04 3.4E+04

6. 8 E + 03 as nad as read as read as read 4.3 E+ 01 2.lE+ 01 6.4b+ 00 B7 6.50 mi as read as read as read as read as read as read as read as read as read as read P1 0.50 mi as read as read as read 3.3E + 00 3.3E+ 00 3.0E+ 00 3.0E + 00 as read as read as read R8 7.70 ud as read as read as read a read as read as read me read as read as read as read Note: The volume of air used in these calculations is 10 ft3.

I

  • Controller / evaluator reference data only, EXERCISE \\EQUIPNE.XLS 7-51 Rev. 6/9/93

4 STATE OF NEBRASKA 13 ' ' '

FIELD TEAM EQUIPMENT TIME:

1300 - 1315 L520 / (HP-260 or HP-210T)

RG2 Done Rates 5520 / (HP 260 or HP-210T)

Beta Partx;wlete (fdter)

(mR.%r)

Iodme (cartridre) 3 & 5 ft l 3 & 5 ft Cont.

5H-4 1.5 inch 3 inch 3 inch Cant.

SH4 1.5 inch Centertme Maximums net cpm met cpm act epm open closed open cl<end act epm net epm net epm 2 00 mi 6 9E + 04 5.2E +04 1.0E +04 2.4 E +00 2.2E + 00 2.2E +00 2.0E +00 3.9E +01 1.9E+ 01 5.8E+00 3.00 mi 3.7E + 04 2.7E + 04 5.5 E + 03

1. l E + 00
1. lev 00 1.0E+ 00 9.7EDI 2.2 E+ 01
1. l E + 01 3.3 E + 00 4.00 mi
2. l E+ 04 1.6E+ 04
3. l E+ 03 6.8L01 6 BE-01 6.2501 6.2E-01 es red as read as read 5.00 mi 1.0E+ 04 7.6E+ 03 1.5E + 03 6.4001 6,4501 5.8001 5.8E-01 as read a read as read 6.00 mi 1.8 E + 04 1.3 E + 04 2.7E + 03 8 9L01 8.9E-01
8. l E-01 8.1001 2.3 E+ 01 1.2E+ 01 3.5 F + 00 8.00 mi 7.9E+ 03 6.0E + 03 1.2E + 03 7.5E-01 7.5001 6 BLOX 6.8501 2.8E+ 01 1.4E+ 01
4. l E + 00 10 00 mi u read as read as read as read as read as read as read as read as read as read

%te Dounderv Datance sector B 0.74 mi as read as read l as read as read l as read l no read l as read as read as read l es read sector P 0 73 mi as read as read j as read 2.5001 l 1.2001 l 2.3001 l 1.2501 as read as read l ns read Specist Receptors Blau 3.22 mi as read as read as read u read as read as red as read as read as red as read Modale 7.74 mi as read as read as read as read as read as read as read as need as ned as read t.

rrency Monitoring Points A6 1.05 mi as read as read as read as read as read as read as read as ned as nad as read A7 7.80 mi 9.0E+ 03 6.7E + 03 1.3 E+ 03 7.7501 7.7E-01 7.0001 7.0001 2.7E+ 01 1.4 E + 01 4.1 E+ 00 A9 8.80 mi 1.4 E + 03 1.0E+ 03

2. l E + 02 1.5501 1.5L01 1.4501 1.4 E-01 es read as read as reed 81 0.b6 mi as read as read as read 7.7E+ 0!

3.5E + 01 7.0E + 01 3.5E+01 as re=1 as read as ned B2 1.90 mi 1.0E + 05 7.8E + 04 1.6E+04 3.7E+ 00 3.5 E + 00 3.3E + 00 3.2E + 00 5.8E+ 01 2.9E4 01 8.7E + 00 D4 3.20 mi as read as read as read u read as read as read as read as read as read as nad B5 3.90 mi 6.5 E + 04 4.9E + 04 9.7E + 03

2. l E + 00 2.l E + 00 1.9E+00 1.9E+ 00 4 4E+01 2.2E + 01 6.6E + 00 14 5.30 mi 3.0E+ 04 2.2E + 04 4.5E + 03
1. l E + 00
1. l E + 00 1.0E+ 00 1.0E+00 2.7E + 01 1.4E+ 01 4.1 E + 00 B7 6.50 mi 5.2E+ 03 3.9E + 03 7.9E+ 02 2.5E-01 2.5001 2.2501 2.2001 as read as read as read B8 7.80 mi es read as read as read as read as read u read as read as read as read as read P1 0.50 mi as read as resw!

as read 3.0E+ 00 1.4 E+ 00 2.8 E+ 00 1.4 E + 00 se read as read as read Note:The volume of air used in these calculations is 10 ft3.

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPNE.XLS 7-52 Rev. 6/9/93

l e

STATE OF NEBRASKA FIELD TEAM EQUIPMENT 11ME:

1315 1330 L520 / (HP.260 or HP-2107)

RO-2 Duee Rates L520 / (HP.260 or HP.2101) flete Perth,dnte (fiher)

(mRk) lod me (certridge)

Cont.

SH-4 1.5 nwh 3 inch 3 mwh 3 & 5 ft.1 3 & 5 It Cont SH-4 1.5 inch Centerline Maximums net epm net epm nca epm open ekwed open claned met epm net om net com 2.00 mi

4. 8 E + 04 3.6E + 04 7.2E+ 03 1.7E+ 00 1.5E+ 00 1.6E + 00 1.4 E+ 00 2.7E+01 1.3 E + 01 4.0E+ 00 3 00 mi 5.7E+04 4SE+N 8.5 E + 03 1.8 E + 00 17E+ 00 1.6E + 00 1.6E + 00 3.4 E+ 01 1.7E+ 01 5.1 E + 00 4 00 mi 3.7E + N 2 8E+04 5 6E+03 1.7001 1.7L01 1.5L01 1.5L01 2.5E + 01 1.3 E+ 01 3.8 E + 00 5 00 mi 2OE+N 1.5 E + N
3. I E + 03 7.2601 7.2LOI
6. 6E-01 6.6Lo!

1.7E+ 01 8.4 E + 00 2.5E + 00 l

6 00 ma 1.3E+ 04 94E+03 1.9E + 03 5.1501 5.1001 4.6L01 4 6 LOX as read as read as read 8 00 nu 1.4E+ 04

1. lE+ 04 2.2E + 03 8.1501 81601 7.4LOl 7.4 LO!

2.5E+01 1.2E+ 01 3.7E + 00 10.00 mi 2.0E + 03 1.5E + 03 3 OE+02 33001 3.3 DOI 3.0501 3 OLOI as read as read es read Site Hounderv Datance eedor 11 0.74 mi 6.5E + 03 4 8E+03

9. (E+ 02 3.3E-01 3.3601 3.0E-01 ~ 3.0501 as ned as read as read sector P 0.73 mi es read as read as read 2.4 LOX 11001 2.2E-01
1. lL01 as read as read as ned Special Reccpenrs Bimir 3.22 mi as read as read as read as read as read u read as read as read as read as read Modele 7.74 ma 1.3 E+ 04 9 4E+03 1.9E + 03 6 9L01 6.9501 6.2L01 6.2001 as read as read as read Emergenev Morntonne Points At 8.00 mi 1.3 E+ 03 9.5E + 02 1.9E + 02 as read as read as read as read as read as reed as read A9 8 80 mi as read as read as reed as read as read me read as read as read as read as ned A10 9 20 mi 1.3 E + 03 9.5E + 02 1.9E + 02 49001 4.9501 4.5LCl 4.5LOI
1. 9E + 01 9.5E+00 2 SE+00 B1 0 06 mi as read as read as read
7. l E + 01 3.2E+01 6.5E+ 01 3.2E+ 01 as read as read as read B2 1.96 mi 1.2E+ 04 9.0E+ 03 1.8E+ 03 6.0LOI 4.9001 54LOI 4.5LC1 na read as read as read fu 3.20 mi en read as read as read en read as read as ned as read as read as read as res4 B5 3 90 mi 6.l E + 04 4 6E+04
9. lE+ 03 2,0E + 00 2.0E+ 00 1.8 E+ 00 1 8E+ 00 4tE+0!

2.0E4 01 6.1 E+ 00 IM 5.30 mi 2.8 E + 04

2. l E + 04 4.2E + 03 1.0E+ 00 1.0E + 00 9.5LO!

9.5 LOX 2.5E+ 01 1.2 E + 01 3.7E + 00 B7 6.50 mi as read as read as read en read as reed as nad as read as reed as read as read B8 7.80 mi 4.5 E + 03 3.4E + 03 6 BE402 2.7L01 2.7001 2.4L01 2,4501 as read as read as read B9 8 40 mi 9 6E+ 03 7.2E+ 03 1.4E+03 68001 6.8601 6.2601 6.2501 2.3E+0!

1.lE + 01 3.4E+00 P1 0.50 mi se read as read m read 2 BE+00 1.3E+ 00 2.6E + 00 1.3 E+ 00 as ned as read a read Note: The volume of air used in these calculations is 10 ft3.

l

  • Controller / evaluator reference data only.

EXERCISE \\EQUIPNE.XLS 7-53 Rev. 6/9/93 i

..